{"id":"https://openalex.org/W4388115984","doi":"https://doi.org/10.1109/amps59207.2023.10297270","title":"Cloud-Based PMUs for Real-Time Power System Monitoring: Theoretical and Experimental Analysis","display_name":"Cloud-Based PMUs for Real-Time Power System Monitoring: Theoretical and Experimental Analysis","publication_year":2023,"publication_date":"2023-09-27","ids":{"openalex":"https://openalex.org/W4388115984","doi":"https://doi.org/10.1109/amps59207.2023.10297270"},"language":"en","primary_location":{"id":"doi:10.1109/amps59207.2023.10297270","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297270","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hdl.handle.net/11585/950393","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075181685","display_name":"Chemseddine Allioua","orcid":null},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Chemseddine Allioua","raw_affiliation_strings":["Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012455420","display_name":"Alessandro Mingotti","orcid":"https://orcid.org/0000-0002-1739-1277"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alessandro Mingotti","raw_affiliation_strings":["Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088604112","display_name":"Roberto Tinarelli","orcid":"https://orcid.org/0000-0002-5377-2421"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Tinarelli","raw_affiliation_strings":["Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018213030","display_name":"Lorenzo Peretto","orcid":"https://orcid.org/0000-0003-3407-2056"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Lorenzo Peretto","raw_affiliation_strings":["Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic, and Information Engineering Alma Mater Studiorum - University of Bologna,Department of Electrical,Bologna,Italy,40136","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008004705","display_name":"Guglielmo Frigo","orcid":"https://orcid.org/0000-0002-5762-4354"},"institutions":[{"id":"https://openalex.org/I4210103407","display_name":"Swiss Federal Institute of Metrology","ror":"https://ror.org/0115xv923","country_code":"CH","type":"government","lineage":["https://openalex.org/I4210103407"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Guglielmo Frigo","raw_affiliation_strings":["Federal Institute of Metrology (METAS),Lindenweg,Wabern, Bern,Switzerland,503084"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal Institute of Metrology (METAS),Lindenweg,Wabern, Bern,Switzerland,503084","institution_ids":["https://openalex.org/I4210103407"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"01","last_page":"06"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cloud-computing","display_name":"Cloud computing","score":0.8817414045333862},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.7227729558944702},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6838783621788025},{"id":"https://openalex.org/keywords/synchronizing","display_name":"Synchronizing","score":0.6092215776443481},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.5692552924156189},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5496280789375305},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.5089175701141357},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.4827558398246765},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.4341859817504883},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.39465177059173584},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.35246774554252625},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.32969874143600464},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.2331697940826416},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.22818154096603394},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22176799178123474},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.19885268807411194},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.17975065112113953},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.09982296824455261}],"concepts":[{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.8817414045333862},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.7227729558944702},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6838783621788025},{"id":"https://openalex.org/C162932704","wikidata":"https://www.wikidata.org/wiki/Q1058791","display_name":"Synchronizing","level":3,"score":0.6092215776443481},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.5692552924156189},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5496280789375305},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.5089175701141357},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.4827558398246765},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.4341859817504883},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.39465177059173584},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.35246774554252625},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.32969874143600464},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.2331697940826416},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.22818154096603394},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22176799178123474},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.19885268807411194},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.17975065112113953},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.09982296824455261},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/amps59207.2023.10297270","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297270","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},{"id":"pmh:oai:cris.unibo.it:11585/950393","is_oa":true,"landing_page_url":"https://hdl.handle.net/11585/950393","pdf_url":null,"source":{"id":"https://openalex.org/S4306402579","display_name":"Archivio istituzionale della ricerca (Alma Mater Studiorum Universit\u00e0 di Bologna)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210117483","host_organization_name":"Istituto di Ematologia di Bologna","host_organization_lineage":["https://openalex.org/I4210117483"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:cris.unibo.it:11585/950393","is_oa":true,"landing_page_url":"https://hdl.handle.net/11585/950393","pdf_url":null,"source":{"id":"https://openalex.org/S4306402579","display_name":"Archivio istituzionale della ricerca (Alma Mater Studiorum Universit\u00e0 di Bologna)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210117483","host_organization_name":"Istituto di Ematologia di Bologna","host_organization_lineage":["https://openalex.org/I4210117483"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"score":0.6399999856948853,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1540901973","https://openalex.org/W2048401814","https://openalex.org/W2539311169","https://openalex.org/W2588068866","https://openalex.org/W2594574246","https://openalex.org/W2766203650","https://openalex.org/W2777422892","https://openalex.org/W2810867055","https://openalex.org/W2993247916","https://openalex.org/W3034416865","https://openalex.org/W3200069532","https://openalex.org/W4210730809","https://openalex.org/W4285128214","https://openalex.org/W4289940226","https://openalex.org/W4312686551","https://openalex.org/W4312879724"],"related_works":["https://openalex.org/W2182509182","https://openalex.org/W2125787228","https://openalex.org/W2138143921","https://openalex.org/W2102647849","https://openalex.org/W1923806246","https://openalex.org/W2547260311","https://openalex.org/W2054057392","https://openalex.org/W2162956301","https://openalex.org/W2180313337","https://openalex.org/W3016586339"],"abstract_inverted_index":{"The":[0,118,167,177],"emergence":[1],"of":[2,45,55,88,120,129,184,190],"modern":[3],"cloud":[4,149],"computing":[5],"has":[6,51,153],"brought":[7],"a":[8,48,98,126,136,181],"revolution":[9],"in":[10,59,74,101,157,169],"various":[11],"fields":[12],"by":[13,104],"providing":[14],"scalable":[15],"and":[16,34,57,65,83,111,132,175,187],"readily":[17],"available":[18],"computational":[19],"resources,":[20],"enabling":[21],"efficient":[22],"data":[23,39],"processing.":[24],"These":[25,68],"advancements":[26,69],"have":[27,70],"significantly":[28],"enhanced":[29],"the":[30,43,53,60,75,89,130,142,148,161,185,188,191],"connectivity":[31],"between":[32],"local":[33],"remote":[35],"systems,":[36],"facilitating":[37],"streamlined":[38],"transmission":[40],"processes.":[41],"Furthermore,":[42],"adoption":[44],"Software":[46],"as":[47,81],"Service":[49],"models":[50],"allowed":[52],"hosting":[54],"programs":[56],"applications":[58,103],"cloud,":[61],"offering":[62],"accessibility,":[63],"scalability,":[64],"cost":[66],"savings.":[67],"not":[71],"gone":[72],"unnoticed":[73],"power":[76],"system":[77],"domain.":[78],"Applications":[79],"such":[80],"monitoring,":[82],"protection":[84],"can":[85],"take":[86],"advantage":[87],"improved":[90],"telecommunication":[91],"technology.":[92],"Phasor":[93],"Measurement":[94],"Units":[95],"(PMUs)":[96],"play":[97],"vital":[99],"role":[100],"these":[102],"synchronizing":[105],"quantities":[106,113],"obtained":[107],"from":[108],"instrument":[109],"transformers":[110],"computed":[112],"using":[114],"precise":[115],"time":[116],"stamps.":[117],"objective":[119],"this":[121,164,170],"paper":[122,171],"is":[123,172],"to":[124],"conduct":[125],"comprehensive":[127],"analysis":[128,168],"pros":[131],"cons":[133],"associated":[134],"with":[135],"cloud-based":[137],"PMU":[138,143],"(CB-PMU)":[139],"that":[140],"integrates":[141],"Synchrophasor":[144],"estimation":[145],"directly":[146],"into":[147],"infrastructure.":[150],"This":[151],"approach":[152],"received":[154],"limited":[155],"attention":[156],"existing":[158],"literature,":[159],"underscoring":[160],"necessity":[162],"for":[163,180],"in-depth":[165],"study.":[166],"both":[173],"theoretical":[174],"experimental.":[176],"results":[178],"allow":[179],"complete":[182],"assessment":[183],"applicability":[186],"limits":[189],"CB-PMU.":[192]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
