{"id":"https://openalex.org/W1513596662","doi":"https://doi.org/10.1109/cca.2004.1387541","title":"Model based fault diagnosis in a centrifugal pump application using structural analysis","display_name":"Model based fault diagnosis in a centrifugal pump application using structural analysis","publication_year":2005,"publication_date":"2005-03-07","ids":{"openalex":"https://openalex.org/W1513596662","doi":"https://doi.org/10.1109/cca.2004.1387541","mag":"1513596662"},"language":"en","primary_location":{"id":"doi:10.1109/cca.2004.1387541","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2004.1387541","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2004 IEEE International Conference on Control Applications, 2004.","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/da/publications/318a2500-9c2d-11db-8ed6-000ea68e967b","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5045171559","display_name":"Carsten Skovmose Kalles\u00f8e","orcid":"https://orcid.org/0000-0002-4197-6777"},"institutions":[{"id":"https://openalex.org/I4210161280","display_name":"Grundfos (Denmark)","ror":"https://ror.org/05rdv5n40","country_code":"DK","type":"company","lineage":["https://openalex.org/I4210161280","https://openalex.org/I4392738325"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"C.S. Kallesoe","raw_affiliation_strings":["Grundfos Management A/S Poul, Bjerringbro, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grundfos Management A/S Poul, Bjerringbro, Denmark","institution_ids":["https://openalex.org/I4210161280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107825556","display_name":"R. Izaili-Zamanabadi","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R. Izaili-Zamanabadi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081883606","display_name":"Hanne N. Rasmussen","orcid":"https://orcid.org/0000-0002-0181-9304"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"H. Rasmussen","raw_affiliation_strings":["Dept. of Control Engineering, Aalborg University, Aalborg \u00d8, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Control Engineering, Aalborg University, Aalborg \u00d8, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5029541965","display_name":"Vincent Cocquempot","orcid":"https://orcid.org/0000-0001-7281-911X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"V. Cocquempot","raw_affiliation_strings":["USTL - LAIL, France","USTL - LAIL, Villeneuve d'Ascq, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"USTL - LAIL, France","institution_ids":[]},{"raw_affiliation_string":"USTL - LAIL, Villeneuve d'Ascq, France","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6191,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.58389783,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"2","issue":null,"first_page":"1229","last_page":"1235"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9825999736785889,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.8425745964050293},{"id":"https://openalex.org/keywords/benchmark","display_name":"Benchmark (surveying)","score":0.8038853406906128},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.6862567067146301},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.5959307551383972},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5448635816574097},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5299720764160156},{"id":"https://openalex.org/keywords/centrifugal-pump","display_name":"Centrifugal pump","score":0.5257283449172974},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.5119258165359497},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.4213916063308716},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.36600443720817566},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3309018015861511},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.15646544098854065},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.1171034574508667},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.061362624168395996}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.8425745964050293},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.8038853406906128},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.6862567067146301},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.5959307551383972},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5448635816574097},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5299720764160156},{"id":"https://openalex.org/C166675230","wikidata":"https://www.wikidata.org/wiki/Q627111","display_name":"Centrifugal pump","level":3,"score":0.5257283449172974},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.5119258165359497},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.4213916063308716},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.36600443720817566},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3309018015861511},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.15646544098854065},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.1171034574508667},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.061362624168395996},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C153005164","wikidata":"https://www.wikidata.org/wiki/Q1698700","display_name":"Impeller","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/cca.2004.1387541","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2004.1387541","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2004 IEEE International Conference on Control Applications, 2004.","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:publications/318a2500-9c2d-11db-8ed6-000ea68e967b","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/318a2500-9c2d-11db-8ed6-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Kalles\u00f8e, C S, Izadi-Zamanabadi, R, Rasmussen, H & Cocquempot, V 2004 'Model Based Fault Diagnosis in a Centrifugal Pump Application using Structural Analysis'.","raw_type":"workingPaper"},{"id":"pmh:oai:pure.atira.dk:publications/e4e8e050-9c2d-11db-8ed6-000ea68e967b","is_oa":false,"landing_page_url":"https://vbn.aau.dk/da/publications/e4e8e050-9c2d-11db-8ed6-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Kalles\u00f8e, C S, Izadi-Zamanabadi, R, Rasmussen, H & Cocquempot, V 2004, Model based fault diagnosis in a centrifugal pump application using structural analysis. i Proceedings of IEEE Conference on Control Applications, CCA2004, Taiwan. Model based fault diagnosis in a centrifugal pump application using structural analysis, 19/05/2010.","raw_type":"contributionToPeriodical"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/318a2500-9c2d-11db-8ed6-000ea68e967b","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/318a2500-9c2d-11db-8ed6-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Kalles\u00f8e, C S, Izadi-Zamanabadi, R, Rasmussen, H & Cocquempot, V 2004 'Model Based Fault Diagnosis in a Centrifugal Pump Application using Structural Analysis'.","raw_type":"workingPaper"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W95498564","https://openalex.org/W300721812","https://openalex.org/W1482540049","https://openalex.org/W1507884046","https://openalex.org/W1510598017","https://openalex.org/W1579424694","https://openalex.org/W1756164819","https://openalex.org/W1994646886","https://openalex.org/W2325067522","https://openalex.org/W2328076313","https://openalex.org/W2543844616","https://openalex.org/W4240466925","https://openalex.org/W6637902034"],"related_works":["https://openalex.org/W2560215812","https://openalex.org/W4366779835","https://openalex.org/W2005356353","https://openalex.org/W4385301753","https://openalex.org/W3186428265","https://openalex.org/W2171501125","https://openalex.org/W2617234683","https://openalex.org/W3121254296","https://openalex.org/W2060193301","https://openalex.org/W2375947351"],"abstract_inverted_index":{"A":[0],"model":[1],"based":[2],"approach":[3],"for":[4,67,80],"fault":[5,19,81],"detection":[6,20,108],"and":[7,34,109,118],"isolation":[8,110],"in":[9,15,115],"a":[10,25,51,62],"centrifugal":[11],"pump":[12],"is":[13,22,65,88,105],"proposed":[14],"this":[16],"paper.":[17],"The":[18,73,83,97],"algorithm":[21,87,104],"derived":[23],"using":[24],"combination":[26],"of":[27,53,69,85,107,111,121],"structural":[28],"analysis,":[29],"analytical":[30],"redundant":[31],"relations":[32],"(ARR)":[33],"observer":[35,64],"designs.":[36],"Structural":[37],"considerations":[38],"on":[39],"the":[40,54,70,86,103,116,122],"system":[41],"are":[42,77],"used":[43,79],"to":[44,50,93],"identify":[45],"four":[46,71,74],"subsystems":[47],"each":[48,68],"sensitive":[49],"subset":[52],"faults":[55,114],"under":[56],"consideration.":[57],"Either":[58],"an":[59,94],"ARR":[60],"or":[61],"residual":[63],"designed":[66],"subsystems.":[72],"obtained":[75],"residuals":[76],"then":[78],"isolation.":[82],"applicability":[84],"illustrated":[89],"by":[90],"applying":[91],"it":[92],"industrial":[95],"benchmark.":[96],"benchmark":[98],"tests":[99],"have":[100],"shown":[101],"that":[102],"capable":[106],"five":[112],"different":[113],"mechanical":[117],"hydraulic":[119],"parts":[120],"pump.":[123]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
