{"id":"https://openalex.org/W2644036878","doi":"https://doi.org/10.1109/ccece.2017.7946627","title":"A bus differential protection scheme using real-time synchrophasor data","display_name":"A bus differential protection scheme using real-time synchrophasor data","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2644036878","doi":"https://doi.org/10.1109/ccece.2017.7946627","mag":"2644036878"},"language":"en","primary_location":{"id":"doi:10.1109/ccece.2017.7946627","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2017.7946627","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 30th Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027294111","display_name":"Yujie Yin","orcid":null},"institutions":[{"id":"https://openalex.org/I99041443","display_name":"Mississippi State University","ror":"https://ror.org/0432jq872","country_code":"US","type":"education","lineage":["https://openalex.org/I4210141039","https://openalex.org/I99041443"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Yujie Yin","raw_affiliation_strings":["GE Grid Solutions, Mississippi State University"],"affiliations":[{"raw_affiliation_string":"GE Grid Solutions, Mississippi State University","institution_ids":["https://openalex.org/I99041443"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100756509","display_name":"Zhiying Zhang","orcid":"https://orcid.org/0000-0001-6982-4735"},"institutions":[{"id":"https://openalex.org/I99041443","display_name":"Mississippi State University","ror":"https://ror.org/0432jq872","country_code":"US","type":"education","lineage":["https://openalex.org/I4210141039","https://openalex.org/I99041443"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zhiying Zhang","raw_affiliation_strings":["GE Grid Solutions, Mississippi State University"],"affiliations":[{"raw_affiliation_string":"GE Grid Solutions, Mississippi State University","institution_ids":["https://openalex.org/I99041443"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041603535","display_name":"Yong Fu","orcid":"https://orcid.org/0000-0002-5150-8125"},"institutions":[{"id":"https://openalex.org/I99041443","display_name":"Mississippi State University","ror":"https://ror.org/0432jq872","country_code":"US","type":"education","lineage":["https://openalex.org/I4210141039","https://openalex.org/I99041443"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yong Fu","raw_affiliation_strings":["GE Grid Solutions, Mississippi State University"],"affiliations":[{"raw_affiliation_string":"GE Grid Solutions, Mississippi State University","institution_ids":["https://openalex.org/I99041443"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5027294111"],"corresponding_institution_ids":["https://openalex.org/I99041443"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.07317461,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.8696064949035645},{"id":"https://openalex.org/keywords/differential","display_name":"Differential (mechanical device)","score":0.6140154600143433},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.5979483723640442},{"id":"https://openalex.org/keywords/differential-protection","display_name":"Differential protection","score":0.5613660216331482},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.5556151270866394},{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.48202764987945557},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.47598209977149963},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4128047823905945},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.40299999713897705},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3786042630672455},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.31413477659225464},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.26762157678604126},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.16309002041816711},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.0990438163280487}],"concepts":[{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.8696064949035645},{"id":"https://openalex.org/C93226319","wikidata":"https://www.wikidata.org/wiki/Q193137","display_name":"Differential (mechanical device)","level":2,"score":0.6140154600143433},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.5979483723640442},{"id":"https://openalex.org/C2986957705","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Differential protection","level":4,"score":0.5613660216331482},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.5556151270866394},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.48202764987945557},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.47598209977149963},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4128047823905945},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40299999713897705},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3786042630672455},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31413477659225464},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.26762157678604126},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.16309002041816711},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0990438163280487},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccece.2017.7946627","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2017.7946627","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 30th Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1966806427","https://openalex.org/W1972358508","https://openalex.org/W2008443002","https://openalex.org/W2046085161","https://openalex.org/W2081356499"],"related_works":["https://openalex.org/W4205372965","https://openalex.org/W2572248349","https://openalex.org/W2150619725","https://openalex.org/W4229565825","https://openalex.org/W2118885789","https://openalex.org/W3214830231","https://openalex.org/W2950245028","https://openalex.org/W3189569452","https://openalex.org/W2157643825","https://openalex.org/W2910287997"],"abstract_inverted_index":{"The":[0],"common":[1],"form":[2],"of":[3,46,57,68,124],"bus":[4,49,94,110,121,132,138,147,157],"differential":[5,14,21,50,95,111,122,133,139],"protection":[6,24,51,112,148,158],"is":[7,31],"to":[8,42,107,128],"use":[9],"either":[10],"a":[11,17,26,64,154],"high":[12,44],"impedance":[13,20],"relay":[15],"or":[16],"biased":[18],"low":[19],"relay.":[22],"Bus":[23],"using":[25,113,125],"feeder":[27],"overcurrent":[28],"blocking":[29],"scheme":[30],"also":[32],"widely":[33],"used":[34,92],"in":[35,71,97],"the":[36,43,47,58,87,98,109,144],"sub-transmission":[37],"and":[38,101,149],"distribution":[39],"levels":[40],"due":[41],"cost":[45],"complete":[48,156],"solution.":[52],"IEEE":[53],"Working":[54],"Group":[55],"C-14":[56],"Power":[59],"System":[60],"Relaying":[61,73],"Committee":[62],"published":[63],"report":[65],"on":[66,75,105],"Use":[67],"Synchrophasor":[69],"Measurements":[70],"Protective":[72],"Application":[74],"April":[76],"8,":[77],"2013.":[78],"In":[79],"this":[80,119],"report,":[81],"it":[82,141],"was":[83],"pointed":[84],"out":[85],"that":[86],"synchrophasor":[88,126],"measurements":[89],"could":[90],"be":[91],"for":[93,146,153],"relaying":[96],"near":[99],"future":[100],"provided":[102],"some":[103],"guidelines":[104],"how":[106],"realize":[108,129],"phasor":[114],"measurements.":[115],"This":[116],"paper":[117],"studies":[118],"novel":[120],"technology":[123],"data":[127],"fast,":[130],"reliable":[131],"protection.":[134],"Together":[135],"with":[136],"other":[137],"protection,":[140],"can":[142],"satisfy":[143],"requirement":[145],"provide":[150],"an":[151],"option":[152],"low-cost":[155],"system.":[159]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
