{"id":"https://openalex.org/W4388115966","doi":"https://doi.org/10.1109/amps59207.2023.10297215","title":"Is Reactive Power a Zero-Quantity?","display_name":"Is Reactive Power a Zero-Quantity?","publication_year":2023,"publication_date":"2023-09-27","ids":{"openalex":"https://openalex.org/W4388115966","doi":"https://doi.org/10.1109/amps59207.2023.10297215"},"language":"en","primary_location":{"id":"doi:10.1109/amps59207.2023.10297215","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297215","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016829902","display_name":"C.T. Gaunt","orcid":"https://orcid.org/0000-0001-7518-0446"},"institutions":[{"id":"https://openalex.org/I157614274","display_name":"University of Cape Town","ror":"https://ror.org/03p74gp79","country_code":"ZA","type":"education","lineage":["https://openalex.org/I157614274"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Charles Trevor GAUNT","raw_affiliation_strings":["University of Cape Town,Department of Electrical Engineering,Cape Town,South Africa","Department of Electrical Engineering, University of Cape Town, Cape Town, South Africa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cape Town,Department of Electrical Engineering,Cape Town,South Africa","institution_ids":["https://openalex.org/I157614274"]},{"raw_affiliation_string":"Department of Electrical Engineering, University of Cape Town, Cape Town, South Africa","institution_ids":["https://openalex.org/I157614274"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087478733","display_name":"Pitambar Jankee","orcid":"https://orcid.org/0000-0001-8006-2997"},"institutions":[{"id":"https://openalex.org/I157614274","display_name":"University of Cape Town","ror":"https://ror.org/03p74gp79","country_code":"ZA","type":"education","lineage":["https://openalex.org/I157614274"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Pitambar JANKEE","raw_affiliation_strings":["University of Cape Town,Department of Electrical Engineering,Cape Town,South Africa","Department of Electrical Engineering, University of Cape Town, Cape Town, South Africa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cape Town,Department of Electrical Engineering,Cape Town,South Africa","institution_ids":["https://openalex.org/I157614274"]},{"raw_affiliation_string":"Department of Electrical Engineering, University of Cape Town, Cape Town, South Africa","institution_ids":["https://openalex.org/I157614274"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I157614274"],"apc_list":null,"apc_paid":null,"fwci":0.5409,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.58000687,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"9","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/3103","display_name":"Astronomy and Astrophysics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.8249579668045044},{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.7490545511245728},{"id":"https://openalex.org/keywords/volt-ampere-reactive","display_name":"Volt-ampere reactive","score":0.5765087008476257},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.5641613006591797},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5614029169082642},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.5477655529975891},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5087698101997375},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.4885169267654419},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4872225821018219},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4844927489757538},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.4635426700115204},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.44022107124328613},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.42202675342559814},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4203353822231293},{"id":"https://openalex.org/keywords/volt-ampere","display_name":"Volt-ampere","score":0.4176808297634125},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3724483847618103},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3320472240447998},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3232042193412781},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.29478999972343445},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.14289838075637817},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.14070239663124084},{"id":"https://openalex.org/keywords/constant-power-circuit","display_name":"Constant power circuit","score":0.1163000762462616}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8249579668045044},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.7490545511245728},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.5765087008476257},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.5641613006591797},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5614029169082642},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.5477655529975891},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5087698101997375},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4885169267654419},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4872225821018219},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4844927489757538},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.4635426700115204},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.44022107124328613},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.42202675342559814},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4203353822231293},{"id":"https://openalex.org/C148367217","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere","level":5,"score":0.4176808297634125},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3724483847618103},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3320472240447998},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3232042193412781},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.29478999972343445},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14289838075637817},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.14070239663124084},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.1163000762462616},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/amps59207.2023.10297215","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297215","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1999952443","https://openalex.org/W2025100928","https://openalex.org/W2037710959","https://openalex.org/W2047753494","https://openalex.org/W2143593573","https://openalex.org/W2343155044","https://openalex.org/W3044860982","https://openalex.org/W4300818363","https://openalex.org/W6659910497","https://openalex.org/W6704532047","https://openalex.org/W6815062302"],"related_works":["https://openalex.org/W2389036270","https://openalex.org/W2353619345","https://openalex.org/W1557097199","https://openalex.org/W2595986840","https://openalex.org/W1710498555","https://openalex.org/W2365229855","https://openalex.org/W4238078686","https://openalex.org/W4390556732","https://openalex.org/W2369535890","https://openalex.org/W262321076"],"abstract_inverted_index":{"Reactive":[0],"power":[1,46,50,116,120],"has":[2,26],"been":[3],"defined":[4,53],"in":[5,10,75,111],"various":[6],"ways":[7],"and":[8,12,29,38,47,83,99,102,109,114,125,127],"discussed":[9],"technical":[11],"measurement":[13,107,129],"papers":[14],"almost":[15],"continuously":[16],"since":[17],"it":[18],"was":[19],"proposed.":[20],"For":[21],"over":[22],"100":[23],"years,":[24],"consensus":[25],"eluded":[27],"physicists":[28],"electrical":[30],"engineers.":[31],"This":[32],"paper":[33],"explores":[34],"the":[35,59],"physical,":[36],"mathematical,":[37],"practical":[39],"aspects":[40],"of":[41],"reactive":[42,55],"power.":[43],"Average":[44],"(active)":[45],"average":[48,60],"apparent":[49],"can":[51],"be":[52],"without":[54],"power,":[56],"for":[57,80,100,106,136],"which":[58],"is":[61],"always":[62],"zero.":[63],"Two":[64],"definitions":[65],"are":[66,130,133],"proposed":[67],"that":[68],"apply":[69],"consistently":[70],"to":[71],"all":[72],"systems":[73,108,117],"operating":[74],"relatively":[76],"steady":[77],"state":[78],"-":[79,88],"an":[81],"apparatus":[82],"within":[84],"a":[85],"delivery":[86],"system":[87],"with":[89],"balance":[90],"or":[91,95,139],"unbalance,":[92],"sinusoidal":[93],"waveforms":[94],"distorted":[96],"by":[97],"harmonics,":[98],"ac":[101],"dc.":[103],"The":[104],"implications":[105,135],"devices":[110],"smart":[112],"grids":[113],"conventional":[115],"(including":[118],"control),":[119],"quality":[121],"standards,":[122],"revenue":[123],"metering,":[124],"scientific":[126],"legal":[128],"outlined.":[131],"There":[132],"also":[134],"defining":[137],"dynamic":[138],"transient":[140],"parameters.":[141]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
