{"id":"https://openalex.org/W4200349923","doi":"https://doi.org/10.1109/biocas49922.2021.9644942","title":"Continuous Wave Dental Doppler Ultrasound System for Measuring Pulp Blood Flow","display_name":"Continuous Wave Dental Doppler Ultrasound System for Measuring Pulp Blood Flow","publication_year":2021,"publication_date":"2021-10-07","ids":{"openalex":"https://openalex.org/W4200349923","doi":"https://doi.org/10.1109/biocas49922.2021.9644942"},"language":"en","primary_location":{"id":"doi:10.1109/biocas49922.2021.9644942","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9644942","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081395089","display_name":"Jaebum Park","orcid":"https://orcid.org/0000-0002-9108-4558"},"institutions":[{"id":"https://openalex.org/I148751991","display_name":"Sogang University","ror":"https://ror.org/056tn4839","country_code":"KR","type":"education","lineage":["https://openalex.org/I148751991"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jaebum Park","raw_affiliation_strings":["Sogang University,Dept. of Electronic Engineering,Seoul,Republic of Korea","Sogang University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sogang University,Dept. of Electronic Engineering,Seoul,Republic of Korea","institution_ids":["https://openalex.org/I148751991"]},{"raw_affiliation_string":"Sogang University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I148751991"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101885403","display_name":"Yeong\u2010Dae Kim","orcid":"https://orcid.org/0000-0003-4783-6430"},"institutions":[{"id":"https://openalex.org/I2250650973","display_name":"Samsung (South Korea)","ror":"https://ror.org/04w3jy968","country_code":"KR","type":"company","lineage":["https://openalex.org/I2250650973"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Yeongdae Kim","raw_affiliation_strings":["Samsung Electronics Device Solutions,Hwaseong,Republic of Korea","Samsung Electronics Device Solutions, Hwaseong, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Samsung Electronics Device Solutions,Hwaseong,Republic of Korea","institution_ids":["https://openalex.org/I2250650973"]},{"raw_affiliation_string":"Samsung Electronics Device Solutions, Hwaseong, Republic of Korea","institution_ids":["https://openalex.org/I2250650973"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076909360","display_name":"Junyeon Kim","orcid":"https://orcid.org/0000-0001-5460-1432"},"institutions":[{"id":"https://openalex.org/I2250650973","display_name":"Samsung (South Korea)","ror":"https://ror.org/04w3jy968","country_code":"KR","type":"company","lineage":["https://openalex.org/I2250650973"]},{"id":"https://openalex.org/I2802194831","display_name":"Samsung Medical Center","ror":"https://ror.org/05a15z872","country_code":"KR","type":"healthcare","lineage":["https://openalex.org/I2250650973","https://openalex.org/I2802194831"]},{"id":"https://openalex.org/I4387155557","display_name":"Samsung Medison (South Korea)","ror":"https://ror.org/05k6h9r09","country_code":null,"type":"company","lineage":["https://openalex.org/I2250650973","https://openalex.org/I4387155557"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Junyeon Kim","raw_affiliation_strings":["Samsung Medison,Seoul,Republic of Korea","Samsung Medison, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Samsung Medison,Seoul,Republic of Korea","institution_ids":["https://openalex.org/I2802194831","https://openalex.org/I2250650973"]},{"raw_affiliation_string":"Samsung Medison, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I2250650973","https://openalex.org/I4387155557"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008072590","display_name":"Tai\u2010Kyong Song","orcid":"https://orcid.org/0000-0002-1530-4002"},"institutions":[{"id":"https://openalex.org/I148751991","display_name":"Sogang University","ror":"https://ror.org/056tn4839","country_code":"KR","type":"education","lineage":["https://openalex.org/I148751991"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Tai-Kyong Song","raw_affiliation_strings":["Sogang University,Dept. of Electronic Engineering,Seoul,Republic of Korea","Sogang University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sogang University,Dept. of Electronic Engineering,Seoul,Republic of Korea","institution_ids":["https://openalex.org/I148751991"]},{"raw_affiliation_string":"Sogang University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I148751991"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.44254788,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10727","display_name":"Ultrasound Imaging and Elastography","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5799576044082642},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5713574290275574},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.4563515782356262},{"id":"https://openalex.org/keywords/spectrogram","display_name":"Spectrogram","score":0.43908393383026123},{"id":"https://openalex.org/keywords/doppler-effect","display_name":"Doppler effect","score":0.43331700563430786},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3258996605873108},{"id":"https://openalex.org/keywords/speech-recognition","display_name":"Speech recognition","score":0.23642343282699585},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22748056054115295},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15110260248184204}],"concepts":[{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5799576044082642},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5713574290275574},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.4563515782356262},{"id":"https://openalex.org/C45273575","wikidata":"https://www.wikidata.org/wiki/Q578970","display_name":"Spectrogram","level":2,"score":0.43908393383026123},{"id":"https://openalex.org/C142757262","wikidata":"https://www.wikidata.org/wiki/Q76436","display_name":"Doppler effect","level":2,"score":0.43331700563430786},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3258996605873108},{"id":"https://openalex.org/C28490314","wikidata":"https://www.wikidata.org/wiki/Q189436","display_name":"Speech recognition","level":1,"score":0.23642343282699585},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22748056054115295},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15110260248184204},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/biocas49922.2021.9644942","is_oa":false,"landing_page_url":"https://doi.org/10.1109/biocas49922.2021.9644942","pdf_url":null,"source":{"id":"https://openalex.org/S4363608526","display_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1997291294","https://openalex.org/W2013579375","https://openalex.org/W2092731838","https://openalex.org/W2094364596","https://openalex.org/W2129884298","https://openalex.org/W2151210471","https://openalex.org/W2517090683","https://openalex.org/W2529283716","https://openalex.org/W2794406787"],"related_works":["https://openalex.org/W2530685530","https://openalex.org/W4375868962","https://openalex.org/W2011227383","https://openalex.org/W2088854863","https://openalex.org/W1976719989","https://openalex.org/W2380594826","https://openalex.org/W2031629218","https://openalex.org/W4238525810","https://openalex.org/W4247875078","https://openalex.org/W4238161731"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3],"present":[4],"a":[5,29,46,50,63],"continuous":[6],"wave":[7],"dental":[8,38],"Doppler":[9,139],"ultrasound":[10],"system":[11,67],"(DDUS),":[12],"in":[13,25,35,146],"which":[14],"22-MHz":[15],"ultrasonic":[16,74],"probes":[17],"are":[18,136,144],"utilized.":[19],"It":[20],"is":[21,126],"an":[22],"optimized":[23],"efficacy":[24],"terms":[26],"of":[27,37,45],"monitoring":[28],"slow":[30],"pulp":[31],"blood":[32],"flow":[33],"(PBF)":[34],"point":[36],"diagnostic":[39],"applications.":[40],"The":[41,65,93,134],"proposed":[42],"DDUS":[43,151],"consists":[44],"dual":[47],"elements":[48],"transducer,":[49],"two-channel":[51],"(one":[52],"for":[53,58],"transmission":[54,75],"and":[55,62,76,89,110,141,143],"the":[56,96,118,122,149],"other":[57,97],"reception)":[59],"probe":[60,66],"system,":[61],"laptop.":[64],"performs":[68,73,99],"analog":[69],"front-end":[70],"processing":[71,101],"that":[72],"reception,":[77],"low":[78,85],"noise":[79],"amplification":[80],"(LNA),":[81],"quadrature":[82],"demodulation":[83],"(QDM),":[84],"pass":[86],"filtering":[87],"(LPF),":[88],"analog-to-digital":[90],"conversion":[91],"(ADC).":[92],"laptop,":[94],"on":[95],"hand,":[98],"mid/back-end":[100],"such":[102],"as":[103,138],"decimation,":[104],"log":[105],"compression,":[106],"clutter":[107,123],"filtering/noise":[108,124],"reduction,":[109],"data":[111],"analysis":[112],"represented":[113],"by":[114,128],"spectrum/spectrogram.":[115],"To":[116],"increase":[117],"signal-to-noise":[119],"ratio":[120],"(SNR),":[121],"reduction":[125],"implemented":[127],"Hankel":[129],"singular":[130],"value":[131],"decomposition":[132],"(SVD).":[133],"results":[135],"displayed":[137],"spectrum":[140],"spectrogram":[142],"provided":[145],"real-time":[147],"via":[148],"developed":[150],"customized":[152],"graphical":[153],"user":[154],"interface":[155],"(GUI).":[156]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
