{"id":"https://openalex.org/W3094166828","doi":"https://doi.org/10.1109/biorob49111.2020.9224278","title":"An Integrated, Back-Drivable Electro-Hydrostatic Actuator for a Knee Prosthesis","display_name":"An Integrated, Back-Drivable Electro-Hydrostatic Actuator for a Knee Prosthesis","publication_year":2020,"publication_date":"2020-10-15","ids":{"openalex":"https://openalex.org/W3094166828","doi":"https://doi.org/10.1109/biorob49111.2020.9224278","mag":"3094166828"},"language":"en","primary_location":{"id":"doi:10.1109/biorob49111.2020.9224278","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biorob49111.2020.9224278","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 8th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064749168","display_name":"Federico Tessari","orcid":"https://orcid.org/0000-0002-3079-0643"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]},{"id":"https://openalex.org/I30771326","display_name":"Italian Institute of Technology","ror":"https://ror.org/042t93s57","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Federico Tessari","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy","Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy","institution_ids":["https://openalex.org/I177477856"]},{"raw_affiliation_string":"Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy","institution_ids":["https://openalex.org/I30771326"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078139026","display_name":"Renato Galluzzi","orcid":"https://orcid.org/0000-0001-6125-8222"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Renato Galluzzi","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049216939","display_name":"Andrea Tonoli","orcid":"https://orcid.org/0000-0001-6621-5037"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Andrea Tonoli","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091427366","display_name":"Nicola Amati","orcid":"https://orcid.org/0000-0002-3380-9346"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Nicola Amati","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Corso Duca degli Abruzzi, 24, Torino, TO, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027722045","display_name":"Giovanni Milandri","orcid":null},"institutions":[{"id":"https://openalex.org/I30771326","display_name":"Italian Institute of Technology","ror":"https://ror.org/042t93s57","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giovanni Milandri","raw_affiliation_strings":["Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy"],"affiliations":[{"raw_affiliation_string":"Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy","institution_ids":["https://openalex.org/I30771326"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029456664","display_name":"Matteo Laffranchi","orcid":"https://orcid.org/0000-0003-1189-281X"},"institutions":[{"id":"https://openalex.org/I30771326","display_name":"Italian Institute of Technology","ror":"https://ror.org/042t93s57","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Matteo Laffranchi","raw_affiliation_strings":["Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy"],"affiliations":[{"raw_affiliation_string":"Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy","institution_ids":["https://openalex.org/I30771326"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045739907","display_name":"Lorenzo De Michieli","orcid":"https://orcid.org/0000-0001-7158-3002"},"institutions":[{"id":"https://openalex.org/I30771326","display_name":"Italian Institute of Technology","ror":"https://ror.org/042t93s57","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Lorenzo De Michieli","raw_affiliation_strings":["Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy"],"affiliations":[{"raw_affiliation_string":"Rehab Technologies, Italian Institute of Technology Via Morego, 30, Genova, GE, Italy","institution_ids":["https://openalex.org/I30771326"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5064749168"],"corresponding_institution_ids":["https://openalex.org/I177477856","https://openalex.org/I30771326"],"apc_list":null,"apc_paid":null,"fwci":0.3643,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.5721907,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"136","issue":null,"first_page":"708","last_page":"714"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.8689355850219727},{"id":"https://openalex.org/keywords/admittance","display_name":"Admittance","score":0.5537906885147095},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5312107801437378},{"id":"https://openalex.org/keywords/perspective","display_name":"Perspective (graphical)","score":0.4923504590988159},{"id":"https://openalex.org/keywords/electro-hydraulic-actuator","display_name":"Electro-hydraulic actuator","score":0.4874248802661896},{"id":"https://openalex.org/keywords/artificial-limbs","display_name":"Artificial limbs","score":0.4860847294330597},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.45639675855636597},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4038572907447815},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.34042996168136597},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.32854437828063965},{"id":"https://openalex.org/keywords/prosthesis","display_name":"Prosthesis","score":0.22781136631965637},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.17065495252609253},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.14998042583465576},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12555280327796936}],"concepts":[{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.8689355850219727},{"id":"https://openalex.org/C108811297","wikidata":"https://www.wikidata.org/wiki/Q214518","display_name":"Admittance","level":3,"score":0.5537906885147095},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5312107801437378},{"id":"https://openalex.org/C12713177","wikidata":"https://www.wikidata.org/wiki/Q1900281","display_name":"Perspective (graphical)","level":2,"score":0.4923504590988159},{"id":"https://openalex.org/C53432115","wikidata":"https://www.wikidata.org/wiki/Q5357907","display_name":"Electro-hydraulic actuator","level":3,"score":0.4874248802661896},{"id":"https://openalex.org/C2987467780","wikidata":"https://www.wikidata.org/wiki/Q181802","display_name":"Artificial limbs","level":3,"score":0.4860847294330597},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.45639675855636597},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4038572907447815},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.34042996168136597},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.32854437828063965},{"id":"https://openalex.org/C2778715743","wikidata":"https://www.wikidata.org/wiki/Q181802","display_name":"Prosthesis","level":2,"score":0.22781136631965637},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.17065495252609253},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.14998042583465576},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12555280327796936}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/biorob49111.2020.9224278","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biorob49111.2020.9224278","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 8th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1590311443","https://openalex.org/W1993377949","https://openalex.org/W2024919474","https://openalex.org/W2028575366","https://openalex.org/W2040722147","https://openalex.org/W2047654934","https://openalex.org/W2048087183","https://openalex.org/W2058968833","https://openalex.org/W2075056395","https://openalex.org/W2078457597","https://openalex.org/W2083113971","https://openalex.org/W2086889378","https://openalex.org/W2089292826","https://openalex.org/W2111904757","https://openalex.org/W2124641719","https://openalex.org/W2142363007","https://openalex.org/W2150890789","https://openalex.org/W2157822690","https://openalex.org/W2238575034","https://openalex.org/W2538046394","https://openalex.org/W2541894311","https://openalex.org/W2556407872","https://openalex.org/W2742504415","https://openalex.org/W2772313598","https://openalex.org/W2884830154","https://openalex.org/W2986893618","https://openalex.org/W4211003818","https://openalex.org/W6657503591","https://openalex.org/W6728751708"],"related_works":["https://openalex.org/W2092911180","https://openalex.org/W1529731471","https://openalex.org/W4233104623","https://openalex.org/W2294659468","https://openalex.org/W2089292826","https://openalex.org/W2914218493","https://openalex.org/W2083581997","https://openalex.org/W1970099472","https://openalex.org/W2120607243","https://openalex.org/W2674548929"],"abstract_inverted_index":{"This":[0],"paper":[1],"focuses":[2],"on":[3],"the":[4,23,45,67,70,75,103,107,112,115],"analysis,":[5],"development":[6],"and":[7,30,36,96,118],"experimental":[8],"evaluation":[9,101],"of":[10,47,69,102,114],"an":[11],"electro-hydrostatic":[12],"actuator":[13,32],"for":[14],"knee":[15],"prosthetic":[16],"devices.":[17],"In":[18],"contrast":[19],"to":[20,26,79,92,97,105],"traditional":[21],"actuation,":[22],"goal":[24],"is":[25,42,77,90],"obtain":[27],"a":[28,49,59,81,85,99],"highly-integrated":[29],"back-drivable":[31],"with":[33,44],"both":[34],"active":[35,123],"regenerative":[37],"capabilities.":[38],"A":[39],"design":[40],"procedure":[41],"established":[43],"purpose":[46],"yielding":[48],"fully-customized":[50],"compact":[51],"actuation":[52,71,94],"unit.":[53],"Specifications":[54],"are":[55,64],"defined":[56],"initially":[57],"from":[58],"biomechanical":[60],"perspective.":[61],"Further":[62],"constraints":[63],"imposed":[65],"by":[66],"limitations":[68],"system":[72],"components.":[73],"Then,":[74],"methodology":[76],"applied":[78],"develop":[80],"custom":[82],"prototype.":[83],"From":[84],"control":[86,89],"standpoint,":[87],"admittance":[88],"implemented":[91],"show":[93],"functionality":[95],"make":[98],"preliminary":[100],"ability":[104],"suit":[106],"application.":[108],"Experimental":[109],"results":[110],"demonstrate":[111],"validation":[113],"proposed":[116],"technology":[117],"its":[119],"high":[120],"potential":[121],"in":[122],"prostheses":[124],"applications.":[125]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
