{"id":"https://openalex.org/W2795456268","doi":"https://doi.org/10.1109/bsn.2018.8329661","title":"An ergonomic wearable core body temperature sensor","display_name":"An ergonomic wearable core body temperature sensor","publication_year":2018,"publication_date":"2018-03-01","ids":{"openalex":"https://openalex.org/W2795456268","doi":"https://doi.org/10.1109/bsn.2018.8329661","mag":"2795456268"},"language":"en","primary_location":{"id":"doi:10.1109/bsn.2018.8329661","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bsn.2018.8329661","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072769879","display_name":"Louis Atallah","orcid":"https://orcid.org/0000-0002-6657-319X"},"institutions":[{"id":"https://openalex.org/I4210131230","display_name":"Philips (United States)","ror":"https://ror.org/03kw6wr76","country_code":"US","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210131230"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Louis Atallah","raw_affiliation_strings":["Acute Care Solutions Department, Philips Research North America, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Acute Care Solutions Department, Philips Research North America, Cambridge, MA, USA","institution_ids":["https://openalex.org/I4210131230"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023442684","display_name":"Calina Ciuhu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Calina Ciuhu","raw_affiliation_strings":["Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Chao Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Chao Wang","raw_affiliation_strings":["Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042621991","display_name":"Edwin Bongers","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Edwin Bongers","raw_affiliation_strings":["Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022491776","display_name":"Toon Blom","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Toon Blom","raw_affiliation_strings":["Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064591505","display_name":"Igor Paulussen","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Igor Paulussen","raw_affiliation_strings":["Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Patient Care Solutions Department, Philips Research, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109278787","display_name":"Gerrit-Jan Noordergraaf","orcid":null},"institutions":[{"id":"https://openalex.org/I4210149554","display_name":"Elisabeth-TweeSteden Ziekenhuis","ror":"https://ror.org/04gpfvy81","country_code":"NL","type":"healthcare","lineage":["https://openalex.org/I4210149554"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Gerrit-Jan Noordergraaf","raw_affiliation_strings":["Department of Anesthesiology at St Elisabeth Ziekenhuis/Traumacentrum, Tilburg, GC, Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Anesthesiology at St Elisabeth Ziekenhuis/Traumacentrum, Tilburg, GC, Netherlands","institution_ids":["https://openalex.org/I4210149554"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0275,"has_fulltext":false,"cited_by_count":19,"citation_normalized_percentile":{"value":0.86568275,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"70","last_page":"73"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11861","display_name":"Thermal Regulation in Medicine","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11861","display_name":"Thermal Regulation in Medicine","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12994","display_name":"Infrared Thermography in Medicine","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11109","display_name":"Thermoregulation and physiological responses","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.668911337852478},{"id":"https://openalex.org/keywords/forehead","display_name":"Forehead","score":0.6129236817359924},{"id":"https://openalex.org/keywords/core","display_name":"Core (optical fiber)","score":0.5492411255836487},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.4754233658313751},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42500314116477966},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.368749737739563},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.2169424593448639},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.2032773792743683},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.18235543370246887},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.1397138237953186},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12462005019187927}],"concepts":[{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.668911337852478},{"id":"https://openalex.org/C2780446394","wikidata":"https://www.wikidata.org/wiki/Q41055","display_name":"Forehead","level":2,"score":0.6129236817359924},{"id":"https://openalex.org/C2164484","wikidata":"https://www.wikidata.org/wiki/Q5170150","display_name":"Core (optical fiber)","level":2,"score":0.5492411255836487},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.4754233658313751},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42500314116477966},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.368749737739563},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2169424593448639},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.2032773792743683},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.18235543370246887},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1397138237953186},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12462005019187927},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bsn.2018.8329661","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bsn.2018.8329661","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W2010277406","https://openalex.org/W2025601974","https://openalex.org/W2046726856","https://openalex.org/W2063398203","https://openalex.org/W2063651680","https://openalex.org/W2084086178","https://openalex.org/W2175642127","https://openalex.org/W2586366032"],"related_works":["https://openalex.org/W2957662356","https://openalex.org/W2055649454","https://openalex.org/W2419783658","https://openalex.org/W2310795625","https://openalex.org/W2424374221","https://openalex.org/W4390429553","https://openalex.org/W3038235736","https://openalex.org/W4383342093","https://openalex.org/W2596898086","https://openalex.org/W2379286237"],"abstract_inverted_index":{"The":[0,106,159],"observation":[1],"of":[2,26,113,120,130,141],"core":[3,27,152,177],"body":[4,28,153,178],"temperature":[5,154,179],"is":[6],"important":[7],"for":[8,123,133,150,156],"several":[9],"hospital":[10,168],"and":[11,58,89,116,126,170],"home":[12],"patients,":[13],"especially":[14],"those":[15],"who":[16,81],"have":[17,32],"undergone":[18],"surgical":[19],"interventions.":[20],"To":[21],"provide":[22],"a":[23,51,66,117,127,138,167],"continuous":[24,151],"estimate":[25],"temperature,":[29],"previous":[30],"approaches":[31],"focused":[33],"on":[34,60,78,84],"embedding":[35],"sensors":[36],"or":[37,44,184],"designing":[38],"forehead":[39,88,125],"patches":[40],"that":[41],"use":[42],"single":[43],"dual":[45],"heat":[46],"flows.":[47],"This":[48,144],"work":[49],"proposes":[50],"foam-based":[52],"Y-shaped":[53],"sensor":[54,77,98,107,146,165],"with":[55,137,173],"flexible":[56],"electronics":[57],"focuses":[59],"the":[61,71,76,87,124,134,148,164],"ergonomic":[62,145],"aspect.":[63],"We":[64],"developed":[65],"laboratory":[67],"setup":[68],"to":[69,175],"derive":[70],"heat-flow":[72],"parameters":[73],"then":[74],"tested":[75],"10":[79],"volunteers":[80],"wore":[82],"it":[83,172],"two":[85],"locations:":[86],"behind":[90],"their":[91],"ear":[92],"(mastoid":[93],"area).":[94],"An":[95],"existing":[96],"zero-heat-flux":[97],"(SpotOn":[99],"by":[100],"3M)":[101],"was":[102],"used":[103],"as":[104,182],"reference.":[105],"had":[108],"an":[109],"average":[110],"heat-up":[111,128],"time":[112,129],"7.7":[114],"minutes":[115,132],"mean":[118,139],"error":[119,140],"0.10":[121],"\u00b0C":[122],"6.9":[131],"mastoid":[135],"area":[136],"0.03":[142],"\u00b0C.":[143],"has":[147],"potential":[149],"measurement":[155],"mobile":[157],"patients.":[158],"next":[160],"steps":[161],"include":[162],"testing":[163],"in":[166],"environment":[169],"validating":[171],"respect":[174],"standard":[176],"sensors,":[180],"such":[181],"esophageal":[183],"rectal":[185],"probes.":[186]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
