{"id":"https://openalex.org/W2163763483","doi":"https://doi.org/10.1109/bmei.2009.5305721","title":"Research on Non-Invasive Arterial Pulse Sensor and Detecting System","display_name":"Research on Non-Invasive Arterial Pulse Sensor and Detecting System","publication_year":2009,"publication_date":"2009-01-01","ids":{"openalex":"https://openalex.org/W2163763483","doi":"https://doi.org/10.1109/bmei.2009.5305721","mag":"2163763483"},"language":"en","primary_location":{"id":"doi:10.1109/bmei.2009.5305721","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bmei.2009.5305721","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 2nd International Conference on Biomedical Engineering and Informatics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100364480","display_name":"Lu Wang","orcid":"https://orcid.org/0000-0002-7912-2021"},"institutions":[{"id":"https://openalex.org/I55022517","display_name":"Heilongjiang University","ror":"https://ror.org/04zyhq975","country_code":"CN","type":"education","lineage":["https://openalex.org/I55022517"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Lu Wang","raw_affiliation_strings":["Key Laboratory of Electronics Engineering, College of Heilongjiang Province, Major Laboratories of Integrated Circuits, Heilongjiang University, Harbin, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Electronics Engineering, College of Heilongjiang Province, Major Laboratories of Integrated Circuits, Heilongjiang University, Harbin, China","institution_ids":["https://openalex.org/I55022517"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108559860","display_name":"Dianzhong Wen","orcid":null},"institutions":[{"id":"https://openalex.org/I55022517","display_name":"Heilongjiang University","ror":"https://ror.org/04zyhq975","country_code":"CN","type":"education","lineage":["https://openalex.org/I55022517"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dianzhong Wen","raw_affiliation_strings":["Key Laboratory of Electronics Engineering, College of Heilongjiang Province, Major Laboratories of Integrated Circuits, Heilongjiang University, Harbin, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Electronics Engineering, College of Heilongjiang Province, Major Laboratories of Integrated Circuits, Heilongjiang University, Harbin, China","institution_ids":["https://openalex.org/I55022517"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5100364480"],"corresponding_institution_ids":["https://openalex.org/I55022517"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.23545361,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"30","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9969000220298767,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9459999799728394,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.7498457431793213},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5663476586341858},{"id":"https://openalex.org/keywords/microelectromechanical-systems","display_name":"Microelectromechanical systems","score":0.5629369020462036},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.531672477722168},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4404739737510681},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.4375791549682617},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3762103319168091},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.35106292366981506},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.2046753168106079},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19694200158119202},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.1647104024887085},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14491260051727295}],"concepts":[{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.7498457431793213},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5663476586341858},{"id":"https://openalex.org/C37977207","wikidata":"https://www.wikidata.org/wiki/Q175561","display_name":"Microelectromechanical systems","level":2,"score":0.5629369020462036},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.531672477722168},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4404739737510681},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.4375791549682617},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3762103319168091},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.35106292366981506},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2046753168106079},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19694200158119202},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1647104024887085},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14491260051727295}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bmei.2009.5305721","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bmei.2009.5305721","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 2nd International Conference on Biomedical Engineering and Informatics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.5699999928474426,"display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1502154493","https://openalex.org/W1994076864","https://openalex.org/W2000365658","https://openalex.org/W2006062168","https://openalex.org/W2167958724","https://openalex.org/W2358070648","https://openalex.org/W6630095146"],"related_works":["https://openalex.org/W2272290532","https://openalex.org/W2120483398","https://openalex.org/W1530711136","https://openalex.org/W1763916368","https://openalex.org/W2319192085","https://openalex.org/W2391127530","https://openalex.org/W2045074154","https://openalex.org/W2346208161","https://openalex.org/W2974943474","https://openalex.org/W2393343784"],"abstract_inverted_index":{"The":[0,46,60],"arterial":[1,16,22,47,64],"pulse":[2,17,23,48,58,65],"monitoring":[3],"is":[4,67],"significant":[5],"in":[6],"assessment":[7],"of":[8,15,27,62],"cardiovascular":[9],"system.":[10],"To":[11],"improve":[12],"the":[13,63],"performance":[14],"sensor,":[18],"a":[19,28],"new":[20],"non-invasive":[21],"detecting":[24,41,49],"system":[25,50],"composed":[26],"nc-Si:H/c-Si":[29],"heterojunction":[30],"MOSFET":[31],"pressure":[32],"sensor":[33,66],"fabricated":[34],"by":[35],"micro-electromechanical":[36],"systems":[37],"(MEMS)":[38],"technology":[39],"and":[40,56],"circuits":[42],"has":[43],"been":[44],"developed.":[45],"can":[51],"simultaneously":[52],"detect,":[53],"display,":[54],"store":[55],"analyze":[57],"signals.":[59],"sensitivity":[61],"0.45":[68],"mV/kPa.":[69]},"counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
