{"id":"https://openalex.org/W2397561766","doi":"https://doi.org/10.1109/bioms.2011.6052382","title":"ECG biometric authentication using Pulse Active Width (PAW)","display_name":"ECG biometric authentication using Pulse Active Width (PAW)","publication_year":2011,"publication_date":"2011-09-01","ids":{"openalex":"https://openalex.org/W2397561766","doi":"https://doi.org/10.1109/bioms.2011.6052382","mag":"2397561766"},"language":"en","primary_location":{"id":"doi:10.1109/bioms.2011.6052382","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bioms.2011.6052382","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021971394","display_name":"Sairul Izwan Safie","orcid":"https://orcid.org/0000-0003-1079-5014"},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Sairul I Safie","raw_affiliation_strings":["Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017455396","display_name":"John J. Soraghan","orcid":"https://orcid.org/0000-0003-4418-7391"},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"John J Soraghan","raw_affiliation_strings":["Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049987982","display_name":"Lykourgos Petropoulakis","orcid":null},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Lykourgos Petropoulakis","raw_affiliation_strings":["Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Excellence in Signal and Image Processing (CeSIP), University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7919,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.78074857,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9921000003814697,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.984499990940094,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/biometrics","display_name":"Biometrics","score":0.829034149646759},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.656535267829895},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.6479546427726746},{"id":"https://openalex.org/keywords/feature-extraction","display_name":"Feature extraction","score":0.6122249960899353},{"id":"https://openalex.org/keywords/authentication","display_name":"Authentication (law)","score":0.5903168320655823},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.5219228267669678},{"id":"https://openalex.org/keywords/word-error-rate","display_name":"Word error rate","score":0.5132005214691162},{"id":"https://openalex.org/keywords/pulse-rate","display_name":"Pulse rate","score":0.4774211645126343},{"id":"https://openalex.org/keywords/feature","display_name":"Feature (linguistics)","score":0.4675271511077881},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.45933806896209717},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1854211688041687},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.08272436261177063},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.06657955050468445},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.05930432677268982},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.05520504713058472}],"concepts":[{"id":"https://openalex.org/C184297639","wikidata":"https://www.wikidata.org/wiki/Q177765","display_name":"Biometrics","level":2,"score":0.829034149646759},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.656535267829895},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.6479546427726746},{"id":"https://openalex.org/C52622490","wikidata":"https://www.wikidata.org/wiki/Q1026626","display_name":"Feature extraction","level":2,"score":0.6122249960899353},{"id":"https://openalex.org/C148417208","wikidata":"https://www.wikidata.org/wiki/Q4825882","display_name":"Authentication (law)","level":2,"score":0.5903168320655823},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5219228267669678},{"id":"https://openalex.org/C40969351","wikidata":"https://www.wikidata.org/wiki/Q3516228","display_name":"Word error rate","level":2,"score":0.5132005214691162},{"id":"https://openalex.org/C2988351347","wikidata":"https://www.wikidata.org/wiki/Q191733","display_name":"Pulse rate","level":3,"score":0.4774211645126343},{"id":"https://openalex.org/C2776401178","wikidata":"https://www.wikidata.org/wiki/Q12050496","display_name":"Feature (linguistics)","level":2,"score":0.4675271511077881},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.45933806896209717},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1854211688041687},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.08272436261177063},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.06657955050468445},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.05930432677268982},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.05520504713058472},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bioms.2011.6052382","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bioms.2011.6052382","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1655694665","https://openalex.org/W2006873322","https://openalex.org/W2026557884","https://openalex.org/W2034236319","https://openalex.org/W2042087214","https://openalex.org/W2063358975","https://openalex.org/W2069391763","https://openalex.org/W2071990626","https://openalex.org/W2134075215","https://openalex.org/W2134566476","https://openalex.org/W2134577338","https://openalex.org/W2136696710","https://openalex.org/W2140959843","https://openalex.org/W2147380014","https://openalex.org/W2162359957","https://openalex.org/W2162800060","https://openalex.org/W2170416874","https://openalex.org/W2170941890","https://openalex.org/W2535940264","https://openalex.org/W2544984498","https://openalex.org/W3197578054"],"related_works":["https://openalex.org/W2076845124","https://openalex.org/W2183964146","https://openalex.org/W2379932303","https://openalex.org/W3147744369","https://openalex.org/W4241440711","https://openalex.org/W2211301776","https://openalex.org/W1995418324","https://openalex.org/W3104966193","https://openalex.org/W2060905804","https://openalex.org/W1485853333"],"abstract_inverted_index":{"This":[0,21],"paper":[1],"presents":[2],"a":[3],"new":[4],"feature":[5,86],"extraction":[6,87],"method":[7,22,82],"known":[8],"as":[9,58],"Pulse":[10,30],"Active":[11],"Width":[12,31],"(PAW)":[13],"implemented":[14],"on":[15,26],"electrocardiogram":[16],"(ECG)":[17],"for":[18],"biometric":[19],"authentication.":[20],"is":[23,77],"developed":[24],"based":[25],"the":[27,44,52,59,74,80],"concept":[28],"of":[29,36],"Modulation":[32],"(PWM).":[33],"A":[34],"total":[35],"196":[37],"ECGs":[38],"from":[39,43],"98":[40],"subjects,":[41],"taken":[42],"Physikalisch-Technische":[45],"Bundesanstalt":[46],"(PTB)":[47],"database":[48],"are":[49,69],"used":[50,71],"in":[51],"simulations.":[53],"Biometric":[54],"performance":[55],"profile":[56],"such":[57],"area":[60],"under":[61],"ROC":[62],"(AUR)":[63],"and":[64],"equal":[65],"error":[66],"rate":[67],"(EER)":[68],"then":[70],"to":[72],"evaluate":[73],"results.":[75],"It":[76],"shown":[78],"that":[79],"PAW":[81],"outperforms":[83],"conventional":[84],"temporal":[85],"techniques.":[88]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
