{"id":"https://openalex.org/W4388115950","doi":"https://doi.org/10.1109/amps59207.2023.10297185","title":"Revenue Metrics Ability to Correctly Register Bidirectional Active Energy Flows in Active Distribution Networks","display_name":"Revenue Metrics Ability to Correctly Register Bidirectional Active Energy Flows in Active Distribution Networks","publication_year":2023,"publication_date":"2023-09-27","ids":{"openalex":"https://openalex.org/W4388115950","doi":"https://doi.org/10.1109/amps59207.2023.10297185"},"language":"en","primary_location":{"id":"doi:10.1109/amps59207.2023.10297185","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297185","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089030694","display_name":"Jan Klus\u00e1\u010dek","orcid":"https://orcid.org/0000-0001-9952-8697"},"institutions":[{"id":"https://openalex.org/I60587646","display_name":"Brno University of Technology","ror":"https://ror.org/03613d656","country_code":"CZ","type":"education","lineage":["https://openalex.org/I60587646"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Jan Klusacek","raw_affiliation_strings":["Brno University of Technology,Faculty of Electrical Engineering and Communication,Dept. of Electrical Power Engineering,Brno,Czech Republic","Dept. of Electrical Power Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Brno University of Technology,Faculty of Electrical Engineering and Communication,Dept. of Electrical Power Engineering,Brno,Czech Republic","institution_ids":["https://openalex.org/I60587646"]},{"raw_affiliation_string":"Dept. of Electrical Power Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic","institution_ids":["https://openalex.org/I60587646"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067978711","display_name":"Ji\u0159\u00ed Dr\u00e1pela","orcid":"https://orcid.org/0000-0003-4437-6360"},"institutions":[{"id":"https://openalex.org/I60587646","display_name":"Brno University of Technology","ror":"https://ror.org/03613d656","country_code":"CZ","type":"education","lineage":["https://openalex.org/I60587646"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Jiri Drapela","raw_affiliation_strings":["Brno University of Technology,Faculty of Electrical Engineering and Communication,Dept. of Electrical Power Engineering,Brno,Czech Republic","Dept. of Electrical Power Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Brno University of Technology,Faculty of Electrical Engineering and Communication,Dept. of Electrical Power Engineering,Brno,Czech Republic","institution_ids":["https://openalex.org/I60587646"]},{"raw_affiliation_string":"Dept. of Electrical Power Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic","institution_ids":["https://openalex.org/I60587646"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062952220","display_name":"Roberto Langella","orcid":"https://orcid.org/0000-0002-9272-8423"},"institutions":[{"id":"https://openalex.org/I197809005","display_name":"University of Campania \"Luigi Vanvitelli\"","ror":"https://ror.org/02kqnpp86","country_code":"IT","type":"education","lineage":["https://openalex.org/I197809005"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Langella","raw_affiliation_strings":["University of Campania Luigi Vanvitelli,Department of Engineering,Aversa,Italy","Department of Engineering, University of Campania Luigi Vanvitelli, Aversa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Campania Luigi Vanvitelli,Department of Engineering,Aversa,Italy","institution_ids":["https://openalex.org/I197809005"]},{"raw_affiliation_string":"Department of Engineering, University of Campania Luigi Vanvitelli, Aversa, Italy","institution_ids":["https://openalex.org/I197809005"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004418749","display_name":"Jan Meyer","orcid":"https://orcid.org/0000-0002-6884-5101"},"institutions":[{"id":"https://openalex.org/I4405254611","display_name":"Institute of Electrical Power Systems and High Voltage Engineering","ror":"https://ror.org/020z28a80","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4405254611","https://openalex.org/I78650965"]},{"id":"https://openalex.org/I78650965","display_name":"Technische Universit\u00e4t Dresden","ror":"https://ror.org/042aqky30","country_code":"DE","type":"education","lineage":["https://openalex.org/I78650965"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jan Meyer","raw_affiliation_strings":["Institute of Electrical Power Systems and High Voltage Engineering Technische Universit&#x00E4;t Dresden,Dresden,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electrical Power Systems and High Voltage Engineering Technische Universit&#x00E4;t Dresden,Dresden,Germany","institution_ids":["https://openalex.org/I4405254611","https://openalex.org/I78650965"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"46","issue":null,"first_page":"01","last_page":"06"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6408843398094177},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.607434868812561},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.5831762552261353},{"id":"https://openalex.org/keywords/revenue","display_name":"Revenue","score":0.5664232969284058},{"id":"https://openalex.org/keywords/active-networking","display_name":"Active networking","score":0.5432736277580261},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.528622031211853},{"id":"https://openalex.org/keywords/set","display_name":"Set (abstract data type)","score":0.45302292704582214},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4377988576889038},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4233928322792053},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.41944313049316406},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.3365320563316345},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.33301204442977905},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.32911795377731323},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.21141603589057922},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19197803735733032},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17173120379447937},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.15042072534561157},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.11014282703399658},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.09377369284629822},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.07953265309333801}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6408843398094177},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.607434868812561},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.5831762552261353},{"id":"https://openalex.org/C195487862","wikidata":"https://www.wikidata.org/wiki/Q850210","display_name":"Revenue","level":2,"score":0.5664232969284058},{"id":"https://openalex.org/C102665078","wikidata":"https://www.wikidata.org/wiki/Q4677571","display_name":"Active networking","level":2,"score":0.5432736277580261},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.528622031211853},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.45302292704582214},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4377988576889038},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4233928322792053},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.41944313049316406},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3365320563316345},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.33301204442977905},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.32911795377731323},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.21141603589057922},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19197803735733032},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17173120379447937},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15042072534561157},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11014282703399658},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.09377369284629822},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.07953265309333801},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121955636","wikidata":"https://www.wikidata.org/wiki/Q4116214","display_name":"Accounting","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/amps59207.2023.10297185","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/amps59207.2023.10297185","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2023429596","https://openalex.org/W2056950201","https://openalex.org/W2486391884","https://openalex.org/W2498683444","https://openalex.org/W2566503032","https://openalex.org/W2745081715","https://openalex.org/W2897149028","https://openalex.org/W3082484050","https://openalex.org/W4200384090","https://openalex.org/W4205345560","https://openalex.org/W4205390220","https://openalex.org/W4246785589"],"related_works":["https://openalex.org/W4312311708","https://openalex.org/W2006004274","https://openalex.org/W2042023873","https://openalex.org/W1518483596","https://openalex.org/W2372464858","https://openalex.org/W2900490168","https://openalex.org/W2893865120","https://openalex.org/W2606753762","https://openalex.org/W3202593640","https://openalex.org/W2347116682"],"abstract_inverted_index":{"Distributed":[0],"generation":[1],"in":[2,12,17,48,88,154],"combination":[3],"with":[4,30],"switching":[5],"adaptive":[6],"loads":[7],"providing":[8],"optimized":[9],"energy":[10,20,81,121,130,157,183],"management":[11],"the":[13,23,34,42,57,61,68,79,101,113,119,140,150,155,164,167,173,177,180],"prosumers'":[14],"installations":[15],"results":[16,138],"bidirectional":[18],"active":[19,80,97,120,129,156,182],"flow.":[21],"If":[22],"changes":[24,153],"are":[25,84],"frequent":[26],"or":[27,91],"even":[28],"periodical":[29],"period":[31],"close":[32],"to":[33,67,116,125],"aggregation":[35],"time":[36],"window":[37],"of":[38,59,63,78,96,105,112,142,149,152,166],"standard":[39],"revenue":[40,89],"meters,":[41],"deviation":[43],"from":[44,93],"really":[45],"correct":[46],"readings":[47],"export":[49,133],"and":[50,110,132,179],"import":[51,131],"registers":[52],"might":[53,71],"be":[54],"significant.":[55],"Subsequently,":[56],"concepts":[58],"allocating":[60],"costs":[62],"distribution":[64],"system":[65],"operation":[66],"network":[69],"users":[70],"fail.":[72],"The":[73,137],"paper":[74],"presents":[75],"an":[76],"overview":[77],"metrics,":[82],"which":[83],"either":[85],"already":[86],"implemented":[87],"meters":[90],"derived":[92],"other":[94],"applications":[95],"power":[98],"measurement.":[99],"In":[100],"paper,":[102],"a":[103,147],"set":[104],"test":[106],"scenarios":[107],"is":[108,134,161],"proposed":[109],"analysis":[111],"metrics":[114,170],"ability":[115],"account":[117],"for":[118],"flow":[122,158],"and,":[123],"subsequently,":[124],"correctly":[126],"distinguish":[127],"between":[128,176],"carried":[135],"out.":[136],"show":[139],"limitations":[141],"each":[143],"metric":[144],"considered":[145],"as":[146],"function":[148],"frequency/rate":[151],"direction.":[159],"It":[160],"demonstrated":[162],"that":[163],"performance":[165],"most":[168],"adopted":[169],"exhibits":[171],"potentially":[172],"largest":[174],"mismatch":[175],"measurements":[178],"actual":[181],"flows.":[184]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
