{"id":"https://openalex.org/W3092594337","doi":"https://doi.org/10.1109/case48305.2020.9216880","title":"A Building Energy Management System for demand response in smart grids","display_name":"A Building Energy Management System for demand response in smart grids","publication_year":2020,"publication_date":"2020-08-01","ids":{"openalex":"https://openalex.org/W3092594337","doi":"https://doi.org/10.1109/case48305.2020.9216880","mag":"3092594337"},"language":"en","primary_location":{"id":"doi:10.1109/case48305.2020.9216880","is_oa":false,"landing_page_url":"https://doi.org/10.1109/case48305.2020.9216880","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 16th International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059547739","display_name":"Giovanni Bianco","orcid":"https://orcid.org/0000-0002-3299-4885"},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"G. Bianco","raw_affiliation_strings":["Department of Informatics, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Informatics, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026808011","display_name":"Stefano Bracco","orcid":"https://orcid.org/0000-0002-6021-0291"},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"S. Bracco","raw_affiliation_strings":["Department of Informatics, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Informatics, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033851703","display_name":"Federico Delfino","orcid":"https://orcid.org/0000-0003-2876-2667"},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"F. Delfino","raw_affiliation_strings":["Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078169668","display_name":"Lorenzo Gambelli","orcid":null},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"L. Gambelli","raw_affiliation_strings":["Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039477899","display_name":"Michela Robba","orcid":"https://orcid.org/0000-0002-0032-9493"},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"M. Robba","raw_affiliation_strings":["Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043448211","display_name":"Mansueto Rossi","orcid":"https://orcid.org/0000-0001-6137-9454"},"institutions":[{"id":"https://openalex.org/I83816512","display_name":"University of Genoa","ror":"https://ror.org/0107c5v14","country_code":"IT","type":"education","lineage":["https://openalex.org/I83816512"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"M. Rossi","raw_affiliation_strings":["Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Naval, Electrical, and Telecommunication Engineering, University of Genoa, Italy","institution_ids":["https://openalex.org/I83816512"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I83816512"],"apc_list":null,"apc_paid":null,"fwci":0.5203,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.65656271,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1485","last_page":"1490"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.972000002861023,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9233842492103577},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.821967601776123},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.6886008977890015},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5956333875656128},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.5923159122467041},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.5457261800765991},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.49165278673171997},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.4904474914073944},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4847790598869324},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.4628213346004486},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.4619795083999634},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45754215121269226},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4503431022167206},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.4400070011615753},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.435062438249588},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.3919408321380615},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.368447870016098},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.30743861198425293},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16058847308158875},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.15177592635154724}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9233842492103577},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.821967601776123},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.6886008977890015},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5956333875656128},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5923159122467041},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.5457261800765991},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.49165278673171997},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4904474914073944},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4847790598869324},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.4628213346004486},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4619795083999634},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45754215121269226},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4503431022167206},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.4400070011615753},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.435062438249588},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.3919408321380615},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.368447870016098},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.30743861198425293},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16058847308158875},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.15177592635154724},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/case48305.2020.9216880","is_oa":false,"landing_page_url":"https://doi.org/10.1109/case48305.2020.9216880","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 16th International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.unige.it:11567/1066850","is_oa":false,"landing_page_url":"https://hdl.handle.net/11567/1066850","pdf_url":null,"source":{"id":"https://openalex.org/S4377196291","display_name":"CINECA IRIS Institutial Research Information System (University of Genoa)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I83816512","host_organization_name":"University of Genoa","host_organization_lineage":["https://openalex.org/I83816512"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1972802966","https://openalex.org/W1983563831","https://openalex.org/W2093447280","https://openalex.org/W2136282315","https://openalex.org/W2560235419","https://openalex.org/W2605614336","https://openalex.org/W2789880759","https://openalex.org/W2801231754","https://openalex.org/W2895612645","https://openalex.org/W2905558533","https://openalex.org/W2907524694","https://openalex.org/W2921150354","https://openalex.org/W2941870083","https://openalex.org/W2972412491","https://openalex.org/W2996723446"],"related_works":["https://openalex.org/W2749654269","https://openalex.org/W4240359851","https://openalex.org/W2538009942","https://openalex.org/W4286354644","https://openalex.org/W4255224640","https://openalex.org/W4200325458","https://openalex.org/W3031841740","https://openalex.org/W2296534813","https://openalex.org/W2735458449","https://openalex.org/W2329485921"],"abstract_inverted_index":{"A":[0],"BEMS":[1,35],"(Building":[2],"Energy":[3,84],"Management":[4],"System)":[5],"for":[6,11,76],"demand":[7,64],"response":[8,65],"is":[9,36],"proposed":[10],"a":[12,19,29,68,77],"smart":[13],"building":[14],"equipped":[15],"with":[16],"renewables":[17],"and":[18,22,50,62],"Heating,":[20],"Ventilation":[21],"Air":[23],"Conditioning":[24],"System":[25,71],"(HVAC)":[26],"fed":[27],"by":[28,81],"geothermal":[30],"heat":[31],"pump.":[32],"The":[33],"developed":[34],"based":[37],"on":[38],"an":[39],"optimization":[40],"model":[41],"able":[42],"to":[43,53],"manage":[44],"the":[45,57,82],"HVAC":[46],"plant,":[47],"fan":[48],"coils":[49],"rooms'":[51],"temperature":[52],"minimize":[54],"costs,":[55],"guarantee":[56],"desired":[58],"comfort":[59],"inside":[60],"rooms,":[61],"track":[63],"signals":[66],"from":[67],"DSO":[69],"(Distribution":[70],"Operator).":[72],"Results":[73],"are":[74],"provided":[75],"real":[78],"test-case":[79],"represented":[80],"Smart":[83],"Building":[85],"(SEB)":[86],"located":[87],"at":[88],"Savona":[89],"Campus":[90],"(University":[91],"of":[92],"Genoa,":[93],"Italy).":[94]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
