{"id":"https://openalex.org/W4309263354","doi":"https://doi.org/10.1109/biocas54905.2022.9948600","title":"A Miniaturized Transcutaneous Carbon Dioxide Monitor Based on Dual Lifetime Referencing","display_name":"A Miniaturized Transcutaneous Carbon Dioxide Monitor Based on Dual Lifetime Referencing","publication_year":2022,"publication_date":"2022-10-13","ids":{"openalex":"https://openalex.org/W4309263354","doi":"https://doi.org/10.1109/biocas54905.2022.9948600"},"language":"en","primary_location":{"id":"doi:10.1109/biocas54905.2022.9948600","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas54905.2022.9948600","pdf_url":null,"source":{"id":"https://openalex.org/S4363608179","display_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059290570","display_name":"Tuna B. Tufan","orcid":"https://orcid.org/0000-0001-6905-1576"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Tuna B. Tufan","raw_affiliation_strings":["Worcester Polytechnic Institute,Electrical and Computer Engineering,Worcester,MA 01609"],"affiliations":[{"raw_affiliation_string":"Worcester Polytechnic Institute,Electrical and Computer Engineering,Worcester,MA 01609","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5031435587","display_name":"\u00dclk\u00fchan G\u00fcler","orcid":"https://orcid.org/0000-0002-4723-4424"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ulkuhan Guler","raw_affiliation_strings":["Worcester Polytechnic Institute,Electrical and Computer Engineering,Worcester,MA 01609"],"affiliations":[{"raw_affiliation_string":"Worcester Polytechnic Institute,Electrical and Computer Engineering,Worcester,MA 01609","institution_ids":["https://openalex.org/I107077323"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5059290570"],"corresponding_institution_ids":["https://openalex.org/I107077323"],"apc_list":null,"apc_paid":null,"fwci":2.2445,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.89423657,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"144","last_page":"148"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10143","display_name":"Chronic Obstructive Pulmonary Disease (COPD) Research","score":0.9864000082015991,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/carbon-dioxide","display_name":"Carbon dioxide","score":0.9003534317016602},{"id":"https://openalex.org/keywords/carbon-dioxide-sensor","display_name":"Carbon dioxide sensor","score":0.7870564460754395},{"id":"https://openalex.org/keywords/partial-pressure","display_name":"Partial pressure","score":0.5671058893203735},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5101423859596252},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4683263599872589},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.4181784689426422},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.39080366492271423},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.20884627103805542},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.18183284997940063},{"id":"https://openalex.org/keywords/oxygen","display_name":"Oxygen","score":0.15348407626152039}],"concepts":[{"id":"https://openalex.org/C530467964","wikidata":"https://www.wikidata.org/wiki/Q1997","display_name":"Carbon dioxide","level":2,"score":0.9003534317016602},{"id":"https://openalex.org/C113803762","wikidata":"https://www.wikidata.org/wiki/Q5037960","display_name":"Carbon dioxide sensor","level":3,"score":0.7870564460754395},{"id":"https://openalex.org/C68463220","wikidata":"https://www.wikidata.org/wiki/Q27165","display_name":"Partial pressure","level":3,"score":0.5671058893203735},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5101423859596252},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4683263599872589},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4181784689426422},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.39080366492271423},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20884627103805542},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.18183284997940063},{"id":"https://openalex.org/C540031477","wikidata":"https://www.wikidata.org/wiki/Q629","display_name":"Oxygen","level":2,"score":0.15348407626152039},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/biocas54905.2022.9948600","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas54905.2022.9948600","pdf_url":null,"source":{"id":"https://openalex.org/S4363608179","display_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","score":0.44999998807907104,"display_name":"Clean water and sanitation"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1602789896","https://openalex.org/W1964990013","https://openalex.org/W2201835369","https://openalex.org/W2314350043","https://openalex.org/W2491458126","https://openalex.org/W2898818399","https://openalex.org/W3018257432","https://openalex.org/W3082779101","https://openalex.org/W3097564282","https://openalex.org/W3109228218","https://openalex.org/W3117305607","https://openalex.org/W3122334817","https://openalex.org/W3163417018","https://openalex.org/W3175713954","https://openalex.org/W3181013774","https://openalex.org/W3183417544","https://openalex.org/W3204525376","https://openalex.org/W4200087685","https://openalex.org/W4200372773","https://openalex.org/W4206937922","https://openalex.org/W4210257803","https://openalex.org/W4280635619","https://openalex.org/W6745003846","https://openalex.org/W6797657150","https://openalex.org/W6807510230"],"related_works":["https://openalex.org/W1989715959","https://openalex.org/W4394856619","https://openalex.org/W4394841490","https://openalex.org/W2103576898","https://openalex.org/W2047018826","https://openalex.org/W4390993395","https://openalex.org/W2067448486","https://openalex.org/W2409053344","https://openalex.org/W4309263354","https://openalex.org/W2735601241"],"abstract_inverted_index":{"The":[0],"ability":[1],"to":[2,17,84],"monitor":[3,72],"blood":[4],"gases,":[5],"namely":[6],"oxy-gen":[7],"and":[8,21,42,58,79,127],"carbon":[9,32,47,51,70,90,113],"dioxide,":[10],"in":[11,19,120],"real-time":[12],"is":[13],"of":[14,31,44,89,112],"critical":[15],"importance":[16],"clinicians":[18],"diagnosing":[20],"treating":[22],"respiratory":[23],"disorders.":[24],"Transcutaneous":[25],"monitors":[26,39,53],"measure":[27],"the":[28,36,86,93,98,109,121],"partial":[29,87,110],"pressure":[30,88,111],"dioxide":[33,52,71,91,114],"diffused":[34],"from":[35],"skin.":[37],"These":[38],"are":[40],"noninvasive":[41],"capable":[43],"continuously":[45],"monitoring":[46],"dioxide.":[48],"Conventional":[49],"transcutaneous":[50,69],"require":[54],"a":[55,67,75],"heating":[56],"element":[57],"large":[59],"calibration":[60],"equipment":[61],"for":[62,102],"reliable":[63],"measurements.":[64],"We":[65,107],"propose":[66],"miniaturized":[68],"based":[73],"on":[74],"luminescence":[76],"sensing":[77],"film":[78],"dual":[80],"lifetime":[81],"referencing":[82],"technique":[83],"assess":[85],"within":[92],"0-75":[94],"mmHg":[95],"range,":[96],"covering":[97],"clinically":[99],"relevant":[100],"range":[101,123],"healthy":[103],"humans,":[104],"35-45":[105],"mmHg.":[106],"measured":[108],"with":[115],"less":[116],"than":[117],"~1.6%":[118],"error":[119],"given":[122],"without":[124],"any":[125],"post-processing":[126],"heating.":[128]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
