{"id":"https://openalex.org/W3039576817","doi":"https://doi.org/10.1109/aqtr49680.2020.9129963","title":"BOOST converter modelling as a subsystem of a photovoltaic panel control system","display_name":"BOOST converter modelling as a subsystem of a photovoltaic panel control system","publication_year":2020,"publication_date":"2020-05-01","ids":{"openalex":"https://openalex.org/W3039576817","doi":"https://doi.org/10.1109/aqtr49680.2020.9129963","mag":"3039576817"},"language":"en","primary_location":{"id":"doi:10.1109/aqtr49680.2020.9129963","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aqtr49680.2020.9129963","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048052697","display_name":"Mircea \u015etefan Simoiu","orcid":"https://orcid.org/0000-0002-0565-0526"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Mircea Stefan Simoiu","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087914597","display_name":"Vasile Calofir","orcid":"https://orcid.org/0000-0002-9250-9343"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Vasile Calofir","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108621922","display_name":"Sergiu Stelian Iliescu","orcid":null},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Sergiu Stelian Iliescu","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010159159","display_name":"Ioana F\u0103g\u0103r\u0103\u015fan","orcid":"https://orcid.org/0000-0002-0041-6431"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Ioana Fagarasan","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048697620","display_name":"Nicoleta Arghira","orcid":"https://orcid.org/0000-0002-2066-968X"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Nicoleta Arghira","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University Politehnica of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I61641377"],"apc_list":null,"apc_paid":null,"fwci":0.2686,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.48533251,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"42","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9936000108718872,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12309","display_name":"solar cell performance optimization","score":0.9865999817848206,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.6491063237190247},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.551425576210022},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5482127070426941},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5342072248458862},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.4927106201648712},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4840392470359802},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.47981715202331543},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.4636327922344208},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4574955403804779},{"id":"https://openalex.org/keywords/digital-control","display_name":"Digital control","score":0.4501842260360718},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.43390488624572754},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3479931354522705},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34787821769714355},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.23471608757972717},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.21951913833618164}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6491063237190247},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.551425576210022},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5482127070426941},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5342072248458862},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.4927106201648712},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4840392470359802},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.47981715202331543},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4636327922344208},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4574955403804779},{"id":"https://openalex.org/C158411068","wikidata":"https://www.wikidata.org/wiki/Q2720568","display_name":"Digital control","level":2,"score":0.4501842260360718},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.43390488624572754},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3479931354522705},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34787821769714355},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23471608757972717},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.21951913833618164},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/aqtr49680.2020.9129963","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aqtr49680.2020.9129963","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1593238570","https://openalex.org/W2041835064","https://openalex.org/W2103792123","https://openalex.org/W2133119486","https://openalex.org/W2159110945","https://openalex.org/W2230386561","https://openalex.org/W2560164826","https://openalex.org/W2765747220","https://openalex.org/W3160860933","https://openalex.org/W6745285578","https://openalex.org/W6795382015"],"related_works":["https://openalex.org/W2386968573","https://openalex.org/W2395064349","https://openalex.org/W4251298892","https://openalex.org/W2034374297","https://openalex.org/W2356013541","https://openalex.org/W2385444679","https://openalex.org/W3133868776","https://openalex.org/W2392812934","https://openalex.org/W2348289076","https://openalex.org/W2981639619"],"abstract_inverted_index":{"Photovoltaic":[0],"systems":[1],"are":[2,87],"increasingly":[3],"used":[4,33,63],"as":[5,34,120,122],"renewable":[6],"energy":[7],"sources,":[8],"thus":[9],"it":[10],"is":[11,32,71,102],"necessary":[12],"to":[13,19,90],"implement":[14],"control":[15,67,118],"algorithms":[16,26],"that":[17,28,60],"strive":[18],"obtain":[20],"maxim":[21],"power":[22],"output.":[23],"Consequently,":[24],"these":[25],"imply":[27],"a":[29,35,48,52,57,98,143],"DC-DC":[30,53],"converter":[31,55,125],"subsystem":[36,106],"in":[37,64],"controlling":[38],"the":[39,45,74,81,84,94,105,108,113,123,137],"output":[40],"voltage.":[41],"In":[42],"this":[43],"context,":[44],"paper":[46],"proposes":[47],"mathematical":[49],"model":[50,70],"of":[51],"BOOST":[54,124],"for":[56,83,104,142],"PV":[58,95],"panel":[59],"can":[61],"be":[62,91],"designing":[65],"conventional":[66],"algorithms.":[68],"The":[69,117,132],"developed":[72,109],"with":[73,93],"State":[75],"Space":[76],"Averaging":[77],"Method":[78],"and":[79,112,128],"also":[80],"parameters":[82],"electronic":[85],"components":[86],"chosen":[88],"accordingly":[89],"compatible":[92],"module.":[96],"Also,":[97],"digital":[99,133],"PI":[100],"controller":[101,134],"designed":[103],"considering":[107],"linear":[110],"approximation":[111],"voltage":[114,145],"quality":[115,140],"requirements.":[116],"structure,":[119],"well":[121],"were":[126],"modelled":[127],"validated":[129],"using":[130],"Matlab/Simulink.":[131],"performances":[135],"respects":[136],"imposed":[138],"energy/voltage":[139],"limits":[141],"variable":[144],"reference.":[146]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
