{"id":"https://openalex.org/W2047086308","doi":"https://doi.org/10.1109/amps.2014.6947715","title":"IEC 61850-based logic selectivity scheme for the MV distribution network","display_name":"IEC 61850-based logic selectivity scheme for the MV distribution network","publication_year":2014,"publication_date":"2014-09-01","ids":{"openalex":"https://openalex.org/W2047086308","doi":"https://doi.org/10.1109/amps.2014.6947715","mag":"2047086308"},"language":"en","primary_location":{"id":"doi:10.1109/amps.2014.6947715","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2014.6947715","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Workshop on Applied Measurements for Power Systems Proceedings (AMPS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079462976","display_name":"Alessio Ded\u00e9","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"A. Dede","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy","A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]},{"raw_affiliation_string":"A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079635867","display_name":"Davide Della Giustina","orcid":"https://orcid.org/0000-0002-8311-7145"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"D. Della Giustina","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy","A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]},{"raw_affiliation_string":"A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038040150","display_name":"Faustino Franzoni","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"F. Franzoni","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy","A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]},{"raw_affiliation_string":"A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026836403","display_name":"Andrea Pegoiani","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"A. Pegoiani","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy","A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]},{"raw_affiliation_string":"A2A Reti Elettriche SpA Via Lamarmora 230,25124 Brescia, Italy","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.9575014114379883},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.7414294481277466},{"id":"https://openalex.org/keywords/it-service-continuity","display_name":"IT service continuity","score":0.5650836229324341},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5334810018539429},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4743714928627014},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4506152868270874},{"id":"https://openalex.org/keywords/service","display_name":"Service (business)","score":0.44710734486579895},{"id":"https://openalex.org/keywords/process-automation-system","display_name":"Process automation system","score":0.44220033288002014},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.39762750267982483},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3499391973018646},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2295304834842682}],"concepts":[{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.9575014114379883},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.7414294481277466},{"id":"https://openalex.org/C67069471","wikidata":"https://www.wikidata.org/wiki/Q1140205","display_name":"IT service continuity","level":2,"score":0.5650836229324341},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5334810018539429},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4743714928627014},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4506152868270874},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.44710734486579895},{"id":"https://openalex.org/C21457203","wikidata":"https://www.wikidata.org/wiki/Q4056293","display_name":"Process automation system","level":3,"score":0.44220033288002014},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.39762750267982483},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3499391973018646},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2295304834842682},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C136264566","wikidata":"https://www.wikidata.org/wiki/Q159810","display_name":"Economy","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/amps.2014.6947715","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2014.6947715","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Workshop on Applied Measurements for Power Systems Proceedings (AMPS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.6100000143051147}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1968887744","https://openalex.org/W2049673305","https://openalex.org/W2536973157","https://openalex.org/W2537604312","https://openalex.org/W4243504749"],"related_works":["https://openalex.org/W2051546191","https://openalex.org/W2367313724","https://openalex.org/W2130861944","https://openalex.org/W2369068088","https://openalex.org/W2381742191","https://openalex.org/W2390581407","https://openalex.org/W2183876688","https://openalex.org/W2384002254","https://openalex.org/W2358803933","https://openalex.org/W2167610914"],"abstract_inverted_index":{"The":[0,12,78],"electricity":[1,16],"distribution":[2,17],"network":[3],"is":[4,19,26,43,115],"a":[5,21,72,81,101],"critical":[6],"infrastructure":[7],"of":[8,14,45,66,107,112],"the":[9,15,33,46,55,59,62,67,85,91],"modern":[10],"society.":[11],"continuity":[13],"service":[18,30],"therefore":[20],"key":[22],"topic.":[23],"Network":[24],"automation":[25,36],"aimed":[27],"at":[28,61],"improving":[29],"continuity.":[31],"Among":[32],"several":[34],"possible":[35],"schemes,":[37],"logic":[38,86],"selectivity":[39,87],"between":[40],"protection":[41],"relays":[42,99],"one":[44],"most":[47],"effective":[48],"approach":[49],"because":[50],"it":[51],"allow":[52],"to":[53,75,100],"reduce":[54],"area":[56],"affected":[57],"by":[58],"fault":[60,114],"very":[63],"same":[64],"time":[65],"event.":[68],"IEC":[69,92],"61850":[70,93],"provides":[71],"standard":[73],"way":[74],"implement":[76],"automation.":[77],"paper":[79],"describes":[80],"laboratory":[82],"setup":[83],"where":[84],"-":[88,94],"based":[89],"on":[90],"was":[95],"tested":[96],"before":[97],"moving":[98],"real":[102],"field":[103],"demonstrator.":[104],"An":[105],"analysis":[106],"system":[108],"performance":[109],"in":[110],"presence":[111],"phase-to-ground":[113],"reported.":[116]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":4}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}