{"id":"https://openalex.org/W1502976474","doi":"https://doi.org/10.1109/ccece.2015.7129404","title":"Remedial operations for open- and short-circuit faults of permanent magnet fault tolerant motor","display_name":"Remedial operations for open- and short-circuit faults of permanent magnet fault tolerant motor","publication_year":2015,"publication_date":"2015-05-01","ids":{"openalex":"https://openalex.org/W1502976474","doi":"https://doi.org/10.1109/ccece.2015.7129404","mag":"1502976474"},"language":"en","primary_location":{"id":"doi:10.1109/ccece.2015.7129404","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2015.7129404","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 28th Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024667104","display_name":"Binqiang Si","orcid":"https://orcid.org/0000-0003-3206-1388"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Si Binqiang","raw_affiliation_strings":["Beihang University Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","Beihang University, Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Beihang University Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"Beihang University, Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108248482","display_name":"Guangshang Zeng","orcid":null},"institutions":[{"id":"https://openalex.org/I4210120144","display_name":"Beijing Jingshida Electromechanical Equipment Research Institute","ror":"https://ror.org/02vx4zx98","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210120144"]},{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zeng Guangshang","raw_affiliation_strings":["Department of Computer Science and Technology Tsinghua University, Beijing, China","Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Department of Computer Science and Technology Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]},{"raw_affiliation_string":"Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","institution_ids":["https://openalex.org/I4210120144"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Zhu Jihong","orcid":null},"institutions":[{"id":"https://openalex.org/I4210120144","display_name":"Beijing Jingshida Electromechanical Equipment Research Institute","ror":"https://ror.org/02vx4zx98","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210120144"]},{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhu Jihong","raw_affiliation_strings":["Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","Dept. of Computer Science & Technology, Tsinghua University, Beijing, China#TAB#"],"affiliations":[{"raw_affiliation_string":"Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China","institution_ids":["https://openalex.org/I4210120144"]},{"raw_affiliation_string":"Dept. of Computer Science & Technology, Tsinghua University, Beijing, China#TAB#","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100317589","display_name":"Zongxia Jiao","orcid":"https://orcid.org/0000-0002-2395-2165"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiao Zongxia","raw_affiliation_strings":["School of Automation Science and Electrical Engineering Beihang University, Beijing, China","School of Automation Science and Electrical Engineering, BEIHANG University, Beijing, China#TAB#"],"affiliations":[{"raw_affiliation_string":"School of Automation Science and Electrical Engineering Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"School of Automation Science and Electrical Engineering, BEIHANG University, Beijing, China#TAB#","institution_ids":["https://openalex.org/I82880672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5024667104"],"corresponding_institution_ids":["https://openalex.org/I82880672"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.01884397,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"123","issue":null,"first_page":"953","last_page":"958"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.8470519185066223},{"id":"https://openalex.org/keywords/decoupling","display_name":"Decoupling (probability)","score":0.6152298450469971},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.5777987241744995},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.5483593940734863},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5237281918525696},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5094242691993713},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.48696956038475037},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.4593946635723114},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.445125550031662},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.44318100810050964},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3862673044204712},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33257541060447693},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.321328341960907},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2654832601547241},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.17678290605545044},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10896909236907959},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.10063081979751587},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09829264879226685},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.06183367967605591},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.047629356384277344}],"concepts":[{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.8470519185066223},{"id":"https://openalex.org/C205606062","wikidata":"https://www.wikidata.org/wiki/Q5249645","display_name":"Decoupling (probability)","level":2,"score":0.6152298450469971},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.5777987241744995},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.5483593940734863},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5237281918525696},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5094242691993713},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.48696956038475037},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.4593946635723114},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.445125550031662},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.44318100810050964},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3862673044204712},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33257541060447693},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.321328341960907},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2654832601547241},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.17678290605545044},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10896909236907959},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10063081979751587},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09829264879226685},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.06183367967605591},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.047629356384277344},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccece.2015.7129404","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2015.7129404","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 28th Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2005803264","https://openalex.org/W2015262331","https://openalex.org/W2057609201","https://openalex.org/W2058176059","https://openalex.org/W2073936063","https://openalex.org/W2114354981","https://openalex.org/W2132033583","https://openalex.org/W2165649830","https://openalex.org/W2171676254","https://openalex.org/W2382451386","https://openalex.org/W2540193160","https://openalex.org/W3178189436"],"related_works":["https://openalex.org/W4313561376","https://openalex.org/W3103825105","https://openalex.org/W3027880158","https://openalex.org/W1617565119","https://openalex.org/W160381218","https://openalex.org/W2512958550","https://openalex.org/W2004102934","https://openalex.org/W4366455350","https://openalex.org/W2329266651","https://openalex.org/W4321844193"],"abstract_inverted_index":{"Due":[0],"to":[1,20,28],"their":[2],"concentrated":[3],"windings":[4],"and":[5,16,22,25,47,51,55],"modular":[6],"topology,":[7],"permanent-magnet":[8],"fault-tolerant":[9,17],"(PMFT)":[10],"motors":[11],"inherently":[12],"offer":[13],"decoupling":[14],"phases":[15],"capability.":[18],"According":[19],"open-":[21],"short-circuit":[23],"faults,":[24],"in":[26],"order":[27],"keep":[29],"torque":[30],"performance":[31],"invariant":[32],"during":[33],"the":[34,56,59],"faulty":[35],"operation,":[36],"two":[37],"relevant":[38],"fault":[39],"tolerant":[40],"strategies":[41,57],"are":[42,61],"separately":[43],"presented,":[44],"derived,":[45],"analyzed":[46],"tested.":[48],"The":[49],"effectiveness":[50],"validity":[52],"of":[53,58],"fault-tolerance":[54],"motor":[60],"verified.":[62]},"counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2026-04-16T08:26:57.006410","created_date":"2025-10-10T00:00:00"}
