{"id":"https://openalex.org/W4415822179","doi":"https://doi.org/10.1109/amps66841.2025.11219911","title":"Dynamic Estimation and Fusion of Frequency and ROCOF Data via Local Gossiping","display_name":"Dynamic Estimation and Fusion of Frequency and ROCOF Data via Local Gossiping","publication_year":2025,"publication_date":"2025-09-24","ids":{"openalex":"https://openalex.org/W4415822179","doi":"https://doi.org/10.1109/amps66841.2025.11219911"},"language":"en","primary_location":{"id":"doi:10.1109/amps66841.2025.11219911","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps66841.2025.11219911","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 15th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008004705","display_name":"Guglielmo Frigo","orcid":"https://orcid.org/0000-0002-5762-4354"},"institutions":[{"id":"https://openalex.org/I4210103407","display_name":"Swiss Federal Institute of Metrology","ror":"https://ror.org/0115xv923","country_code":"CH","type":"government","lineage":["https://openalex.org/I4210103407"]}],"countries":["CH"],"is_corresponding":true,"raw_author_name":"Guglielmo Frigo","raw_affiliation_strings":["METAS &#x2013; Federal Institute of Metrology,Bern-Wabern,Switzerland"],"affiliations":[{"raw_affiliation_string":"METAS &#x2013; Federal Institute of Metrology,Bern-Wabern,Switzerland","institution_ids":["https://openalex.org/I4210103407"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015955356","display_name":"David Macii","orcid":"https://orcid.org/0000-0001-7736-5188"},"institutions":[{"id":"https://openalex.org/I193223587","display_name":"University of Trento","ror":"https://ror.org/05trd4x28","country_code":"IT","type":"education","lineage":["https://openalex.org/I193223587"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"David Macii","raw_affiliation_strings":["University of Trento,Trento,Italy"],"affiliations":[{"raw_affiliation_string":"University of Trento,Trento,Italy","institution_ids":["https://openalex.org/I193223587"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064526108","display_name":"Dario Petri","orcid":"https://orcid.org/0000-0002-9739-4469"},"institutions":[{"id":"https://openalex.org/I193223587","display_name":"University of Trento","ror":"https://ror.org/05trd4x28","country_code":"IT","type":"education","lineage":["https://openalex.org/I193223587"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Dario Petri","raw_affiliation_strings":["University of Trento,Trento,Italy"],"affiliations":[{"raw_affiliation_string":"University of Trento,Trento,Italy","institution_ids":["https://openalex.org/I193223587"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5008004705"],"corresponding_institution_ids":["https://openalex.org/I4210103407"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.32795832,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9487000107765198,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9487000107765198,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.011800000444054604,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.007000000216066837,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.616599977016449},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5932999849319458},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5501999855041504},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4788999855518341},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.478300005197525},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.47540000081062317},{"id":"https://openalex.org/keywords/phasor-measurement-unit","display_name":"Phasor measurement unit","score":0.4740999937057495},{"id":"https://openalex.org/keywords/consistency","display_name":"Consistency (knowledge bases)","score":0.4699999988079071},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.4050999879837036}],"concepts":[{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.616599977016449},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5932999849319458},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5501999855041504},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47940000891685486},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4788999855518341},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.478300005197525},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.47540000081062317},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.4740999937057495},{"id":"https://openalex.org/C2776436953","wikidata":"https://www.wikidata.org/wiki/Q5163215","display_name":"Consistency (knowledge bases)","level":2,"score":0.4699999988079071},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.4050999879837036},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.4047999978065491},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.3765000104904175},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37369999289512634},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.36329999566078186},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.36320000886917114},{"id":"https://openalex.org/C2779662365","wikidata":"https://www.wikidata.org/wiki/Q5416694","display_name":"Event (particle physics)","level":2,"score":0.3082999885082245},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3052000105381012},{"id":"https://openalex.org/C2779853468","wikidata":"https://www.wikidata.org/wiki/Q7662139","display_name":"Synchronism","level":3,"score":0.30379998683929443},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30140000581741333},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.29600000381469727},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.2840000092983246},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.2741999924182892},{"id":"https://openalex.org/C45374587","wikidata":"https://www.wikidata.org/wiki/Q12525525","display_name":"Computation","level":2,"score":0.2678999900817871},{"id":"https://openalex.org/C75778745","wikidata":"https://www.wikidata.org/wiki/Q342626","display_name":"Lag","level":2,"score":0.2554999887943268},{"id":"https://openalex.org/C102248274","wikidata":"https://www.wikidata.org/wiki/Q168388","display_name":"Adaptive filter","level":2,"score":0.2547000050544739}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/amps66841.2025.11219911","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps66841.2025.11219911","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 15th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.unitn.it:11572/481090","is_oa":false,"landing_page_url":"https://hdl.handle.net/11572/481090","pdf_url":null,"source":{"id":"https://openalex.org/S4377196320","display_name":"Iris (University of Trento)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I193223587","host_organization_name":"University of Trento","host_organization_lineage":["https://openalex.org/I193223587"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1899801606","https://openalex.org/W1965041626","https://openalex.org/W2001988223","https://openalex.org/W2010318438","https://openalex.org/W2094843274","https://openalex.org/W2097331455","https://openalex.org/W2791735308","https://openalex.org/W2890316071","https://openalex.org/W2912753047","https://openalex.org/W2929068715","https://openalex.org/W2964428520","https://openalex.org/W3048465714","https://openalex.org/W3053385415","https://openalex.org/W3211924836","https://openalex.org/W4385621222","https://openalex.org/W4400113432","https://openalex.org/W4400114930","https://openalex.org/W4409077033"],"related_works":[],"abstract_inverted_index":{"Phasor":[0],"Measurement":[1],"Units":[2],"(PMUs)":[3],"constitute":[4],"the":[5,51,54,79,105,108,114,131,145,155,167,189],"backbone":[6],"of":[7,19,21,24],"many":[8],"monitoring":[9],"and":[10,17,113,119,127,178],"control":[11,47],"applications":[12],"in":[13,130,198],"power":[14],"systems.":[15],"Frequency":[16,22],"Rate":[18],"Change":[20],"(ROCOF)":[23],"ac":[25],"voltage":[26],"waveforms":[27],"are":[28,37,149],"closely":[29],"related":[30],"to":[31,42,110,116,166,175],"system":[32,193],"stability.":[33],"Therefore,":[34],"these":[35],"parameters":[36],"commonly":[38],"monitored":[39],"by":[40,91,154],"PMUs":[41,156],"trigger":[43],"appropriate":[44],"protection":[45],"or":[46,53],"actions":[48],"when":[49,139],"either":[50],"frequency":[52,115,126],"ROCOF":[55,109,128],"values":[56,81,148],"exceed":[57],"predefined":[58],"critical":[59],"thresholds.":[60],"However,":[61],"previous":[62],"studies":[63],"revealed":[64],"that":[65],"PMU":[66,125,147],"measurement":[67],"uncertainty,":[68],"particularly":[69],"for":[70],"ROCOF,":[71],"drastically":[72],"grows":[73],"during":[74],"fast":[75],"transient":[76],"events,":[77],"making":[78],"reported":[80],"less":[82],"reliable.":[83],"In":[84,134],"this":[85,87],"paper,":[86],"problem":[88],"is":[89,143,173,184],"mitigated":[90],"an":[92,163,199],"Adaptive":[93],"Kalman":[94],"Filter":[95],"(AKF),":[96],"potentially":[97],"running":[98],"on":[99,123],"each":[100],"node.":[101],"Under":[102],"stationary":[103],"conditions":[104,136],"AKF":[106],"assumes":[107],"be":[111,117],"zero":[112],"constant":[118],"it":[120],"relies":[121],"solely":[122],"local":[124,146],"data":[129],"update":[132],"step.":[133],"nonstationary":[135],"instead":[137],"(i.e.,":[138],"some":[140],"anomalous":[141],"event":[142],"detected)":[144],"merged":[150],"with":[151],"those":[152],"\u201cgossiped\u201d":[153],"installed":[157],"at":[158],"adjacent":[159],"nodes":[160],"used":[161],"as":[162,194],"additional":[164],"input":[165],"model.":[168],"A":[169],"basic":[170],"consistency":[171],"check":[172],"performed":[174],"filter":[176],"possible":[177],"bad":[179],"data.":[180],"The":[181],"algorithm":[182],"performance":[183],"analyzed":[185],"through":[186],"simulations":[187],"using":[188],"IEEE":[190],"5-bus":[191],"test":[192],"a":[195],"case":[196],"study":[197],"Under-Frequency":[200],"Load":[201],"Shedding":[202],"(UFLS)":[203],"recovery":[204],"scenario.":[205]},"counts_by_year":[],"updated_date":"2026-03-22T08:09:32.410652","created_date":"2025-11-03T00:00:00"}
