{"id":"https://openalex.org/W2290105483","doi":"https://doi.org/10.1109/bmei.2015.7401468","title":"The magnetic induction tomography measurement system based on Helmholtz coil","display_name":"The magnetic induction tomography measurement system based on Helmholtz coil","publication_year":2015,"publication_date":"2015-10-01","ids":{"openalex":"https://openalex.org/W2290105483","doi":"https://doi.org/10.1109/bmei.2015.7401468","mag":"2290105483"},"language":"en","primary_location":{"id":"doi:10.1109/bmei.2015.7401468","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bmei.2015.7401468","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090227637","display_name":"Haijun Luo","orcid":"https://orcid.org/0000-0002-2723-5833"},"institutions":[{"id":"https://openalex.org/I126924076","display_name":"Chongqing Normal University","ror":"https://ror.org/01dcw5w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I126924076"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Haijun Luo","raw_affiliation_strings":["College of Physics and Electronic engineering, Chongqing Normal University, Chongqing, China"],"affiliations":[{"raw_affiliation_string":"College of Physics and Electronic engineering, Chongqing Normal University, Chongqing, China","institution_ids":["https://openalex.org/I126924076"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101697179","display_name":"Xin Jiang","orcid":"https://orcid.org/0000-0003-3814-7414"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xin Jiang","raw_affiliation_strings":["Community Health Service Centers, Chongqing, China"],"affiliations":[{"raw_affiliation_string":"Community Health Service Centers, Chongqing, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5090227637"],"corresponding_institution_ids":["https://openalex.org/I126924076"],"apc_list":null,"apc_paid":null,"fwci":0.3946,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.68667799,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"32","issue":null,"first_page":"29","last_page":"33"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11205","display_name":"Numerical methods in inverse problems","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2610","display_name":"Mathematical Physics"},"field":{"id":"https://openalex.org/fields/26","display_name":"Mathematics"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.992900013923645,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.6831867098808289},{"id":"https://openalex.org/keywords/helmholtz-coil","display_name":"Helmholtz coil","score":0.638698399066925},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.5863882303237915},{"id":"https://openalex.org/keywords/excitation","display_name":"Excitation","score":0.5860560536384583},{"id":"https://openalex.org/keywords/biomagnetism","display_name":"Biomagnetism","score":0.5696731209754944},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5687727928161621},{"id":"https://openalex.org/keywords/electromagnetic-induction","display_name":"Electromagnetic induction","score":0.5404840707778931},{"id":"https://openalex.org/keywords/tomography","display_name":"Tomography","score":0.48984000086784363},{"id":"https://openalex.org/keywords/spiral","display_name":"Spiral (railway)","score":0.4786449670791626},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.4771273136138916},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.4608231782913208},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.45369911193847656},{"id":"https://openalex.org/keywords/search-coil","display_name":"Search coil","score":0.45054376125335693},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.4239910840988159},{"id":"https://openalex.org/keywords/helmholtz-free-energy","display_name":"Helmholtz free energy","score":0.4229174852371216},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.3135174810886383},{"id":"https://openalex.org/keywords/magnetic-flux","display_name":"Magnetic flux","score":0.25000596046447754},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.2326968014240265},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.16634267568588257},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1101635992527008}],"concepts":[{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.6831867098808289},{"id":"https://openalex.org/C2778252132","wikidata":"https://www.wikidata.org/wiki/Q1603273","display_name":"Helmholtz coil","level":3,"score":0.638698399066925},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.5863882303237915},{"id":"https://openalex.org/C83581075","wikidata":"https://www.wikidata.org/wiki/Q1361503","display_name":"Excitation","level":2,"score":0.5860560536384583},{"id":"https://openalex.org/C78902741","wikidata":"https://www.wikidata.org/wiki/Q4915071","display_name":"Biomagnetism","level":3,"score":0.5696731209754944},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5687727928161621},{"id":"https://openalex.org/C102130693","wikidata":"https://www.wikidata.org/wiki/Q988780","display_name":"Electromagnetic induction","level":3,"score":0.5404840707778931},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.48984000086784363},{"id":"https://openalex.org/C174128100","wikidata":"https://www.wikidata.org/wiki/Q846907","display_name":"Spiral (railway)","level":2,"score":0.4786449670791626},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.4771273136138916},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4608231782913208},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.45369911193847656},{"id":"https://openalex.org/C63236149","wikidata":"https://www.wikidata.org/wiki/Q635465","display_name":"Search coil","level":4,"score":0.45054376125335693},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.4239910840988159},{"id":"https://openalex.org/C27592594","wikidata":"https://www.wikidata.org/wiki/Q865821","display_name":"Helmholtz free energy","level":2,"score":0.4229174852371216},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3135174810886383},{"id":"https://openalex.org/C157479481","wikidata":"https://www.wikidata.org/wiki/Q177831","display_name":"Magnetic flux","level":3,"score":0.25000596046447754},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2326968014240265},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.16634267568588257},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1101635992527008},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bmei.2015.7401468","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bmei.2015.7401468","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","score":0.6800000071525574,"display_name":"Clean water and sanitation"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2158591481","https://openalex.org/W2166574598","https://openalex.org/W2348418259","https://openalex.org/W2371388652","https://openalex.org/W6705262130"],"related_works":["https://openalex.org/W2064622645","https://openalex.org/W3009413735","https://openalex.org/W2348247736","https://openalex.org/W2348377862","https://openalex.org/W2388016850","https://openalex.org/W2990176795","https://openalex.org/W2995232673","https://openalex.org/W2348418259","https://openalex.org/W2903929425","https://openalex.org/W4313890941"],"abstract_inverted_index":{"Magnetic":[0],"induction":[1],"tomography":[2],"(MIT)":[3],"is":[4,17,61,83,123],"a":[5,41],"contactless":[6],"measurement":[7],"of":[8,25,28,43,51,69,74,106,109,116],"biological":[9],"tissue":[10],"conductivity":[11,108],"imaging":[12],"technique.":[13],"The":[14,76,95],"spiral":[15],"coil":[16,37],"widely":[18],"used,":[19],"which":[20,38],"leads":[21],"to":[22],"the":[23,29,35,49,57,67,87,90,104,107,114,117,121,127],"nonuniformity":[24],"sensitivity":[26],"distribution":[27],"detection":[30],"signal.":[31],"This":[32],"paper":[33],"proposed":[34],"Helmholtz":[36],"can":[39,102],"generate":[40],"set":[42],"uniform":[44],"excitation":[45,52],"fields,":[46],"and":[47,71,93,112],"analyzed":[48],"uniformity":[50],"field.":[53],"In":[54],"MIT":[55],"system,":[56],"exciting":[58,72],"magnetic":[59],"field":[60],"generated":[62],"through":[63],"sine-wave":[64],"current,":[65],"with":[66,126],"frequency":[68],"10MHz":[70],"current":[73],"20mA.":[75],"experimental":[77],"physics":[78],"model":[79],"simulated":[80],"cerebral":[81],"hemorrhage":[82],"produced":[84],"by":[85],"using":[86],"distilled":[88],"water,":[89],"agar":[91],"powder":[92],"NaCl.":[94],"result":[96],"experiments":[97],"show":[98],"that":[99],"this":[100],"system":[101],"test":[103],"changes":[105],"partial":[110],"tissues,":[111],"reflect":[113],"position":[115],"foreign":[118],"matter,":[119],"but":[120],"image":[122],"enlarged":[124],"compared":[125],"actual":[128],"one.":[129]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
