{"id":"https://openalex.org/W4200235441","doi":"https://doi.org/10.1109/biocas49922.2021.9644959","title":"An Electronic Osteosynthesis Implant for Continuous Load Monitoring using a Strain Gauge","display_name":"An Electronic Osteosynthesis Implant for Continuous Load Monitoring using a Strain Gauge","publication_year":2021,"publication_date":"2021-10-07","ids":{"openalex":"https://openalex.org/W4200235441","doi":"https://doi.org/10.1109/biocas49922.2021.9644959"},"language":"en","primary_location":{"id":"doi:10.1109/biocas49922.2021.9644959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9644959","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005104161","display_name":"Christian Adam","orcid":"https://orcid.org/0000-0003-4271-1890"},"institutions":[{"id":"https://openalex.org/I159176309","display_name":"Universit\u00e4t Hamburg","ror":"https://ror.org/00g30e956","country_code":"DE","type":"education","lineage":["https://openalex.org/I159176309"]},{"id":"https://openalex.org/I884043246","display_name":"Hamburg University of Technology","ror":"https://ror.org/04bs1pb34","country_code":"DE","type":"education","lineage":["https://openalex.org/I884043246"]},{"id":"https://openalex.org/I4210116825","display_name":"Europa-Institut","ror":"https://ror.org/02dm92c46","country_code":"DE","type":"education","lineage":["https://openalex.org/I4210116825","https://openalex.org/I91712215"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Christian Adam","raw_affiliation_strings":["Innovations Medical GmbH, Tuttlingen, Germany","Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany","Osteosynthese-Institut GbR, Ahrensburg, Germany"],"affiliations":[{"raw_affiliation_string":"Innovations Medical GmbH, Tuttlingen, Germany","institution_ids":[]},{"raw_affiliation_string":"Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany","institution_ids":["https://openalex.org/I159176309","https://openalex.org/I884043246"]},{"raw_affiliation_string":"Osteosynthese-Institut GbR, Ahrensburg, Germany","institution_ids":["https://openalex.org/I4210116825"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063336002","display_name":"Tobias Barth","orcid":"https://orcid.org/0000-0002-9840-3865"},"institutions":[{"id":"https://openalex.org/I4210166958","display_name":"BG Klinikum Hamburg","ror":"https://ror.org/05jw2mx52","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210166958","https://openalex.org/I4405257299"]},{"id":"https://openalex.org/I159176309","display_name":"Universit\u00e4t Hamburg","ror":"https://ror.org/00g30e956","country_code":"DE","type":"education","lineage":["https://openalex.org/I159176309"]},{"id":"https://openalex.org/I884043246","display_name":"Hamburg University of Technology","ror":"https://ror.org/04bs1pb34","country_code":"DE","type":"education","lineage":["https://openalex.org/I884043246"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Tobias Barth","raw_affiliation_strings":["Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany","Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany","institution_ids":["https://openalex.org/I159176309","https://openalex.org/I884043246"]},{"raw_affiliation_string":"Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210166958"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5104387570","display_name":"Matthias M\u00fcnch","orcid":null},"institutions":[{"id":"https://openalex.org/I4210166958","display_name":"BG Klinikum Hamburg","ror":"https://ror.org/05jw2mx52","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210166958","https://openalex.org/I4405257299"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Matthias Munch","raw_affiliation_strings":["Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210166958"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108776207","display_name":"Klaus Seide","orcid":null},"institutions":[{"id":"https://openalex.org/I4210166958","display_name":"BG Klinikum Hamburg","ror":"https://ror.org/05jw2mx52","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210166958","https://openalex.org/I4405257299"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Klaus Seide","raw_affiliation_strings":["Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Sports Traumatology, BG Hospital Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210166958"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062673708","display_name":"Wolfgang H. Krautschncider","orcid":null},"institutions":[{"id":"https://openalex.org/I159176309","display_name":"Universit\u00e4t Hamburg","ror":"https://ror.org/00g30e956","country_code":"DE","type":"education","lineage":["https://openalex.org/I159176309"]},{"id":"https://openalex.org/I884043246","display_name":"Hamburg University of Technology","ror":"https://ror.org/04bs1pb34","country_code":"DE","type":"education","lineage":["https://openalex.org/I884043246"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Wolfgang H. Krautschncider","raw_affiliation_strings":["Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Integrated Circuits, Hamburg University of Technology, Hamburg, Germany","institution_ids":["https://openalex.org/I159176309","https://openalex.org/I884043246"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5005104161"],"corresponding_institution_ids":["https://openalex.org/I159176309","https://openalex.org/I4210116825","https://openalex.org/I884043246"],"apc_list":null,"apc_paid":null,"fwci":0.3852,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.48344371,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"25 7","issue":null,"first_page":"01","last_page":"06"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9902999997138977,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/osteosynthesis","display_name":"Osteosynthesis","score":0.7507869601249695},{"id":"https://openalex.org/keywords/strain-gauge","display_name":"Strain gauge","score":0.6787288188934326},{"id":"https://openalex.org/keywords/usability","display_name":"Usability","score":0.48221147060394287},{"id":"https://openalex.org/keywords/implant","display_name":"Implant","score":0.4801168441772461},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4659847617149353},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3910105228424072},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.33009445667266846},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21166446805000305},{"id":"https://openalex.org/keywords/orthodontics","display_name":"Orthodontics","score":0.21150413155555725},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.20119652152061462},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.13350355625152588}],"concepts":[{"id":"https://openalex.org/C2777304102","wikidata":"https://www.wikidata.org/wiki/Q1667915","display_name":"Osteosynthesis","level":2,"score":0.7507869601249695},{"id":"https://openalex.org/C60584519","wikidata":"https://www.wikidata.org/wiki/Q610723","display_name":"Strain gauge","level":2,"score":0.6787288188934326},{"id":"https://openalex.org/C170130773","wikidata":"https://www.wikidata.org/wiki/Q216378","display_name":"Usability","level":2,"score":0.48221147060394287},{"id":"https://openalex.org/C2781411149","wikidata":"https://www.wikidata.org/wiki/Q486975","display_name":"Implant","level":2,"score":0.4801168441772461},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4659847617149353},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3910105228424072},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.33009445667266846},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21166446805000305},{"id":"https://openalex.org/C29694066","wikidata":"https://www.wikidata.org/wiki/Q118301","display_name":"Orthodontics","level":1,"score":0.21150413155555725},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.20119652152061462},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.13350355625152588},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/biocas49922.2021.9644959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9644959","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},{"id":"pmh:oai:tore.tuhh.de:11420/11729","is_oa":false,"landing_page_url":"http://hdl.handle.net/11420/11729","pdf_url":null,"source":{"id":"https://openalex.org/S4306401751","display_name":"tub.dok (Hamburg University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I884043246","host_organization_name":"Hamburg University of Technology","host_organization_lineage":["https://openalex.org/I884043246"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W108377058","https://openalex.org/W643058322","https://openalex.org/W2013262537","https://openalex.org/W2038997721","https://openalex.org/W2040403236","https://openalex.org/W2052046606","https://openalex.org/W2156749085","https://openalex.org/W2283239130","https://openalex.org/W2402684499","https://openalex.org/W2604568440","https://openalex.org/W2745485575","https://openalex.org/W2887288801","https://openalex.org/W4205556338","https://openalex.org/W4230217856","https://openalex.org/W4296025535"],"related_works":["https://openalex.org/W2429057255","https://openalex.org/W2187546663","https://openalex.org/W148745890","https://openalex.org/W4389670110","https://openalex.org/W2611942503","https://openalex.org/W4315621326","https://openalex.org/W2899790217","https://openalex.org/W2598865957","https://openalex.org/W1576092969","https://openalex.org/W2524154428"],"abstract_inverted_index":{"The":[0,23,102,156],"utilization":[1],"of":[2,95,115,130,159],"strain":[3,109],"gauges":[4],"for":[5,31,38,57,99,118,170],"monitoring":[6,32],"the":[7,33,40,72,85,93,96,100,141,146],"applied":[8],"mechanical":[9],"load":[10],"to":[11,27,82],"osteosynthesis":[12,48,168],"plates":[13,169],"using":[14],"electronic":[15,47],"implants":[16],"was":[17,25],"reported":[18],"several":[19],"times":[20],"in":[21,132,153],"literature.":[22],"technique":[24],"found":[26],"provide":[28],"valuable":[29],"information":[30],"fracture":[34],"healing":[35],"process":[36],"and":[37,78,107],"improving":[39],"rehabilitation.":[41],"This":[42,91],"paper":[43],"introduces":[44],"a":[45,63,112,154],"new":[46],"implant,":[49],"which":[50,74],"uses":[51],"supercapacitors":[52],"as":[53],"an":[54],"energy":[55,66],"storage":[56],"short":[58],"term":[59],"autonomous":[60],"operation.":[61],"Moreover,":[62],"bluetooth":[64],"low":[65],"(BLE)":[67],"transceiver":[68],"is":[69,79,148],"integrated":[70],"into":[71],"system,":[73],"covers":[75],"larger":[76,171],"distances":[77],"less":[80],"sensitive":[81],"misalignment":[83],"than":[84,120,127],"commonly":[86],"used":[87],"inductive":[88],"data":[89,143],"transmission.":[90],"improves":[92],"usability":[94],"proposed":[97],"system":[98,103],"patients.":[101],"can":[104,137],"continuously":[105],"sample":[106],"transmit":[108],"values":[110],"at":[111],"sampling":[113],"rate":[114],"5":[116,150],"Hz":[117],"more":[119],"10":[121],"min":[122],"without":[123],"being":[124],"recharged.":[125],"More":[126],"60":[128],"cm":[129,151],"distance":[131],"any":[133],"practically":[134],"relevant":[135],"direction":[136],"be":[138],"covered":[139],"by":[140],"BLE":[142],"transmission":[144],"if":[145],"implant":[147,157],"placed":[149],"deep":[152],"phantom.":[155],"dimensions":[158],"20":[160],"mm":[161,164],"x":[162],"16":[163],"still":[165],"fit":[166],"on":[167],"bones.":[172]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
