{"id":"https://openalex.org/W2047154494","doi":"https://doi.org/10.1109/case.2011.6042530","title":"Use of Ethernet communications for real-time control systems in the metals industry","display_name":"Use of Ethernet communications for real-time control systems in the metals industry","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W2047154494","doi":"https://doi.org/10.1109/case.2011.6042530","mag":"2047154494"},"language":"en","primary_location":{"id":"doi:10.1109/case.2011.6042530","is_oa":false,"landing_page_url":"https://doi.org/10.1109/case.2011.6042530","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Conference on Automation Science and Engineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048609764","display_name":"Lanfranco Urli","orcid":null},"institutions":[{"id":"https://openalex.org/I2801958098","display_name":"Ansaldo (Italy)","ror":"https://ror.org/03ynt1573","country_code":"IT","type":"company","lineage":["https://openalex.org/I2801958098"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Lanfranco Urli","raw_affiliation_strings":["Ansaldo Sistemi Industriali S.p.A., Genova, Italy","Ansaldo Sistemi Industriali S.p.A:, Genoa, 16157, ITALY"],"affiliations":[{"raw_affiliation_string":"Ansaldo Sistemi Industriali S.p.A., Genova, Italy","institution_ids":["https://openalex.org/I2801958098"]},{"raw_affiliation_string":"Ansaldo Sistemi Industriali S.p.A:, Genoa, 16157, ITALY","institution_ids":["https://openalex.org/I2801958098"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014395519","display_name":"Sergio Murgia","orcid":null},"institutions":[{"id":"https://openalex.org/I2801958098","display_name":"Ansaldo (Italy)","ror":"https://ror.org/03ynt1573","country_code":"IT","type":"company","lineage":["https://openalex.org/I2801958098"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Sergio Murgia","raw_affiliation_strings":["Ansaldo Sistemi Industriali S.p.A., Genova, Italy","Ansaldo Sistemi Industriali S.p.A:, Genoa, 16157, ITALY"],"affiliations":[{"raw_affiliation_string":"Ansaldo Sistemi Industriali S.p.A., Genova, Italy","institution_ids":["https://openalex.org/I2801958098"]},{"raw_affiliation_string":"Ansaldo Sistemi Industriali S.p.A:, Genoa, 16157, ITALY","institution_ids":["https://openalex.org/I2801958098"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5048609764"],"corresponding_institution_ids":["https://openalex.org/I2801958098"],"apc_list":null,"apc_paid":null,"fwci":0.7002,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.71862872,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"6","last_page":"11"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9283999800682068,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9283999800682068,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.9025999903678894,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ethernet","display_name":"Ethernet","score":0.6301840543746948},{"id":"https://openalex.org/keywords/carrier-ethernet","display_name":"Carrier Ethernet","score":0.6109819412231445},{"id":"https://openalex.org/keywords/industrial-ethernet","display_name":"Industrial Ethernet","score":0.5656713247299194},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5304327011108398},{"id":"https://openalex.org/keywords/connection-oriented-ethernet","display_name":"Connection-oriented Ethernet","score":0.5093978047370911},{"id":"https://openalex.org/keywords/ethernet-over-pdh","display_name":"Ethernet over PDH","score":0.49735692143440247},{"id":"https://openalex.org/keywords/ethernet-over-sdh","display_name":"Ethernet over SDH","score":0.4824674427509308},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4462505578994751},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.41638731956481934},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4068200886249542},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.3943558633327484},{"id":"https://openalex.org/keywords/ethernet-flow-control","display_name":"Ethernet flow control","score":0.3248355984687805},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22013592720031738},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.0899806022644043}],"concepts":[{"id":"https://openalex.org/C172173386","wikidata":"https://www.wikidata.org/wiki/Q79984","display_name":"Ethernet","level":2,"score":0.6301840543746948},{"id":"https://openalex.org/C151898751","wikidata":"https://www.wikidata.org/wiki/Q5046350","display_name":"Carrier Ethernet","level":3,"score":0.6109819412231445},{"id":"https://openalex.org/C167151114","wikidata":"https://www.wikidata.org/wiki/Q1661930","display_name":"Industrial Ethernet","level":3,"score":0.5656713247299194},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5304327011108398},{"id":"https://openalex.org/C186844356","wikidata":"https://www.wikidata.org/wiki/Q5161679","display_name":"Connection-oriented Ethernet","level":4,"score":0.5093978047370911},{"id":"https://openalex.org/C195801177","wikidata":"https://www.wikidata.org/wiki/Q5403360","display_name":"Ethernet over PDH","level":5,"score":0.49735692143440247},{"id":"https://openalex.org/C30188135","wikidata":"https://www.wikidata.org/wiki/Q1118613","display_name":"Ethernet over SDH","level":4,"score":0.4824674427509308},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4462505578994751},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.41638731956481934},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4068200886249542},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3943558633327484},{"id":"https://openalex.org/C68178114","wikidata":"https://www.wikidata.org/wiki/Q5403359","display_name":"Ethernet flow control","level":3,"score":0.3248355984687805},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22013592720031738},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0899806022644043},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/case.2011.6042530","is_oa":false,"landing_page_url":"https://doi.org/10.1109/case.2011.6042530","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Conference on Automation Science and Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.6299999952316284}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2383348237","https://openalex.org/W2489554667","https://openalex.org/W2525190005","https://openalex.org/W2375023940","https://openalex.org/W2356598257","https://openalex.org/W2113072949","https://openalex.org/W4308088904","https://openalex.org/W2155122972","https://openalex.org/W2375810997","https://openalex.org/W2357111730"],"abstract_inverted_index":{"This":[0,70],"paper":[1,93],"introduces":[2],"and":[3,12,18,53,60,81],"completes":[4],"the":[5,9,20,34,61,64,78,83,97,110],"material":[6],"presented":[7],"in":[8,75],"tutorial":[10],"\u201cAutomation":[11],"real-time":[13,38,105],"simulation":[14],"of":[15,22,36,77,85,91,99],"steelmaking":[16],"processes\u201d":[17],"discusses":[19],"use":[21],"industrial":[23],"protocols,":[24],"based":[25,39,56,106],"on":[26,57],"IEEE":[27],"802.3":[28],"standard":[29,59],"for":[30,51,109],"data":[31],"exchange":[32],"between":[33,63],"layers":[35],"a":[37,104],"automation":[40,43,107],"system.":[41],"Modern":[42],"platform":[44,108],"needs":[45],"to":[46,95,103],"replace":[47],"legacy":[48],"field":[49],"bus,":[50],"drive":[52],"remote":[54],"I/O,":[55],"RS485":[58],"communication":[62],"control":[65,79],"systems,":[66],"with":[67],"Ethernet":[68,101],"management.":[69],"improvement":[71],"allows":[72],"an":[73],"increase":[74],"performance":[76],"system":[80],"makes":[82],"recovery":[84],"diagnostic":[86],"information":[87],"easier.":[88],"The":[89],"aim":[90],"this":[92],"is":[94],"illustrate":[96],"application":[98],"modern":[100],"communications":[102],"metals":[111],"industry.":[112]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
