{"id":"https://openalex.org/W2980291626","doi":"https://doi.org/10.1109/ccece.2019.8861532","title":"Magnetic Saturation in Synchronous Generator Dynamic Models for Power System Stability Studies","display_name":"Magnetic Saturation in Synchronous Generator Dynamic Models for Power System Stability Studies","publication_year":2019,"publication_date":"2019-05-05","ids":{"openalex":"https://openalex.org/W2980291626","doi":"https://doi.org/10.1109/ccece.2019.8861532","mag":"2980291626"},"language":"en","primary_location":{"id":"doi:10.1109/ccece.2019.8861532","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2019.8861532","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE Canadian Conference of Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021100967","display_name":"Quincy Y. Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I118189293","display_name":"BC Hydro (Canada)","ror":"https://ror.org/01x6ma944","country_code":"CA","type":"company","lineage":["https://openalex.org/I118189293"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Quincy Y. Wang","raw_affiliation_strings":["Reliability Compliance, BC Hydro and Power Authority, Burnaby, BC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Reliability Compliance, BC Hydro and Power Authority, Burnaby, BC, Canada","institution_ids":["https://openalex.org/I118189293"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100413239","display_name":"Yunfei Wang","orcid":"https://orcid.org/0000-0001-9046-2150"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yunfei Wang","raw_affiliation_strings":["Power System Studies, AltaLink Management Ltd., Calgary, AB, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power System Studies, AltaLink Management Ltd., Calgary, AB, Canada","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"48","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.7681548595428467},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7618229389190674},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.7497707605361938},{"id":"https://openalex.org/keywords/saturation","display_name":"Saturation (graph theory)","score":0.6592986583709717},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.5539844036102295},{"id":"https://openalex.org/keywords/salient","display_name":"Salient","score":0.5506177544593811},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.536062479019165},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.48138001561164856},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.4572242796421051},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.44070902466773987},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.43612009286880493},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.371826708316803},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2934871315956116},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.22394275665283203},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.18318286538124084},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10918471217155457}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7681548595428467},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7618229389190674},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.7497707605361938},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.6592986583709717},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.5539844036102295},{"id":"https://openalex.org/C2780719617","wikidata":"https://www.wikidata.org/wiki/Q1030752","display_name":"Salient","level":2,"score":0.5506177544593811},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.536062479019165},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.48138001561164856},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4572242796421051},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.44070902466773987},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43612009286880493},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.371826708316803},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2934871315956116},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22394275665283203},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.18318286538124084},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10918471217155457},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccece.2019.8861532","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2019.8861532","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE Canadian Conference of Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1763243278","https://openalex.org/W2417494423","https://openalex.org/W2905070660","https://openalex.org/W4251493252","https://openalex.org/W6717116524"],"related_works":["https://openalex.org/W623794290","https://openalex.org/W2329500892","https://openalex.org/W2372255233","https://openalex.org/W2361693169","https://openalex.org/W2130828945","https://openalex.org/W2360961134","https://openalex.org/W2350949866","https://openalex.org/W2382327273","https://openalex.org/W1989707656","https://openalex.org/W3010211530"],"abstract_inverted_index":{"This":[0],"article":[1],"analyzes":[2],"and":[3,29,35,53,84,91],"compares":[4],"the":[5,9,57,102],"magnetic":[6],"saturations":[7],"of":[8,44,70,97,101],"synchronous":[10,31],"generator":[11,40,58],"dynamic":[12,41],"models":[13],"commonly":[14],"used":[15],"for":[16,26,37,105],"power":[17],"system":[18],"stability":[19],"studies.":[20],"A":[21],"simple":[22],"saturation":[23,48,103],"method":[24,104],"suitable":[25],"both":[27,51],"round-rotor":[28,90],"salient-pole":[30,92],"generators":[32,93],"is":[33,61,79],"introduced":[34],"evaluated":[36],"high":[38],"accuracy":[39,68],"models.":[42],"Feasibility":[43],"applying":[45],"a":[46,95,106],"single":[47],"factor":[49],"to":[50,75],"d-":[52],"q-axis":[54],"in":[55],"determining":[56],"rotor":[59,77],"angle":[60,78],"studied":[62],"from":[63],"field":[64,85],"measurement":[65,86],"data.":[66],"The":[67,99],"improvement":[69],"using":[71],"saturated":[72],"stator":[73],"parameter":[74],"calculate":[76],"demonstrated":[80],"based":[81],"on":[82,88],"calculation":[83],"results":[87],"in-service":[89],"with":[94],"variety":[96],"capacities.":[98],"suitability":[100],"proposed":[107],"GENQSC":[108],"model":[109],"has":[110],"been":[111],"proved.":[112]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
