{"id":"https://openalex.org/W4309270020","doi":"https://doi.org/10.1109/biocas54905.2022.9948626","title":"An 11 V-tolerant, high-density neurostimulator using time-domain calibration in 65 nm CMOS","display_name":"An 11 V-tolerant, high-density neurostimulator using time-domain calibration in 65 nm CMOS","publication_year":2022,"publication_date":"2022-10-13","ids":{"openalex":"https://openalex.org/W4309270020","doi":"https://doi.org/10.1109/biocas54905.2022.9948626"},"language":"en","primary_location":{"id":"doi:10.1109/biocas54905.2022.9948626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas54905.2022.9948626","pdf_url":null,"source":{"id":"https://openalex.org/S4363608179","display_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://lirias.kuleuven.be/retrieve/32cb88bf-5662-436b-8523-e42d634c8ba5","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081436844","display_name":"Maxime Feyerick","orcid":"https://orcid.org/0000-0001-5485-8035"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Maxime Feyerick","raw_affiliation_strings":["ESAT-MICAS,KU Leuven,Leuven,Belgium,3001"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ESAT-MICAS,KU Leuven,Leuven,Belgium,3001","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076274517","display_name":"Wim Dehaene","orcid":"https://orcid.org/0000-0002-6792-7965"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Wim Dehaene","raw_affiliation_strings":["ESAT-MICAS,KU Leuven,Leuven,Belgium,3001"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ESAT-MICAS,KU Leuven,Leuven,Belgium,3001","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I99464096"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"429","last_page":"433"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.823100209236145},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.6101728677749634},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6049241423606873},{"id":"https://openalex.org/keywords/time-domain","display_name":"Time domain","score":0.5763757228851318},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.5164661407470703},{"id":"https://openalex.org/keywords/amplitude","display_name":"Amplitude","score":0.48085933923721313},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.47360777854919434},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.45065000653266907},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.40250036120414734},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39029791951179504},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2662140130996704},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20062041282653809},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.08752664923667908}],"concepts":[{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.823100209236145},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.6101728677749634},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6049241423606873},{"id":"https://openalex.org/C103824480","wikidata":"https://www.wikidata.org/wiki/Q185889","display_name":"Time domain","level":2,"score":0.5763757228851318},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.5164661407470703},{"id":"https://openalex.org/C180205008","wikidata":"https://www.wikidata.org/wiki/Q159190","display_name":"Amplitude","level":2,"score":0.48085933923721313},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47360777854919434},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.45065000653266907},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.40250036120414734},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39029791951179504},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2662140130996704},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20062041282653809},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.08752664923667908},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/biocas54905.2022.9948626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas54905.2022.9948626","pdf_url":null,"source":{"id":"https://openalex.org/S4363608179","display_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:20.500.12942/707495","is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/20.500.12942/707495","pdf_url":"https://lirias.kuleuven.be/retrieve/32cb88bf-5662-436b-8523-e42d634c8ba5","source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS), Taiwan, 13-15 October 2022","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:lirias2repo.kuleuven.be:20.500.12942/707495","is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/20.500.12942/707495","pdf_url":"https://lirias.kuleuven.be/retrieve/32cb88bf-5662-436b-8523-e42d634c8ba5","source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS), Taiwan, 13-15 October 2022","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4309270020.pdf","grobid_xml":"https://content.openalex.org/works/W4309270020.grobid-xml"},"referenced_works_count":20,"referenced_works":["https://openalex.org/W1542699763","https://openalex.org/W1966885893","https://openalex.org/W1971494066","https://openalex.org/W2073451535","https://openalex.org/W2090583902","https://openalex.org/W2101656718","https://openalex.org/W2107834717","https://openalex.org/W2112854909","https://openalex.org/W2137791946","https://openalex.org/W2148483191","https://openalex.org/W2153787766","https://openalex.org/W2319514052","https://openalex.org/W2791945743","https://openalex.org/W3119483195","https://openalex.org/W3170203354","https://openalex.org/W3199544981","https://openalex.org/W3207382873","https://openalex.org/W4205237820","https://openalex.org/W4205431456","https://openalex.org/W4248262636"],"related_works":["https://openalex.org/W1974895211","https://openalex.org/W2129841057","https://openalex.org/W3040712279","https://openalex.org/W2364769705","https://openalex.org/W2056136368","https://openalex.org/W2374664672","https://openalex.org/W4367555392","https://openalex.org/W2176409448","https://openalex.org/W2024367938","https://openalex.org/W2898383381"],"abstract_inverted_index":{"Safe":[0],"neurostimulation":[1],"requires":[2],"accurate":[3],"charge":[4,12],"balancing":[5],"of":[6],"the":[7,15,28,35,45,63,101],"stimulation":[8],"waveform":[9],"to":[10,26,61],"avoid":[11],"build-up":[13],"on":[14,110],"electrode-tissue":[16],"interface.":[17],"This":[18],"work":[19],"presents":[20],"a":[21,77],"novel":[22],"time-domain":[23],"calibration":[24,99],"scheme":[25],"reduce":[27],"on-chip":[29],"area":[30],"per":[31,119],"channel:":[32],"control":[33],"in":[34,40,44,57,76],"amplitude":[36],"domain":[37],"is":[38,104,116],"loosened":[39],"exchange":[41],"for":[42,87,94],"corrections":[43],"time":[46],"domain,":[47],"relieving":[48],"analog":[49],"matching":[50],"constraints.":[51],"A":[52],"16-channel":[53],"stimulator":[54],"was":[55],"implemented":[56,75],"65":[58],"nm":[59],"CMOS":[60,79],"validate":[62],"principle,":[64],"requiring":[65],"only":[66],"0.0141":[67],"mm":[68],"<sup":[69],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[70],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">2</sup>":[71],"area/channel.":[72],"Despite":[73],"being":[74],"standard":[78],"technology,":[80],"10.4":[81],"V":[82],"compliance":[83],"has":[84],"been":[85],"achieved":[86],"compatibility":[88],"with":[89],"high-impedant":[90],"microelectrode":[91],"arrays":[92],"typical":[93],"high-resolution":[95],"neurostimulators.":[96],"Measurements":[97],"after":[98],"show":[100],"DC":[102],"error":[103],"successfully":[105],"reduced":[106],"below":[107],"60":[108],"nA":[109],"every":[111],"channel.":[112,120],"Static":[113],"power":[114],"consumption":[115],"22.4":[117],"\u00b5W":[118]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
