{"id":"https://openalex.org/W3192536264","doi":"https://doi.org/10.1109/cacre52464.2021.9501363","title":"Predictive Current Control of Switched Reluctance Motor Based on Extended Observer","display_name":"Predictive Current Control of Switched Reluctance Motor Based on Extended Observer","publication_year":2021,"publication_date":"2021-07-01","ids":{"openalex":"https://openalex.org/W3192536264","doi":"https://doi.org/10.1109/cacre52464.2021.9501363","mag":"3192536264"},"language":"en","primary_location":{"id":"doi:10.1109/cacre52464.2021.9501363","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cacre52464.2021.9501363","pdf_url":null,"source":{"id":"https://openalex.org/S4306498778","display_name":"2021 6th International Conference on Automation, Control and Robotics Engineering (CACRE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 6th International Conference on Automation, Control and Robotics Engineering (CACRE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010611037","display_name":"Yunsheng Fan","orcid":"https://orcid.org/0000-0001-7828-4902"},"institutions":[{"id":"https://openalex.org/I43313876","display_name":"Dalian Maritime University","ror":"https://ror.org/002b7nr53","country_code":"CN","type":"education","lineage":["https://openalex.org/I43313876"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Fan Yunsheng","raw_affiliation_strings":["College of Marine Electrical Engineering Dalian Maritime University, Dalian, China"],"affiliations":[{"raw_affiliation_string":"College of Marine Electrical Engineering Dalian Maritime University, Dalian, China","institution_ids":["https://openalex.org/I43313876"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100651407","display_name":"Yue Liu","orcid":"https://orcid.org/0000-0002-6929-0080"},"institutions":[{"id":"https://openalex.org/I43313876","display_name":"Dalian Maritime University","ror":"https://ror.org/002b7nr53","country_code":"CN","type":"education","lineage":["https://openalex.org/I43313876"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liu Yue","raw_affiliation_strings":["College of Marine Electrical Engineering Dalian Maritime University, Dalian, China"],"affiliations":[{"raw_affiliation_string":"College of Marine Electrical Engineering Dalian Maritime University, Dalian, China","institution_ids":["https://openalex.org/I43313876"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102005817","display_name":"Di Liu","orcid":"https://orcid.org/0000-0001-7891-7853"},"institutions":[{"id":"https://openalex.org/I43313876","display_name":"Dalian Maritime University","ror":"https://ror.org/002b7nr53","country_code":"CN","type":"education","lineage":["https://openalex.org/I43313876"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liu Di","raw_affiliation_strings":["College of Marine Electrical Engineering Dalian Maritime University, Dalian, China"],"affiliations":[{"raw_affiliation_string":"College of Marine Electrical Engineering Dalian Maritime University, Dalian, China","institution_ids":["https://openalex.org/I43313876"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5010611037"],"corresponding_institution_ids":["https://openalex.org/I43313876"],"apc_list":null,"apc_paid":null,"fwci":1.2982,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.74000972,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"150","last_page":"156"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9922000169754028,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9864000082015991,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8710739016532898},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.6810117959976196},{"id":"https://openalex.org/keywords/switched-reluctance-motor","display_name":"Switched reluctance motor","score":0.6809028387069702},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.6707881689071655},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.623516321182251},{"id":"https://openalex.org/keywords/current-loop","display_name":"Current loop","score":0.5566831827163696},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.5246567726135254},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.509231448173523},{"id":"https://openalex.org/keywords/state-observer","display_name":"State observer","score":0.5060006976127625},{"id":"https://openalex.org/keywords/ripple","display_name":"Ripple","score":0.47505685687065125},{"id":"https://openalex.org/keywords/jitter","display_name":"Jitter","score":0.469535231590271},{"id":"https://openalex.org/keywords/torque-ripple","display_name":"Torque ripple","score":0.4615372121334076},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4188452363014221},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.30290496349334717},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.30114686489105225},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2980723977088928},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.15941119194030762},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07683825492858887}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8710739016532898},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.6810117959976196},{"id":"https://openalex.org/C12090584","wikidata":"https://www.wikidata.org/wiki/Q4107232","display_name":"Switched reluctance motor","level":3,"score":0.6809028387069702},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.6707881689071655},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.623516321182251},{"id":"https://openalex.org/C123414225","wikidata":"https://www.wikidata.org/wiki/Q1422221","display_name":"Current loop","level":3,"score":0.5566831827163696},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.5246567726135254},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.509231448173523},{"id":"https://openalex.org/C3031470","wikidata":"https://www.wikidata.org/wiki/Q818544","display_name":"State observer","level":3,"score":0.5060006976127625},{"id":"https://openalex.org/C2779599953","wikidata":"https://www.wikidata.org/wiki/Q1776117","display_name":"Ripple","level":3,"score":0.47505685687065125},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.469535231590271},{"id":"https://openalex.org/C2779675184","wikidata":"https://www.wikidata.org/wiki/Q7826797","display_name":"Torque ripple","level":5,"score":0.4615372121334076},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4188452363014221},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.30290496349334717},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.30114686489105225},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2980723977088928},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.15941119194030762},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07683825492858887},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cacre52464.2021.9501363","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cacre52464.2021.9501363","pdf_url":null,"source":{"id":"https://openalex.org/S4306498778","display_name":"2021 6th International Conference on Automation, Control and Robotics Engineering (CACRE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 6th International Conference on Automation, Control and Robotics Engineering (CACRE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4099999964237213,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G802126860","display_name":null,"funder_award_id":"51609033","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1545116338","https://openalex.org/W2051689496","https://openalex.org/W2141045440","https://openalex.org/W2157704316","https://openalex.org/W2523409207"],"related_works":["https://openalex.org/W1481613091","https://openalex.org/W2120428238","https://openalex.org/W4362647495","https://openalex.org/W2790336310","https://openalex.org/W3092332108","https://openalex.org/W2294550331","https://openalex.org/W2098405401","https://openalex.org/W2902077064","https://openalex.org/W2123130428","https://openalex.org/W2088292708"],"abstract_inverted_index":{"In":[0,109],"order":[1,110],"to":[2,111,128],"solve":[3],"the":[4,14,18,39,71,77,83,89,92,97,102,107,113,116,130,134,140,146,155,161,166],"problem":[5],"of":[6,91,106,115,133],"current":[7,11,21,26,42,53,69,78,103,137,141,162],"jitter":[8,163],"caused":[9],"by":[10,76,88],"not":[12],"following":[13],"given":[15],"value":[16],"in":[17,70],"traditional":[19,40,135],"deadbeat":[20,41,136],"predictive":[22,27,43,72,142],"control":[23,28,44,73,93,138,143],"system,":[24],"a":[25,62,119],"method":[29],"based":[30,144],"on":[31,38,145],"extended":[32,47,147],"state":[33,48,148],"observer":[34,49],"was":[35,126],"proposed.":[36],"Based":[37],"algorithm,":[45],"an":[46],"mathematical":[50],"model":[51],"including":[52],"and":[54,56,61,81,139,164],"internal":[55],"external":[57],"disturbances":[58],"is":[59,65,74,86],"established,":[60],"weight":[63],"factor":[64],"introduced.":[66],"The":[67,150],"reference":[68,84],"modified":[75],"observation":[79],"value,":[80],"then":[82],"voltage":[85],"compensated":[87],"disturbance":[90,105],"system":[94],"obtained":[95],"from":[96],"observation,":[98],"which":[99],"effectively":[100,159],"reduces":[101],"loop":[104],"system.":[108],"verify":[112],"feasibility":[114],"proposed":[117,156],"scheme,":[118],"three-phase":[120],"12/8":[121],"pole":[122],"switched":[123],"reluctance":[124],"motor":[125],"used":[127],"build":[129],"simulation":[131,151],"models":[132],"observer.":[149],"results":[152],"show":[153],"that":[154],"scheme":[157],"can":[158],"reduce":[160],"restrain":[165],"torque":[167],"ripple.":[168]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-25T21:42:39.735039","created_date":"2025-10-10T00:00:00"}
