{"id":"https://openalex.org/W2050889750","doi":"https://doi.org/10.1109/amps.2011.6090435","title":"ICT architecture for an integrated distribution network monitoring","display_name":"ICT architecture for an integrated distribution network monitoring","publication_year":2011,"publication_date":"2011-09-01","ids":{"openalex":"https://openalex.org/W2050889750","doi":"https://doi.org/10.1109/amps.2011.6090435","mag":"2050889750"},"language":"en","primary_location":{"id":"doi:10.1109/amps.2011.6090435","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2011.6090435","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079635867","display_name":"Davide Della Giustina","orcid":"https://orcid.org/0000-0002-8311-7145"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"D. Della Giustina","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy"],"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060320653","display_name":"Sami Repo","orcid":"https://orcid.org/0000-0002-7303-8283"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]},{"id":"https://openalex.org/I150589677","display_name":"Tampere University of Applied Sciences","ror":"https://ror.org/00bwtjf83","country_code":"FI","type":"education","lineage":["https://openalex.org/I150589677"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"S. Repo","raw_affiliation_strings":["Department of Electrical Energy Engineering, Tampere University of Technology, Tampere, Finland","Dept. of Electr. Energy Eng., Tampere Univ. of Technol., Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Energy Engineering, Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]},{"raw_affiliation_string":"Dept. of Electr. Energy Eng., Tampere Univ. of Technol., Tampere, Finland","institution_ids":["https://openalex.org/I150589677"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060814027","display_name":"Samuele Zanini","orcid":"https://orcid.org/0009-0007-7655-3313"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S. Zanini","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy"],"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5081408539","display_name":"L. Cremaschini","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"L. Cremaschini","raw_affiliation_strings":["A2A Reti Elettriche SpA, Brescia, Italy"],"affiliations":[{"raw_affiliation_string":"A2A Reti Elettriche SpA, Brescia, Italy","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5079635867"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.5676,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.94517577,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":"2","issue":null,"first_page":"102","last_page":"106"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.992900013923645,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7544232606887817},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.697250485420227},{"id":"https://openalex.org/keywords/exploit","display_name":"Exploit","score":0.689932107925415},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6483930945396423},{"id":"https://openalex.org/keywords/architecture","display_name":"Architecture","score":0.5511314272880554},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.5320582985877991},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5128858089447021},{"id":"https://openalex.org/keywords/information-and-communications-technology","display_name":"Information and Communications Technology","score":0.4863060414791107},{"id":"https://openalex.org/keywords/service","display_name":"Service (business)","score":0.4604310393333435},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4278033375740051},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3568740487098694},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.3293676972389221},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19107121229171753},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17539140582084656},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.14383181929588318},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.12871044874191284},{"id":"https://openalex.org/keywords/world-wide-web","display_name":"World Wide Web","score":0.11756914854049683}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7544232606887817},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.697250485420227},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.689932107925415},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6483930945396423},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.5511314272880554},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.5320582985877991},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5128858089447021},{"id":"https://openalex.org/C67363961","wikidata":"https://www.wikidata.org/wiki/Q5268834","display_name":"Information and Communications Technology","level":2,"score":0.4863060414791107},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.4604310393333435},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4278033375740051},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3568740487098694},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3293676972389221},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19107121229171753},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17539140582084656},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.14383181929588318},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.12871044874191284},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.11756914854049683},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C136264566","wikidata":"https://www.wikidata.org/wiki/Q159810","display_name":"Economy","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/amps.2011.6090435","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2011.6090435","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7400000095367432,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320338370","display_name":"FP7 Information and Communication Technologies","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1758048965","https://openalex.org/W2010957736","https://openalex.org/W2986769529","https://openalex.org/W6637835577"],"related_works":["https://openalex.org/W17155033","https://openalex.org/W3207760230","https://openalex.org/W1496222301","https://openalex.org/W1590307681","https://openalex.org/W2536018345","https://openalex.org/W4312814274","https://openalex.org/W4285370786","https://openalex.org/W2296488620","https://openalex.org/W2593427583","https://openalex.org/W2136076430"],"abstract_inverted_index":{"To":[0],"improve":[1],"quality":[2],"of":[3,5,21],"service":[4],"the":[6,22,55,64,89],"electrical":[7],"energy":[8,14],"distribution":[9],"and":[10,34,42,71,74,84],"to":[11,28,39,79],"exploit":[12],"distributed":[13,17,73],"resources":[15],"(e.g.":[16],"generation)":[18],"real-time":[19],"monitoring":[20],"power":[23],"grid":[24],"should":[25],"be":[26],"extended":[27],"include":[29],"secondary":[30],"substations,":[31],"medium":[32],"voltage":[33,36],"low":[35],"grids,":[37],"up":[38],"end-users,":[40],"gathering":[41],"processing":[43],"all":[44],"these":[45],"data":[46],"where":[47],"they":[48],"are":[49],"really":[50],"needed.":[51],"The":[52],"paper":[53],"describes":[54],"Integrated":[56],"Distribution":[57],"Network":[58],"Monitoring":[59],"use":[60],"case":[61],"defined":[62],"by":[63],"7th":[65],"Framework":[66],"Program":[67],"European":[68],"Project":[69],"INTEGRIS":[70],"its":[72],"hierarchical":[75],"ICT":[76],"architecture":[77],"designed":[78],"efficiently":[80],"fulfill":[81],"both":[82],"communication":[83],"application":[85],"requirements":[86],"foreseen":[87],"for":[88],"Smart":[90],"Grid.":[91]},"counts_by_year":[{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
