{"id":"https://openalex.org/W2896179116","doi":"https://doi.org/10.1109/amps.2018.8494887","title":"Calibration of Synchronized Measurement System: from the Instrument Transformer to the PMU","display_name":"Calibration of Synchronized Measurement System: from the Instrument Transformer to the PMU","publication_year":2018,"publication_date":"2018-09-01","ids":{"openalex":"https://openalex.org/W2896179116","doi":"https://doi.org/10.1109/amps.2018.8494887","mag":"2896179116"},"language":"en","primary_location":{"id":"doi:10.1109/amps.2018.8494887","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2018.8494887","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://hdl.handle.net/11585/649335","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5012455420","display_name":"Alessandro Mingotti","orcid":"https://orcid.org/0000-0002-1739-1277"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"A. Mingotti","raw_affiliation_strings":["Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018213030","display_name":"Lorenzo Peretto","orcid":"https://orcid.org/0000-0003-3407-2056"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"L. Peretto","raw_affiliation_strings":["Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088604112","display_name":"Roberto Tinarelli","orcid":"https://orcid.org/0000-0002-5377-2421"},"institutions":[{"id":"https://openalex.org/I9360294","display_name":"University of Bologna","ror":"https://ror.org/01111rn36","country_code":"IT","type":"education","lineage":["https://openalex.org/I9360294"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"R. Tinarelli","raw_affiliation_strings":["Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical, Electronic and Information Engineering Alma Mater Studiorum - University of Bologna, Bologna, Italy","institution_ids":["https://openalex.org/I9360294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080014786","display_name":"Andrea Angioni","orcid":"https://orcid.org/0000-0002-2749-8465"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"A. Angioni","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030410007","display_name":"Antonello Monti","orcid":"https://orcid.org/0000-0003-1914-9801"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"A. Monti","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043977449","display_name":"Ferdinanda Ponci","orcid":"https://orcid.org/0000-0003-0431-9169"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"F. Ponci","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, RWTH University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":22,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12510","display_name":"Magneto-Optical Properties and Applications","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6996403336524963},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.6829730272293091},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.6306109428405762},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.629113495349884},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.6066465973854065},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6041368842124939},{"id":"https://openalex.org/keywords/system-of-measurement","display_name":"System of measurement","score":0.5739391446113586},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5448110699653625},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.5285598039627075},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.5209121108055115},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.49932432174682617},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4947754740715027},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.48026394844055176},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.47370976209640503},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.46755683422088623},{"id":"https://openalex.org/keywords/power-network","display_name":"Power network","score":0.4305630326271057},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.38789501786231995},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3131347894668579},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.24074023962020874}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6996403336524963},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.6829730272293091},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.6306109428405762},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.629113495349884},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.6066465973854065},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6041368842124939},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.5739391446113586},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5448110699653625},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.5285598039627075},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.5209121108055115},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.49932432174682617},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4947754740715027},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.48026394844055176},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.47370976209640503},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.46755683422088623},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.4305630326271057},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.38789501786231995},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3131347894668579},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.24074023962020874},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/amps.2018.8494887","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2018.8494887","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},{"id":"pmh:oai:cris.unibo.it:11585/649335","is_oa":true,"landing_page_url":"http://hdl.handle.net/11585/649335","pdf_url":null,"source":{"id":"https://openalex.org/S4306402579","display_name":"Archivio istituzionale della ricerca (Alma Mater Studiorum Universit\u00e0 di Bologna)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210117483","host_organization_name":"Istituto di Ematologia di Bologna","host_organization_lineage":["https://openalex.org/I4210117483"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:publications.rwth-aachen.de:751319","is_oa":false,"landing_page_url":"https://publications.rwth-aachen.de/record/751319","pdf_url":null,"source":{"id":"https://openalex.org/S4306401362","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Piscataway, NJ : IEEE (2018). doi:10.1109/AMPS.2018.8494887","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:cris.unibo.it:11585/649335","is_oa":true,"landing_page_url":"http://hdl.handle.net/11585/649335","pdf_url":null,"source":{"id":"https://openalex.org/S4306402579","display_name":"Archivio istituzionale della ricerca (Alma Mater Studiorum Universit\u00e0 di Bologna)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210117483","host_organization_name":"Istituto di Ematologia di Bologna","host_organization_lineage":["https://openalex.org/I4210117483"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.4099999964237213,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W2094455106","https://openalex.org/W2605195494","https://openalex.org/W2735108522","https://openalex.org/W2763649687","https://openalex.org/W2766496513","https://openalex.org/W2766705097","https://openalex.org/W2774935576","https://openalex.org/W2805541463","https://openalex.org/W2823858483","https://openalex.org/W2901388029","https://openalex.org/W4200141286","https://openalex.org/W6752893418","https://openalex.org/W6755944440"],"related_works":["https://openalex.org/W2182509182","https://openalex.org/W2125787228","https://openalex.org/W2138143921","https://openalex.org/W1923806246","https://openalex.org/W2547260311","https://openalex.org/W2166008706","https://openalex.org/W2102650188","https://openalex.org/W4244071503","https://openalex.org/W2582236778","https://openalex.org/W2102647849"],"abstract_inverted_index":{"Even":[0],"if":[1],"their":[2,36,50],"deployment":[3],"in":[4,40,67,77,106],"electrical":[5],"medium":[6,41],"voltage":[7,42],"networks":[8],"was":[9],"not":[10,74],"as":[11,13,46],"extensive":[12],"could":[14],"be":[15],"expected":[16],"at":[17],"the":[18,62,78,84,89,107],"beginning,":[19],"Phasor":[20],"Measurement":[21],"Units":[22],"are":[23,61],"key":[24],"elements":[25],"for":[26],"Smart":[27],"Grid":[28],"operation.":[29],"An":[30],"impressive":[31],"amount":[32],"of":[33,65,91],"papers":[34],"discusses":[35],"implementation":[37],"and":[38,44,99],"usefulness":[39],"network":[43],"almost":[45],"many":[47],"deals":[48],"with":[49],"metrological":[51],"characterization.":[52],"Although":[53],"it":[54],"is":[55,73,86],"well":[56],"known":[57],"that":[58],"instrument":[59,102],"transformers":[60],"main":[63],"source":[64],"uncertainty":[66],"PMU-based":[68],"synchronized":[69],"measurements,":[70],"this":[71,82],"topic":[72],"sufficiently":[75],"tackled":[76],"scientific":[79],"literature.":[80],"In":[81],"paper,":[83],"attention":[85],"focused":[87],"on":[88],"calibration":[90],"a":[92,97,100],"measurement":[93],"system":[94],"made":[95],"by":[96],"PMU":[98],"low-power":[101],"transformer":[103],"commonly":[104],"employed":[105],"Italian":[108],"distribution":[109],"network.":[110]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":8}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
