{"id":"https://openalex.org/W2540500390","doi":"https://doi.org/10.1109/asscc.2012.6523306","title":"Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer","display_name":"Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer","publication_year":2012,"publication_date":"2012-11-01","ids":{"openalex":"https://openalex.org/W2540500390","doi":"https://doi.org/10.1109/asscc.2012.6523306","mag":"2540500390"},"language":"en","primary_location":{"id":"doi:10.1109/asscc.2012.6523306","is_oa":false,"landing_page_url":"https://doi.org/10.1109/asscc.2012.6523306","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 10th International Power &amp; Energy Conference (IPEC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056194955","display_name":"Mai Tuan Dat","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Mai Tuan Dat","raw_affiliation_strings":["K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075151778","display_name":"Thomas Wijnhoven","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Thomas Wijnhoven","raw_affiliation_strings":["K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027002529","display_name":"Johan Driesen","orcid":"https://orcid.org/0000-0002-1025-0949"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Johan Driesen","raw_affiliation_strings":["K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"K.U. Leuven, ESAT - ELECTA, Kasteelpark Arenberg 10, bus 2445, 3001 HEVERLEE, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I99464096"],"apc_list":null,"apc_paid":null,"fwci":1.2277,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.82594303,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.6706265807151794},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.6302629709243774},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6184870004653931},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.6105303168296814},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.5949206352233887},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5508855581283569},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.5467660427093506},{"id":"https://openalex.org/keywords/power-electronics","display_name":"Power electronics","score":0.5269770622253418},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.5141299366950989},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.46524015069007874},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.46217814087867737},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44960856437683105},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42579829692840576},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4136376678943634},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.41051530838012695},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.1760438084602356},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.09704962372779846},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.05812329053878784}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6706265807151794},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.6302629709243774},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6184870004653931},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.6105303168296814},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.5949206352233887},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5508855581283569},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.5467660427093506},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.5269770622253418},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.5141299366950989},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.46524015069007874},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.46217814087867737},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44960856437683105},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42579829692840576},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4136376678943634},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.41051530838012695},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.1760438084602356},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.09704962372779846},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.05812329053878784},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/asscc.2012.6523306","is_oa":false,"landing_page_url":"https://doi.org/10.1109/asscc.2012.6523306","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 10th International Power &amp; Energy Conference (IPEC)","raw_type":"proceedings-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/400143","is_oa":false,"landing_page_url":"https://lirias.kuleuven.be/bitstream/123456789/400143/1/Th23.4-P0199.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"10th International Power and Energy Conference (IPEC 2012), Hochiminh city, Vietnam, 12-13 December 2012","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.7900000214576721,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320324551","display_name":"Vlaamse Instelling voor Technologisch Onderzoek","ror":"https://ror.org/04gq0w522"},{"id":"https://openalex.org/F4320327336","display_name":"Vlaamse regering","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W2003549893","https://openalex.org/W2024724842","https://openalex.org/W2106482668","https://openalex.org/W2141628413","https://openalex.org/W2156966236","https://openalex.org/W2161368778","https://openalex.org/W2533932696","https://openalex.org/W6651276447"],"related_works":["https://openalex.org/W2102525122","https://openalex.org/W2153096481","https://openalex.org/W2148616436","https://openalex.org/W4306316843","https://openalex.org/W2036953450","https://openalex.org/W2130594209","https://openalex.org/W2527822502","https://openalex.org/W4245282135","https://openalex.org/W2170004886","https://openalex.org/W4300955944"],"abstract_inverted_index":{"A":[0],"grid-connected":[1,32],"photovoltaic(PV)":[2],"power":[3,9,63,97,102],"plant":[4],"is":[5,42,70],"mainly":[6],"based":[7],"on":[8],"electronics":[10],"equipments":[11],"which":[12],"are":[13],"considered":[14],"as":[15],"the":[16,28,46,54,62,73,88],"most":[17],"vulnerable":[18],"parts":[19],"in":[20,57,72,99],"a":[21,35,39,94],"PV":[22,33,55,68],"system.":[23],"In":[24],"order":[25],"to":[26,44,51,92],"increase":[27],"reliability":[29],"of":[30,48,59,61,96],"modular":[31],"panel,":[34],"solution":[36],"by":[37],"using":[38],"Scott":[40],"transformer":[41],"presented":[43],"reduce":[45],"number":[47],"switches":[49,98],"and":[50,75],"continuously":[52],"operate":[53],"system":[56,90],"case":[58],"switch-failures":[60],"converter.":[64],"The":[65,77],"three-phase":[66],"type":[67],"inverter":[69],"analyzed":[71],"normal":[74],"fault-operation.":[76],"simulation":[78],"has":[79],"shown":[80],"that":[81],"fault":[82],"tolerance":[83],"can":[84],"be":[85],"achieved":[86],"with":[87],"proposed":[89],"configuration":[91],"give":[93],"redundancy":[95],"an":[100],"Integrated":[101],"electronic":[103],"module.":[104]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":4},{"year":2018,"cited_by_count":3},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2}],"updated_date":"2026-07-02T09:51:11.867554","created_date":"2025-10-10T00:00:00"}
