{"id":"https://openalex.org/W2166559209","doi":"https://doi.org/10.1109/cca.2009.5281004","title":"Automatic sensor assignment of a supermarket refrigeration system","display_name":"Automatic sensor assignment of a supermarket refrigeration system","publication_year":2009,"publication_date":"2009-07-01","ids":{"openalex":"https://openalex.org/W2166559209","doi":"https://doi.org/10.1109/cca.2009.5281004","mag":"2166559209"},"language":"en","primary_location":{"id":"doi:10.1109/cca.2009.5281004","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2009.5281004","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE Control Applications, (CCA) &amp; Intelligent Control, (ISIC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/da/publications/cb4b9cd0-4ede-11de-8bb0-000ea68e967b","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108220058","display_name":"S.M. Tabatabaeipour","orcid":null},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":true,"raw_author_name":"Seyedmojtaba Tabatabaeipour","raw_affiliation_strings":["Department of Electronic Systems, Aalborg University, DK-9220, Denmark","Department of Electronic Systems, University of Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Systems, Aalborg University, DK-9220, Denmark","institution_ids":["https://openalex.org/I891191580"]},{"raw_affiliation_string":"Department of Electronic Systems, University of Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088730202","display_name":"Roozbeh Izadi\u2010Zamanabadi","orcid":"https://orcid.org/0000-0002-5889-0988"},"institutions":[{"id":"https://openalex.org/I4210117054","display_name":"Danfoss (Denmark)","ror":"https://ror.org/039pgdx28","country_code":"DK","type":"company","lineage":["https://openalex.org/I4210117054"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Roozbeh Izadi-zamabadi","raw_affiliation_strings":["Central R&D-RA-DP, Danfoss A/S, DK-6470, Denmark","Central Research and Development-RA-DP, Danfoss Drives AS, Denmark"],"affiliations":[{"raw_affiliation_string":"Central R&D-RA-DP, Danfoss A/S, DK-6470, Denmark","institution_ids":["https://openalex.org/I4210117054"]},{"raw_affiliation_string":"Central Research and Development-RA-DP, Danfoss Drives AS, Denmark","institution_ids":["https://openalex.org/I4210117054"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000342673","display_name":"Thomas Bak","orcid":"https://orcid.org/0000-0002-8282-5932"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Thomas Bak","raw_affiliation_strings":["Department of Electronic Systems, Aalborg University, DK-9220, Denmark","Department of Electronic Systems, University of Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Systems, Aalborg University, DK-9220, Denmark","institution_ids":["https://openalex.org/I891191580"]},{"raw_affiliation_string":"Department of Electronic Systems, University of Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5033777370","display_name":"Anders P. Ravn","orcid":null},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Anders P. Ravn","raw_affiliation_strings":["Department of Computer Science, Aalborg University, DK-9220, Denmark","Department of Computer Science, University of Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Computer Science, Aalborg University, DK-9220, Denmark","institution_ids":["https://openalex.org/I891191580"]},{"raw_affiliation_string":"Department of Computer Science, University of Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5108220058"],"corresponding_institution_ids":["https://openalex.org/I891191580"],"apc_list":null,"apc_paid":null,"fwci":1.5397,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.87015407,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1319","last_page":"1324"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9876999855041504,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5565229058265686},{"id":"https://openalex.org/keywords/refrigeration","display_name":"Refrigeration","score":0.5473780632019043},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.49243244528770447},{"id":"https://openalex.org/keywords/project-commissioning","display_name":"Project commissioning","score":0.446774959564209},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.43737146258354187},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.41893184185028076},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.39583826065063477},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.2834320366382599}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5565229058265686},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.5473780632019043},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.49243244528770447},{"id":"https://openalex.org/C165347436","wikidata":"https://www.wikidata.org/wiki/Q1514547","display_name":"Project commissioning","level":3,"score":0.446774959564209},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.43737146258354187},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.41893184185028076},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39583826065063477},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2834320366382599},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C151719136","wikidata":"https://www.wikidata.org/wiki/Q3972943","display_name":"Publishing","level":2,"score":0.0},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/cca.2009.5281004","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2009.5281004","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE Control Applications, (CCA) &amp; Intelligent Control, (ISIC)","raw_type":"proceedings-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.658.7567","is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.658.7567","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"http://vbn.aau.dk/files/56756437/Automatic_sensor_assignment_of_a_supermarket_refrigeration_system.pdf","raw_type":"text"},{"id":"pmh:oai:pure.atira.dk:openaire/cb4b9cd0-4ede-11de-8bb0-000ea68e967b","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/cb4b9cd0-4ede-11de-8bb0-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Tabatabaeipour, S M, Izadi-Zamanabadi, R, Bak, T & Ravn, A P 2009, 'Automatic sensor assignment of a supermarket refrigeration system', I E E E Conference on Control Applications. Proceedings, pp. 1319\u20131324. https://doi.org/10.1109/CCA.2009.5281004","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:openaire/cb4b9cd0-4ede-11de-8bb0-000ea68e967b","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/cb4b9cd0-4ede-11de-8bb0-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Tabatabaeipour, S M, Izadi-Zamanabadi, R, Bak, T & Ravn, A P 2009, 'Automatic sensor assignment of a supermarket refrigeration system', I E E E Conference on Control Applications. Proceedings, pp. 1319\u20131324. https://doi.org/10.1109/CCA.2009.5281004","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W572601373","https://openalex.org/W1485129834","https://openalex.org/W1532859487","https://openalex.org/W1994718294","https://openalex.org/W2037802202","https://openalex.org/W2096407588","https://openalex.org/W2109559642","https://openalex.org/W2120804790","https://openalex.org/W2126410464","https://openalex.org/W2127318632","https://openalex.org/W2129039806","https://openalex.org/W6649077116"],"related_works":["https://openalex.org/W2565024283","https://openalex.org/W1603037600","https://openalex.org/W2105377682","https://openalex.org/W2024029001","https://openalex.org/W3198062226","https://openalex.org/W2506961986","https://openalex.org/W854832400","https://openalex.org/W1914125489","https://openalex.org/W2085789123","https://openalex.org/W2089909366"],"abstract_inverted_index":{"Wrong":[0],"sensor":[1,23],"assignment":[2,24],"is":[3,29,35,98],"a":[4,19,101],"major":[5],"source":[6],"of":[7,39,68,74,79,90,93],"faults":[8,69,80],"in":[9],"industrial":[10],"systems":[11],"during":[12,70],"the":[13,45,57,71,94],"commissioning":[14,58],"phase.":[15,59],"In":[16],"this":[17],"paper":[18],"method":[20,34,97],"for":[21,37,53,65,77],"automatic":[22],"based":[25],"on":[26,100],"active":[27,32],"diagnosis":[28,33,38],"proposed.":[30],"The":[31,96],"developed":[36],"linear":[40],"hybrid":[41],"systems.":[42],"It":[43,60],"generates":[44],"appropriate":[46],"test":[47],"signal":[48],"which":[49,81],"can":[50],"be":[51,63],"used":[52,64],"sanity":[54],"check":[55],"at":[56],"could":[61],"also":[62],"faster":[66],"detection":[67,78],"normal":[72],"phase":[73],"operation":[75],"or":[76],"are":[82],"impossible":[83],"to":[84],"detect":[85],"by":[86],"passive":[87],"methods":[88],"because":[89],"regulatory":[91],"actions":[92],"controller.":[95],"tested":[99],"supermarket":[102],"refrigeration":[103],"system.":[104]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-03-25T13:04:00.132906","created_date":"2025-10-10T00:00:00"}