{"id":"https://openalex.org/W2006681111","doi":"https://doi.org/10.1109/bhi.2012.6211608","title":"A novel method to estimate baroreflex sensitivity based on pulse transit time","display_name":"A novel method to estimate baroreflex sensitivity based on pulse transit time","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2006681111","doi":"https://doi.org/10.1109/bhi.2012.6211608","mag":"2006681111"},"language":"en","primary_location":{"id":"doi:10.1109/bhi.2012.6211608","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bhi.2012.6211608","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100345243","display_name":"Qing Liu","orcid":"https://orcid.org/0000-0003-1825-6760"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Qing Liu","raw_affiliation_strings":["Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107915221","display_name":"Carmen","orcid":null},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Carmen","raw_affiliation_strings":["Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015802672","display_name":"Carmen C. Y. Poon","orcid":"https://orcid.org/0000-0001-7717-4752"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"C. Y. Poon","raw_affiliation_strings":["Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5070333614","display_name":"Yuan\u2010Ting Zhang","orcid":"https://orcid.org/0000-0003-4150-5470"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]},{"id":"https://openalex.org/I19820366","display_name":"Chinese Academy of Sciences","ror":"https://ror.org/034t30j35","country_code":"CN","type":"government","lineage":["https://openalex.org/I19820366"]},{"id":"https://openalex.org/I4210145761","display_name":"Shenzhen Institutes of Advanced Technology","ror":"https://ror.org/04gh4er46","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210145761"]}],"countries":["CN","HK"],"is_corresponding":false,"raw_author_name":"Yuan-ting Zhang","raw_affiliation_strings":["Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China","SlAT Institute of Biomedical and Health Engineering, Key Laboratory for Health Informatics, Chinese Academy of Sciences, Shenzhen, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, Chinese University of Hong Kong, Sha Tin, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]},{"raw_affiliation_string":"SlAT Institute of Biomedical and Health Engineering, Key Laboratory for Health Informatics, Chinese Academy of Sciences, Shenzhen, China","institution_ids":["https://openalex.org/I19820366","https://openalex.org/I4210145761"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.6085,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.79889299,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"135","issue":null,"first_page":"432","last_page":"434"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11373","display_name":"Sleep and Work-Related Fatigue","score":0.989799976348877,"subfield":{"id":"https://openalex.org/subfields/3205","display_name":"Experimental and Cognitive Psychology"},"field":{"id":"https://openalex.org/fields/32","display_name":"Psychology"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.8332885503768921},{"id":"https://openalex.org/keywords/baroreflex","display_name":"Baroreflex","score":0.8243361711502075},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.6247698664665222},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.4725111424922943},{"id":"https://openalex.org/keywords/beat","display_name":"Beat (acoustics)","score":0.454184889793396},{"id":"https://openalex.org/keywords/correlation-coefficient","display_name":"Correlation coefficient","score":0.4354342222213745},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.4181019067764282},{"id":"https://openalex.org/keywords/plethysmograph","display_name":"Plethysmograph","score":0.4128248691558838},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.3895689845085144},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.35958266258239746},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.35675299167633057},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.3027501106262207},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.2537275552749634},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.1942896842956543},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18592843413352966},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.1651175320148468},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.08385542035102844}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8332885503768921},{"id":"https://openalex.org/C191237925","wikidata":"https://www.wikidata.org/wiki/Q808725","display_name":"Baroreflex","level":4,"score":0.8243361711502075},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.6247698664665222},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.4725111424922943},{"id":"https://openalex.org/C189809214","wikidata":"https://www.wikidata.org/wiki/Q829522","display_name":"Beat (acoustics)","level":2,"score":0.454184889793396},{"id":"https://openalex.org/C2780092901","wikidata":"https://www.wikidata.org/wiki/Q3433612","display_name":"Correlation coefficient","level":2,"score":0.4354342222213745},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.4181019067764282},{"id":"https://openalex.org/C73362275","wikidata":"https://www.wikidata.org/wiki/Q181277","display_name":"Plethysmograph","level":2,"score":0.4128248691558838},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3895689845085144},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.35958266258239746},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.35675299167633057},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.3027501106262207},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2537275552749634},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.1942896842956543},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18592843413352966},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.1651175320148468},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.08385542035102844},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bhi.2012.6211608","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bhi.2012.6211608","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation","score":0.4099999964237213}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W14301604","https://openalex.org/W2005383756","https://openalex.org/W2046613407","https://openalex.org/W2056667098","https://openalex.org/W2059208589","https://openalex.org/W2071686905","https://openalex.org/W2082902770","https://openalex.org/W2096073349","https://openalex.org/W2103568459","https://openalex.org/W2140104458","https://openalex.org/W2163008375","https://openalex.org/W2167925220","https://openalex.org/W2310449702","https://openalex.org/W6698561409"],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W4297152434","https://openalex.org/W2072858761","https://openalex.org/W1540261775","https://openalex.org/W4200107443","https://openalex.org/W4239033438","https://openalex.org/W2414028099","https://openalex.org/W2414250197","https://openalex.org/W4391315191"],"abstract_inverted_index":{"Baroreflex":[0],"sensitivity":[1],"(BRS)":[2],"has":[3],"emerged":[4],"as":[5],"a":[6,68],"prognostic":[7],"factor":[8],"in":[9,22,65,132],"cardiology.":[10],"Spontaneous":[11],"sequence":[12,79],"technique":[13,26,80],"is":[14,45],"one":[15],"of":[16,101,112],"the":[17,78],"most":[18],"commonly":[19],"used":[20],"methods":[21,151],"measuring":[23],"BRS.":[24],"The":[25,84,122],"requires":[27],"continuous":[28,94],"beat-to-beat":[29],"blood":[30],"pressure":[31],"(BP)":[32],"which,":[33],"however,":[34],"cannot":[35],"be":[36,52],"obtained":[37,104],"conveniently.":[38],"Considering":[39],"that":[40,71,153],"pulse":[41],"transit":[42],"time":[43],"(PTT)":[44],"inversely":[46],"related":[47],"to":[48],"BP":[49],"and":[50,54,60,97,107,116,139,143],"can":[51],"easily":[53],"continuously":[55],"acquired":[56],"from":[57,74,92,149],"electrocardiogram":[58],"(ECG)":[59],"photoplethysmogram":[61],"(PPG),":[62],"we":[63],"proposed":[64],"this":[66],"study":[67],"novel":[69],"method":[70],"estimates":[72,131],"BRS":[73,115,118,130,154],"PTT":[75,96],"based":[76],"on":[77,88],"with":[81],"low-pass":[82],"filtering.":[83],"experiment":[85],"was":[86],"conducted":[87],"25":[89],"healthy":[90],"subjects":[91],"whom":[93],"BP,":[95],"R-R":[98],"interval":[99],"(RRI)":[100],"ECG":[102],"were":[103,119],"before,":[105,141],"during":[106,142],"after":[108,144,158],"drinking":[109,145],"400":[110],"ml":[111],"water.":[113],"SBP-based":[114],"PTT-based":[117],"separately":[120],"calculated.":[121],"results":[123,148],"showed":[124],"high":[125],"correlations":[126],"between":[127],"these":[128],"two":[129],"all":[133],"situations":[134],"(correlation":[135],"coefficient":[136],"\u03b3=0.90,":[137],"0.70":[138],"0.81":[140],"respectively).":[146],"Furthermore,":[147],"both":[150],"indicate":[152],"increased":[155],"significantly":[156],"(p<;0.01)":[157],"water":[159],"drinking.":[160]},"counts_by_year":[{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
