{"id":"https://openalex.org/W2982808458","doi":"https://doi.org/10.1109/amps.2019.8897788","title":"Design and Testing of a Setup for On-Site Power Measurements in High-Voltage Grids","display_name":"Design and Testing of a Setup for On-Site Power Measurements in High-Voltage Grids","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2982808458","doi":"https://doi.org/10.1109/amps.2019.8897788","mag":"2982808458"},"language":"en","primary_location":{"id":"doi:10.1109/amps.2019.8897788","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2019.8897788","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073844637","display_name":"Gert Rietveld","orcid":"https://orcid.org/0000-0002-5239-4019"},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"Gert Rietveld","raw_affiliation_strings":["Electricity and Time Department VSL,Delft,The Netherlands","Electricity and Time Department VSL, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Electricity and Time Department VSL,Delft,The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":"Electricity and Time Department VSL, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026659970","display_name":"M. Fransen","orcid":"https://orcid.org/0000-0002-0932-2984"},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Martin Fransen","raw_affiliation_strings":["Electricity and Time Department VSL,Delft,The Netherlands","Electricity and Time Department VSL, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Electricity and Time Department VSL,Delft,The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":"Electricity and Time Department VSL, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066789085","display_name":"Nicolas V.F. Blanc","orcid":null},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Nicolas V.F. Blanc","raw_affiliation_strings":["Electricity and Time Department VSL,Delft,The Netherlands","Electricity and Time Department VSL, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Electricity and Time Department VSL,Delft,The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":"Electricity and Time Department VSL, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5029874260","display_name":"E. So","orcid":"https://orcid.org/0000-0001-9666-6226"},"institutions":[{"id":"https://openalex.org/I197604219","display_name":"National Academies of Sciences, Engineering, and Medicine","ror":"https://ror.org/02eq2w707","country_code":"US","type":"government","lineage":["https://openalex.org/I197604219"]},{"id":"https://openalex.org/I4210159778","display_name":"National Research Council Canada","ror":"https://ror.org/04mte1k06","country_code":"CA","type":"government","lineage":["https://openalex.org/I4210159778"]}],"countries":["CA","US"],"is_corresponding":false,"raw_author_name":"Eddy So","raw_affiliation_strings":["HV Power and Energy Group, National Research Council, NRC,Ottawa,Canada","HV Power and Energy Group, National Research Council, NRC, Ottawa, Canada"],"affiliations":[{"raw_affiliation_string":"HV Power and Energy Group, National Research Council, NRC,Ottawa,Canada","institution_ids":["https://openalex.org/I4210159778","https://openalex.org/I197604219"]},{"raw_affiliation_string":"HV Power and Energy Group, National Research Council, NRC, Ottawa, Canada","institution_ids":["https://openalex.org/I4210159778"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5073844637"],"corresponding_institution_ids":["https://openalex.org/I4210164637"],"apc_list":null,"apc_paid":null,"fwci":0.2387,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.56150223,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12510","display_name":"Magneto-Optical Properties and Applications","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.65090012550354},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6396327018737793},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.6003551483154297},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.5732197761535645},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5691441893577576},{"id":"https://openalex.org/keywords/high-voltage","display_name":"High voltage","score":0.5615785717964172},{"id":"https://openalex.org/keywords/electricity-meter","display_name":"Electricity meter","score":0.5287156701087952},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.5280680656433105},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5094993710517883},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44406843185424805},{"id":"https://openalex.org/keywords/metre","display_name":"Metre","score":0.42085155844688416},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.41704171895980835},{"id":"https://openalex.org/keywords/system-of-measurement","display_name":"System of measurement","score":0.41475623846054077},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4008861184120178},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3951950669288635},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3286746144294739},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.185104638338089},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.06972503662109375}],"concepts":[{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.65090012550354},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6396327018737793},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6003551483154297},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5732197761535645},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5691441893577576},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.5615785717964172},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.5287156701087952},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.5280680656433105},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5094993710517883},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44406843185424805},{"id":"https://openalex.org/C151011524","wikidata":"https://www.wikidata.org/wiki/Q11573","display_name":"Metre","level":2,"score":0.42085155844688416},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.41704171895980835},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.41475623846054077},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4008861184120178},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3951950669288635},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3286746144294739},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.185104638338089},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.06972503662109375},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/amps.2019.8897788","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2019.8897788","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},{"id":"pmh:oai:cisti-icist.nrc-cnrc.ca:cistinparc:ffb1ecc2-77ee-4076-bb33-1d3d2d85e06e","is_oa":false,"landing_page_url":"https://nrc-publications.canada.ca/eng/view/object/?id=ffb1ecc2-77ee-4076-bb33-1d3d2d85e06e","pdf_url":null,"source":{"id":"https://openalex.org/S7407055245","display_name":"NPARC","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7400000095367432,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2022751197","https://openalex.org/W2108600657","https://openalex.org/W2148072285","https://openalex.org/W4210809922"],"related_works":["https://openalex.org/W2388136019","https://openalex.org/W2359630406","https://openalex.org/W2289935687","https://openalex.org/W2914461365","https://openalex.org/W2034434590","https://openalex.org/W2382973115","https://openalex.org/W2353890496","https://openalex.org/W4379377656","https://openalex.org/W2356012022","https://openalex.org/W2393627087"],"abstract_inverted_index":{"A":[0],"three-phase":[1,24],"reference":[2,37],"system":[3,38,49,77],"for":[4],"in-situ":[5],"calibration":[6,63],"of":[7,21,41,61,67,79],"High":[8],"Voltage":[9],"(HV)":[10],"Revenue":[11],"Metering":[12],"Systems":[13],"in":[14],"substations":[15],"has":[16],"been":[17],"established.":[18],"It":[19],"consists":[20],"a":[22],"high-accuracy":[23],"power":[25,43,68],"meter,":[26,69],"including":[27],"corresponding":[28],"current":[29],"and":[30,34,51,64,71],"voltage":[31,50],"transformers":[32],"(CTs":[33],"VTs).":[35],"The":[36,58],"is":[39],"capable":[40],"performing":[42],"measurements":[44],"up":[45,54],"to":[46,55],"150":[47],"kV":[48],"line":[52],"currents":[53],"5000":[56],"A.":[57],"excellent":[59],"results":[60],"the":[62],"further":[65],"testing":[66],"CTs,":[70],"VTs":[72],"indicate":[73],"that":[74],"an":[75],"overall":[76],"uncertainty":[78],"better":[80],"than":[81],"100\u03bcW/VA":[82],"can":[83],"be":[84],"achieved.":[85]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2026-03-02T08:37:19.008085","created_date":"2025-10-10T00:00:00"}
