{"id":"https://openalex.org/W4200373272","doi":"https://doi.org/10.1109/biocas49922.2021.9645000","title":"Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays","display_name":"Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays","publication_year":2021,"publication_date":"2021-10-07","ids":{"openalex":"https://openalex.org/W4200373272","doi":"https://doi.org/10.1109/biocas49922.2021.9645000"},"language":"en","primary_location":{"id":"doi:10.1109/biocas49922.2021.9645000","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9645000","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5012710879","display_name":"Alexander Hofmann","orcid":"https://orcid.org/0000-0002-6940-6290"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Alexander Hofmann","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046040302","display_name":"Peggy Reich","orcid":"https://orcid.org/0000-0002-9595-0011"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Peggy Reich","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014981669","display_name":"Martin Grabmann","orcid":"https://orcid.org/0000-0002-1839-8745"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Grabmann","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102897374","display_name":"Georg Gl\u00e4ser","orcid":"https://orcid.org/0000-0002-7923-0284"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Georg Glaser","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059527605","display_name":"Alexander Rolapp","orcid":"https://orcid.org/0000-0003-2133-8177"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Alexander Rolapp","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002641915","display_name":"Marco Reinhard","orcid":"https://orcid.org/0000-0002-5370-8374"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Marco Reinhard","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050559667","display_name":"Eric Sch\u00e4fer","orcid":"https://orcid.org/0000-0003-2663-7272"},"institutions":[{"id":"https://openalex.org/I4210145956","display_name":"Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme","ror":"https://ror.org/0445d9h15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210145956"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Eric Schafer","raw_affiliation_strings":["IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany"],"affiliations":[{"raw_affiliation_string":"IMMS Institut f\u00fcr Mikroelektronik- und Mechatronik-Systeme gemeinn\u00fctzige GmbH (IMMS GmbH), Ilmenau, Germany","institution_ids":["https://openalex.org/I4210145956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023937535","display_name":"Max Trubenbach","orcid":"https://orcid.org/0000-0002-0314-3985"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Max Trubenbach","raw_affiliation_strings":["Senova Gesellschaft f\u00fcr Biowissenschaft und Technik mbH, Weimar, Germany"],"affiliations":[{"raw_affiliation_string":"Senova Gesellschaft f\u00fcr Biowissenschaft und Technik mbH, Weimar, Germany","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5052086265","display_name":"Friedrich Scholz","orcid":"https://orcid.org/0000-0002-2511-5328"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Friedrich Scholz","raw_affiliation_strings":["Senova Gesellschaft f\u00fcr Biowissenschaft und Technik mbH, Weimar, Germany"],"affiliations":[{"raw_affiliation_string":"Senova Gesellschaft f\u00fcr Biowissenschaft und Technik mbH, Weimar, Germany","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":9,"corresponding_author_ids":["https://openalex.org/A5012710879"],"corresponding_institution_ids":["https://openalex.org/I4210145956"],"apc_list":null,"apc_paid":null,"fwci":0.3844,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.49256791,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10207","display_name":"Advanced biosensing and bioanalysis techniques","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1312","display_name":"Molecular Biology"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11472","display_name":"Analytical Chemistry and Sensors","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1502","display_name":"Bioengineering"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.8232108354568481},{"id":"https://openalex.org/keywords/application-specific-integrated-circuit","display_name":"Application-specific integrated circuit","score":0.7742156982421875},{"id":"https://openalex.org/keywords/photodiode","display_name":"Photodiode","score":0.6655268669128418},{"id":"https://openalex.org/keywords/cmos-sensor","display_name":"CMOS sensor","score":0.557309627532959},{"id":"https://openalex.org/keywords/dynamic-range","display_name":"Dynamic range","score":0.4722950756549835},{"id":"https://openalex.org/keywords/miniaturization","display_name":"Miniaturization","score":0.46606236696243286},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.4634852707386017},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.4506351351737976},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.4341431260108948},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.39120060205459595},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.31558889150619507},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.28214210271835327},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.2636992037296295},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.224782794713974},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21726223826408386},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.20466122031211853}],"concepts":[{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.8232108354568481},{"id":"https://openalex.org/C77390884","wikidata":"https://www.wikidata.org/wiki/Q217302","display_name":"Application-specific integrated circuit","level":2,"score":0.7742156982421875},{"id":"https://openalex.org/C751236","wikidata":"https://www.wikidata.org/wiki/Q175943","display_name":"Photodiode","level":2,"score":0.6655268669128418},{"id":"https://openalex.org/C155512908","wikidata":"https://www.wikidata.org/wiki/Q210745","display_name":"CMOS sensor","level":3,"score":0.557309627532959},{"id":"https://openalex.org/C87133666","wikidata":"https://www.wikidata.org/wiki/Q1161699","display_name":"Dynamic range","level":2,"score":0.4722950756549835},{"id":"https://openalex.org/C57528182","wikidata":"https://www.wikidata.org/wiki/Q1271842","display_name":"Miniaturization","level":2,"score":0.46606236696243286},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4634852707386017},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.4506351351737976},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.4341431260108948},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.39120060205459595},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.31558889150619507},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28214210271835327},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2636992037296295},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.224782794713974},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21726223826408386},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.20466122031211853},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/biocas49922.2021.9645000","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9645000","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.6600000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1245263362","https://openalex.org/W2004803144","https://openalex.org/W2025369658","https://openalex.org/W2037931122","https://openalex.org/W2093451229","https://openalex.org/W2149860919","https://openalex.org/W2513485589","https://openalex.org/W2620607709","https://openalex.org/W2797636025","https://openalex.org/W2802351393","https://openalex.org/W2883172861","https://openalex.org/W2910536152","https://openalex.org/W2950819922","https://openalex.org/W2957813057","https://openalex.org/W3000957859","https://openalex.org/W3029326439","https://openalex.org/W3090824517"],"related_works":["https://openalex.org/W1968212605","https://openalex.org/W1983441360","https://openalex.org/W2788076043","https://openalex.org/W2792670813","https://openalex.org/W2010511003","https://openalex.org/W2106574814","https://openalex.org/W2065223761","https://openalex.org/W2053377655","https://openalex.org/W2158002277","https://openalex.org/W2025249826"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3,153],"present":[4],"a":[5,37,44,55,78,86,160,183,194],"filterless":[6,179],"time-resolved":[7],"fluorescence":[8,134],"(TRF)":[9],"measurement":[10,72],"system":[11,165],"with":[12,116,148,193],"an":[13],"optoelectronic":[14],"CMOS":[15,40,48,175],"sensor":[16,49,52,176],"for":[17,199],"highly":[18],"sensitive":[19],"readout":[20],"of":[21,70,102,138,188,191,196,202,212],"lateral":[22],"flow":[23],"assay":[24],"(LFA)":[25],"test":[26,144],"strips.":[27],"An":[28,91],"application":[29],"specific":[30],"integrated":[31],"circuit":[32],"(ASIC)":[33],"was":[34,96,205],"designed":[35],"in":[36,85],"standard":[38],"0.35-\u00b5m":[39],"technology":[41],"and":[42,74,120],"includes":[43],"5":[45,47],"\u00d7":[46,58],"array.":[50],"Each":[51],"pixel":[53],"contains":[54],"100":[56,59],"\u00b5m":[57,60],"photodiode":[61],"acting":[62],"as":[63,133,171],"signal":[64,122],"transducer.":[65],"For":[66],"the":[67,71,103,113,149,155,200,210,213],"precise":[68],"control":[69],"sequence":[73],"its":[75],"timing":[76],"regime,":[77],"microcode":[79],"engine":[80],"(MCE)":[81],"has":[82],"been":[83],"realized":[84],"field-programmable":[87],"gate":[88],"array":[89],"(FPGA).":[90],"active":[92],"LED":[93],"discharge":[94],"concept":[95],"implemented":[97],"to":[98,118,159],"prevent":[99],"long":[100],"afterglow":[101],"light":[104],"source":[105],"after":[106],"it":[107],"is":[108],"turned":[109],"off.":[110],"To":[111],"characterize":[112],"TRF":[114,150,157,180],"reader":[115,158,164,181],"respect":[117],"uniform":[119],"reproducible":[121],"intensities,":[123],"suitable":[124],"europium":[125,139],"(III)":[126],"[Eu":[127],"3+]":[128],"chelate":[129],"particles":[130],"were":[131,146],"used":[132],"standards.":[135],"Different":[136],"concentrations":[137],"based":[140,178],"nanoparticles":[141],"(NP)":[142],"on":[143],"strips":[145],"quantified":[147],"reader.":[151,216],"Furthermore,":[152],"compared":[154],"developed":[156],"commercial":[161,214],"colorimetric":[162],"LFA":[163,215],"using":[166],"human":[167],"C-reactive":[168],"protein":[169],"(hCRP)":[170],"model":[172],"analyte.":[173],"The":[174],"ASIC":[177],"showed":[182],"detection":[184],"dynamic":[185],"range":[186],"(DDR)":[187],"4":[189],"orders":[190],"magnitude":[192],"LoD":[195,211],"0.2":[197],"ng/ml":[198],"quantification":[201],"CRP,":[203],"which":[204],"3.5":[206],"times":[207],"better":[208],"than":[209]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
