{"id":"https://openalex.org/W2485904927","doi":"https://doi.org/10.1109/aqtr.2016.7501330","title":"Voltage \u2014 Reactive power control in renewables power plants: Technical requirements applied in the Romanian power grid","display_name":"Voltage \u2014 Reactive power control in renewables power plants: Technical requirements applied in the Romanian power grid","publication_year":2016,"publication_date":"2016-05-01","ids":{"openalex":"https://openalex.org/W2485904927","doi":"https://doi.org/10.1109/aqtr.2016.7501330","mag":"2485904927"},"language":"en","primary_location":{"id":"doi:10.1109/aqtr.2016.7501330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aqtr.2016.7501330","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015948041","display_name":"Elena-Daniela Dinu","orcid":null},"institutions":[{"id":"https://openalex.org/I2036976","display_name":"Transelectrica (Romania)","ror":"https://ror.org/05fynv140","country_code":"RO","type":"company","lineage":["https://openalex.org/I2036976"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Elena-Daniela Dinu","raw_affiliation_strings":["CNTEE Transelectrica SA-UNO-DEN, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CNTEE Transelectrica SA-UNO-DEN, Bucharest, Romania","institution_ids":["https://openalex.org/I2036976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041453346","display_name":"Doina Ilisiu","orcid":null},"institutions":[{"id":"https://openalex.org/I2036976","display_name":"Transelectrica (Romania)","ror":"https://ror.org/05fynv140","country_code":"RO","type":"company","lineage":["https://openalex.org/I2036976"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Doina Ilisiu","raw_affiliation_strings":["CNTEE Transelectrica SA-UNO-DEN, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CNTEE Transelectrica SA-UNO-DEN, Bucharest, Romania","institution_ids":["https://openalex.org/I2036976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010159159","display_name":"Ioana F\u0103g\u0103r\u0103\u015fan","orcid":"https://orcid.org/0000-0002-0041-6431"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Ioana Fagarasan","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]},{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108621922","display_name":"Sergiu Stelian Iliescu","orcid":null},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Sergiu Stelian Iliescu","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]},{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048697620","display_name":"Nicoleta Arghira","orcid":"https://orcid.org/0000-0002-2066-968X"},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Nicoleta Arghira","raw_affiliation_strings":["Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]},{"raw_affiliation_string":"Department of Automatic Control and Industrial Informatics, University \"Politehnica\" of Bucharest, Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.186,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.5749236,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.6758888959884644},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.6704748868942261},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6109123826026917},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.5739312171936035},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.529964029788971},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.524059534072876},{"id":"https://openalex.org/keywords/base-load-power-plant","display_name":"Base load power plant","score":0.5130704641342163},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.49834609031677246},{"id":"https://openalex.org/keywords/grid-parity","display_name":"Grid parity","score":0.48517900705337524},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.4803139567375183},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.46507856249809265},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.45434898138046265},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4512374699115753},{"id":"https://openalex.org/keywords/stand-alone-power-system","display_name":"Stand-alone power system","score":0.4510204792022705},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.43487563729286194},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4289349913597107},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.37436196208000183},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3429408669471741},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07024681568145752}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6758888959884644},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.6704748868942261},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6109123826026917},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.5739312171936035},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.529964029788971},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.524059534072876},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.5130704641342163},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.49834609031677246},{"id":"https://openalex.org/C186503672","wikidata":"https://www.wikidata.org/wiki/Q761847","display_name":"Grid parity","level":4,"score":0.48517900705337524},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4803139567375183},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.46507856249809265},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.45434898138046265},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4512374699115753},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.4510204792022705},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43487563729286194},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4289349913597107},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37436196208000183},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3429408669471741},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07024681568145752},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/aqtr.2016.7501330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aqtr.2016.7501330","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320323444","display_name":"Autoritatea National\u0103 pentru Cercetare Stiintific\u0103","ror":"https://ror.org/03padf885"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W2015682670","https://openalex.org/W2153011677","https://openalex.org/W2181339399","https://openalex.org/W3119044781","https://openalex.org/W4250261774","https://openalex.org/W6685879942","https://openalex.org/W6788359879"],"related_works":["https://openalex.org/W3023079971","https://openalex.org/W2326695616","https://openalex.org/W4206534921","https://openalex.org/W3022044771","https://openalex.org/W4387899760","https://openalex.org/W830897817","https://openalex.org/W3211132681","https://openalex.org/W2998934060","https://openalex.org/W2912604225","https://openalex.org/W4312782812"],"abstract_inverted_index":{"The":[0,103],"presence":[1],"of":[2,6,70,113],"a":[3,47,68,110],"significant":[4],"proportion":[5],"renewable":[7,22,60],"power":[8,29,34,50,55,61,97,125],"plants":[9,98],"in":[10,46,67],"the":[11,19,44,74,101,114,123],"Romanian":[12],"National":[13,75],"Power":[14],"System":[15,77],"has":[16,38],"led":[17],"to":[18,24,28,100,122],"need":[20],"for":[21,59],"generation":[23],"contribute":[25],"more":[26],"significantly":[27],"system":[30,51],"voltage":[31],"and":[32,40,80],"reactive":[33],"control.":[35],"This":[36],"paper":[37],"theoretical":[39],"practical":[41],"contributions":[42],"on":[43,84,95,109],"operation":[45],"complex,":[48],"interconnected":[49],"through":[52],"secondary":[53],"voltage-reactive":[54],"(U-Q)":[56],"control":[57,105],"requirements":[58],"plants.":[62],"These":[63],"conditions":[64],"are":[65,120],"gathered":[66],"set":[69],"regulations":[71,106],"proposed":[72],"by":[73],"Transport":[76],"Operator":[78],"(TSO)":[79],"were":[81,93,107],"implemented":[82],"successfully":[83],"subsystems":[85],"that":[86],"include":[87],"distributed":[88],"energy":[89],"resources.":[90],"Several":[91],"tests":[92],"done":[94],"wind":[96,117],"connected":[99,121],"grid.":[102,126],"U-Q":[104],"based":[108],"systemic":[111],"approach":[112],"substations":[115],"where":[116],"or":[118],"photovoltaic":[119],"national":[124]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
