{"id":"https://openalex.org/W2342493124","doi":"https://doi.org/10.1109/bhi.2016.7455866","title":"Estimation of wrist flexion angle from muscle thickness changes measured by a flexible ultrasonic sensor","display_name":"Estimation of wrist flexion angle from muscle thickness changes measured by a flexible ultrasonic sensor","publication_year":2016,"publication_date":"2016-02-01","ids":{"openalex":"https://openalex.org/W2342493124","doi":"https://doi.org/10.1109/bhi.2016.7455866","mag":"2342493124"},"language":"en","primary_location":{"id":"doi:10.1109/bhi.2016.7455866","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bhi.2016.7455866","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055353146","display_name":"Andy C. Huang","orcid":"https://orcid.org/0000-0002-4155-7935"},"institutions":[{"id":"https://openalex.org/I67031392","display_name":"Carleton University","ror":"https://ror.org/02qtvee93","country_code":"CA","type":"education","lineage":["https://openalex.org/I67031392"]}],"countries":["CA"],"is_corresponding":true,"raw_author_name":"Andy Huang","raw_affiliation_strings":["Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada"],"affiliations":[{"raw_affiliation_string":"Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada","institution_ids":["https://openalex.org/I67031392"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022444118","display_name":"Yuu Ono","orcid":"https://orcid.org/0000-0002-7559-5227"},"institutions":[{"id":"https://openalex.org/I67031392","display_name":"Carleton University","ror":"https://ror.org/02qtvee93","country_code":"CA","type":"education","lineage":["https://openalex.org/I67031392"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Yuu Ono","raw_affiliation_strings":["Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada"],"affiliations":[{"raw_affiliation_string":"Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada","institution_ids":["https://openalex.org/I67031392"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5055353146"],"corresponding_institution_ids":["https://openalex.org/I67031392"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.03221451,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"188","last_page":"191"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.9919999837875366,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wrist","display_name":"Wrist","score":0.8073973655700684},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.7622561454772949},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5437511205673218},{"id":"https://openalex.org/keywords/range-of-motion","display_name":"Range of motion","score":0.5134316682815552},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.47877538204193115},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.45328831672668457},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4065614640712738},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3088186979293823},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.20707690715789795},{"id":"https://openalex.org/keywords/anatomy","display_name":"Anatomy","score":0.20257410407066345},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.09771639108657837},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0764976441860199}],"concepts":[{"id":"https://openalex.org/C2778216619","wikidata":"https://www.wikidata.org/wiki/Q185706","display_name":"Wrist","level":2,"score":0.8073973655700684},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.7622561454772949},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5437511205673218},{"id":"https://openalex.org/C60465272","wikidata":"https://www.wikidata.org/wiki/Q494478","display_name":"Range of motion","level":2,"score":0.5134316682815552},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.47877538204193115},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.45328831672668457},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4065614640712738},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3088186979293823},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20707690715789795},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.20257410407066345},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.09771639108657837},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0764976441860199},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bhi.2016.7455866","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bhi.2016.7455866","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.41999998688697815,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1549114171","https://openalex.org/W1897459461","https://openalex.org/W1993864903","https://openalex.org/W2004783820","https://openalex.org/W2043668245","https://openalex.org/W2054320984","https://openalex.org/W2079200476","https://openalex.org/W2081830812","https://openalex.org/W2091948170","https://openalex.org/W2094535376","https://openalex.org/W2104674756","https://openalex.org/W2138570327","https://openalex.org/W2158951777","https://openalex.org/W2165429518","https://openalex.org/W6632872799","https://openalex.org/W6639477878"],"related_works":["https://openalex.org/W2406926056","https://openalex.org/W2170071336","https://openalex.org/W110334421","https://openalex.org/W2048493693","https://openalex.org/W2013246180","https://openalex.org/W2062145478","https://openalex.org/W2139687886","https://openalex.org/W2044891495","https://openalex.org/W2100326899","https://openalex.org/W2884402489"],"abstract_inverted_index":{"The":[0,104],"estimation":[1,100],"of":[2,11,45,49,70,94,101,129],"joint":[3],"motion":[4,47,132],"from":[5,29,108],"muscle":[6,17,38,73,110],"thickness":[7,69,111],"has":[8],"a":[9,30,42,82],"variety":[10],"applications,":[12],"such":[13],"as":[14],"gait":[15],"analysis,":[16],"disease":[18],"diagnosis,":[19],"and":[20,77],"prosthesis":[21],"control.":[22],"A":[23,58],"wearable":[24],"flexible":[25,96,116],"ultrasonic":[26,56,97,117],"sensor":[27,98,118],"made":[28],"piezoelectric":[31],"polymer":[32],"film":[33],"is":[34,62,88],"able":[35],"to":[36,53,64,90],"monitor":[37],"activities":[39],"while":[40],"allowing":[41],"wider":[43],"range":[44],"body":[46],"because":[48],"its":[50],"lightweight":[51],"compared":[52],"conventional":[54],"medical":[55],"probes.":[57],"bone-muscle":[59],"lever":[60],"model":[61],"employed":[63],"obtain":[65],"the":[66,71,75,92,95,109,115,130,135],"relationship":[67,87],"between":[68],"flexor":[72],"at":[74],"forearm":[76],"wrist":[78,102,105,131],"flexion":[79],"angle":[80],"with":[81,122],"healthy":[83],"male":[84],"subject.":[85],"This":[86],"applied":[89],"investigate":[91],"application":[93],"for":[99],"motion.":[103],"angles":[106],"estimated":[107],"changes":[112],"measured":[113],"by":[114,125],"exhibit":[119],"similar":[120],"trend":[121],"those":[123],"obtained":[124],"video":[126],"image":[127],"analysis":[128],"captured":[133],"during":[134],"experiment.":[136]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2}],"updated_date":"2025-11-25T21:42:39.735039","created_date":"2025-10-10T00:00:00"}
