{"id":"https://openalex.org/W2004226086","doi":"https://doi.org/10.1109/ccece.2012.6334818","title":"Facts based fault current limiter utilization in HV grid","display_name":"Facts based fault current limiter utilization in HV grid","publication_year":2012,"publication_date":"2012-04-01","ids":{"openalex":"https://openalex.org/W2004226086","doi":"https://doi.org/10.1109/ccece.2012.6334818","mag":"2004226086"},"language":"en","primary_location":{"id":"doi:10.1109/ccece.2012.6334818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2012.6334818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 25th IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071520701","display_name":"Amir Golshani","orcid":"https://orcid.org/0000-0002-9292-0570"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]},{"id":"https://openalex.org/I80543232","display_name":"K.N.Toosi University of Technology","ror":"https://ror.org/0433abe34","country_code":"IR","type":"education","lineage":["https://openalex.org/I80543232"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"A. Golshani","raw_affiliation_strings":["Department of Electrical Engineering, K. N. Toosi University of Technology, Tehran, Iran","Department of Electrical Engineering, K.N.T. University of Technology, Tehran, Iran"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, K. N. Toosi University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I80543232"]},{"raw_affiliation_string":"Department of Electrical Engineering, K.N.T. University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033950685","display_name":"Alireza Khakpour","orcid":"https://orcid.org/0000-0003-2803-5283"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]},{"id":"https://openalex.org/I80543232","display_name":"K.N.Toosi University of Technology","ror":"https://ror.org/0433abe34","country_code":"IR","type":"education","lineage":["https://openalex.org/I80543232"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"A. Khakpour","raw_affiliation_strings":["Department of Electrical Engineering, K. N. Toosi University of Technology, Tehran, Iran","Department of Electrical Engineering, K.N.T. University of Technology, Tehran, Iran"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, K. N. Toosi University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I80543232"]},{"raw_affiliation_string":"Department of Electrical Engineering, K.N.T. University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054889817","display_name":"Lutz Hofmann","orcid":"https://orcid.org/0000-0002-3688-6136"},"institutions":[{"id":"https://openalex.org/I114112103","display_name":"Leibniz University Hannover","ror":"https://ror.org/0304hq317","country_code":"DE","type":"education","lineage":["https://openalex.org/I114112103"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"L. Hofmann","raw_affiliation_strings":["Institute of Electric Power System, Power Supply Division, Leibniz University, Hanover, Germany","Institute of Electric Power System, Power Supply Division, Leibniz University, Hannover, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electric Power System, Power Supply Division, Leibniz University, Hanover, Germany","institution_ids":["https://openalex.org/I114112103"]},{"raw_affiliation_string":"Institute of Electric Power System, Power Supply Division, Leibniz University, Hannover, Germany","institution_ids":["https://openalex.org/I114112103"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.6492,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.81551518,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"1","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.7409847378730774},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.7346233129501343},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.6400384306907654},{"id":"https://openalex.org/keywords/transient-recovery-voltage","display_name":"Transient recovery voltage","score":0.6351115107536316},{"id":"https://openalex.org/keywords/thyristor","display_name":"Thyristor","score":0.610447347164154},{"id":"https://openalex.org/keywords/emtp","display_name":"Emtp","score":0.5925639271736145},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.5827064514160156},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5733669996261597},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5598968863487244},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5486994981765747},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4984719753265381},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4466448426246643},{"id":"https://openalex.org/keywords/transient-voltage-suppressor","display_name":"Transient voltage suppressor","score":0.4227978587150574},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4037987291812897},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3994384706020355},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.3390779197216034},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.29355260729789734},{"id":"https://openalex.org/keywords/constant-power-circuit","display_name":"Constant power circuit","score":0.23599809408187866}],"concepts":[{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.7409847378730774},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.7346233129501343},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6400384306907654},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.6351115107536316},{"id":"https://openalex.org/C121922863","wikidata":"https://www.wikidata.org/wiki/Q180805","display_name":"Thyristor","level":3,"score":0.610447347164154},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.5925639271736145},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.5827064514160156},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5733669996261597},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5598968863487244},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5486994981765747},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4984719753265381},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4466448426246643},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.4227978587150574},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4037987291812897},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3994384706020355},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.3390779197216034},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.29355260729789734},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.23599809408187866},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccece.2012.6334818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccece.2012.6334818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 25th IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7599999904632568}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1578978182","https://openalex.org/W2053605468","https://openalex.org/W2081099729","https://openalex.org/W2083174631","https://openalex.org/W2121801816","https://openalex.org/W2154353632","https://openalex.org/W2315596521","https://openalex.org/W2741719352","https://openalex.org/W6663408269","https://openalex.org/W6670785630","https://openalex.org/W6678092735","https://openalex.org/W6699484992","https://openalex.org/W6741985262"],"related_works":["https://openalex.org/W2141520313","https://openalex.org/W4252692404","https://openalex.org/W2181900572","https://openalex.org/W2121862791","https://openalex.org/W2588018340","https://openalex.org/W2125321628","https://openalex.org/W2156023424","https://openalex.org/W2585325717","https://openalex.org/W3102738826","https://openalex.org/W3049530665"],"abstract_inverted_index":{"Future's":[0],"load":[1],"and":[2,14,78,89,110],"generation":[3],"model":[4],"of":[5,16,35,38,44,48,59,106,120,122],"Tehran":[6,72,107],"power":[7,17,73,108],"network":[8,109],"depicts":[9],"fast":[10],"increase":[11,34],"in":[12,32,42,71,103,134],"demand":[13],"development":[15],"network.":[18],"By":[19],"2015,":[20],"Two":[21],"new":[22],"generating":[23],"stations":[24],"are":[25],"expected":[26],"to":[27,55],"be":[28,138],"installed":[29],"which":[30,136],"result":[31],"the":[33,45,57,116,131],"short-circuit":[36,67],"capacity":[37],"a":[39],"few":[40],"substations":[41,105],"excess":[43],"interrupting":[46],"rating":[47],"exiting":[49],"circuit":[50,127],"breakers.":[51],"This":[52],"paper":[53],"intends":[54],"analyze":[56],"consequences":[58],"employing":[60],"thyristor":[61],"protected":[62],"series":[63],"capacitor":[64],"(TPSC)":[65],"based":[66],"current":[68,101],"limiter":[69],"(SCCL)":[70],"grid.":[74],"Short-circuit,":[75],"transient":[76,79,112],"stability":[77,113],"recovery":[80,123],"voltage":[81,124],"studies":[82],"were":[83],"carried":[84],"out":[85],"by":[86,141],"using":[87],"DIgSILENT":[88],"EMTP":[90],"softwares.":[91],"The":[92],"results":[93],"demonstrate":[94],"that":[95],"SCCL":[96],"installation":[97],"can":[98,137],"reduce":[99],"fault":[100],"level":[102],"four":[104],"improve":[111],"margins.":[114],"On":[115],"other":[117],"hand,":[118],"rate":[119],"rise":[121],"across":[125],"some":[126],"breakers":[128],"will":[129],"exceed":[130],"value":[132],"specified":[133],"standard":[135],"coped":[139],"with":[140],"adding":[142],"extra":[143],"capacitor.":[144]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
