{"id":"https://openalex.org/W4388039917","doi":"https://doi.org/10.1109/africon55910.2023.10293538","title":"Monitoring of Solar Photovoltaic Plant Power Transformers Using Sweep Frequency Response Analysis","display_name":"Monitoring of Solar Photovoltaic Plant Power Transformers Using Sweep Frequency Response Analysis","publication_year":2023,"publication_date":"2023-09-20","ids":{"openalex":"https://openalex.org/W4388039917","doi":"https://doi.org/10.1109/africon55910.2023.10293538"},"language":"en","primary_location":{"id":"doi:10.1109/africon55910.2023.10293538","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/africon55910.2023.10293538","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE AFRICON","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060374145","display_name":"Fredrick Mukundi Mwaniki","orcid":"https://orcid.org/0000-0003-1466-4484"},"institutions":[{"id":"https://openalex.org/I26092322","display_name":"Stellenbosch University","ror":"https://ror.org/05bk57929","country_code":"ZA","type":"education","lineage":["https://openalex.org/I26092322"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Fredrick Mukundi Mwaniki","raw_affiliation_strings":["Stellenbosch University,Dept. of Electrical and Electronic Engineering,Stellenbosch,South Africa","Dept. of Electrical and Electronic Engineering, Stellenbosch University, Stellenbosch, South Africa"],"raw_orcid":"https://orcid.org/0000-0003-1466-4484","affiliations":[{"raw_affiliation_string":"Stellenbosch University,Dept. of Electrical and Electronic Engineering,Stellenbosch,South Africa","institution_ids":["https://openalex.org/I26092322"]},{"raw_affiliation_string":"Dept. of Electrical and Electronic Engineering, Stellenbosch University, Stellenbosch, South Africa","institution_ids":["https://openalex.org/I26092322"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074222005","display_name":"Ahmed Ali Sayyid","orcid":null},"institutions":[{"id":"https://openalex.org/I12859529","display_name":"University of Nairobi","ror":"https://ror.org/02y9nww90","country_code":"KE","type":"education","lineage":["https://openalex.org/I12859529"]}],"countries":["KE"],"is_corresponding":false,"raw_author_name":"Ahmed Ali Sayyid","raw_affiliation_strings":["University of Nairobi,Dept. of Electrical and Information Engineering,Nairobi,Kenya","Dept. of Electrical and Information Engineering, University of Nairobi, Nairobi, Kenya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Nairobi,Dept. of Electrical and Information Engineering,Nairobi,Kenya","institution_ids":["https://openalex.org/I12859529"]},{"raw_affiliation_string":"Dept. of Electrical and Information Engineering, University of Nairobi, Nairobi, Kenya","institution_ids":["https://openalex.org/I12859529"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040804755","display_name":"A. Escudero","orcid":null},"institutions":[{"id":"https://openalex.org/I4210091648","display_name":"TMO Renewables (United Kingdom)","ror":"https://ror.org/003fzn994","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210091648"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Andr\u00e9s Escudero","raw_affiliation_strings":["Grupotec Renewables Limited,Operation &#x0026; Maintenance Division,London,U.K"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grupotec Renewables Limited,Operation &#x0026; Maintenance Division,London,U.K","institution_ids":["https://openalex.org/I4210091648"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Brian Nyangaresi","orcid":null},"institutions":[{"id":"https://openalex.org/I1315810332","display_name":"Altair Engineering (United States)","ror":"https://ror.org/05939ef94","country_code":"US","type":"company","lineage":["https://openalex.org/I1315810332"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Brian Nyangaresi","raw_affiliation_strings":["Altair Systems Ltd (Kenya),Testing &#x0026; Comissioning Divison,Nairobi,Kenya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Altair Systems Ltd (Kenya),Testing &#x0026; Comissioning Divison,Nairobi,Kenya","institution_ids":["https://openalex.org/I1315810332"]}]},{"author_position":"last","author":{"id":null,"display_name":"Silvester Mukaisi","orcid":null},"institutions":[{"id":"https://openalex.org/I1315810332","display_name":"Altair Engineering (United States)","ror":"https://ror.org/05939ef94","country_code":"US","type":"company","lineage":["https://openalex.org/I1315810332"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Silvester Mukaisi","raw_affiliation_strings":["Altair Systems Ltd (Kenya),Testing &#x0026; Comissioning Divison,Nairobi,Kenya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Altair Systems Ltd (Kenya),Testing &#x0026; Comissioning Divison,Nairobi,Kenya","institution_ids":["https://openalex.org/I1315810332"]}]}],"institutions":[],"countries_distinct_count":4,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.12569578,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"5","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9969000220298767,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9925000071525574,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sweep-frequency-response-analysis","display_name":"Sweep frequency response analysis","score":0.6693669557571411},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6074658036231995},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.584827721118927},{"id":"https://openalex.org/keywords/frequency-response","display_name":"Frequency response","score":0.5415362119674683},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.4922741949558258},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.4919733703136444},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.481275737285614},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4557461738586426},{"id":"https://openalex.org/keywords/wideband","display_name":"Wideband","score":0.4465804994106293},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44437381625175476},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35613149404525757},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3273608088493347},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.16231700778007507}],"concepts":[{"id":"https://openalex.org/C37580369","wikidata":"https://www.wikidata.org/wiki/Q7655123","display_name":"Sweep frequency response analysis","level":2,"score":0.6693669557571411},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6074658036231995},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.584827721118927},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.5415362119674683},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.4922741949558258},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.4919733703136444},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.481275737285614},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4557461738586426},{"id":"https://openalex.org/C2780202535","wikidata":"https://www.wikidata.org/wiki/Q4524457","display_name":"Wideband","level":2,"score":0.4465804994106293},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44437381625175476},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35613149404525757},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3273608088493347},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.16231700778007507}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/africon55910.2023.10293538","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/africon55910.2023.10293538","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE AFRICON","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7699999809265137,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2097868428","https://openalex.org/W2131449031","https://openalex.org/W2541526644","https://openalex.org/W2767916211","https://openalex.org/W2970757488","https://openalex.org/W3097108210","https://openalex.org/W3145371344","https://openalex.org/W3202643388","https://openalex.org/W4225957058"],"related_works":["https://openalex.org/W2375985176","https://openalex.org/W2561870420","https://openalex.org/W1570623777","https://openalex.org/W1460473918","https://openalex.org/W2809479186","https://openalex.org/W2093788698","https://openalex.org/W2102216517","https://openalex.org/W2392597137","https://openalex.org/W2056788998","https://openalex.org/W2092040922"],"abstract_inverted_index":{"Frequency":[0],"response":[1,49],"analysis":[2,50],"is":[3,23,114],"a":[4,80],"popular":[5],"technique":[6],"for":[7,26],"assessing":[8],"the":[9,32,38,109,129],"mechanical":[10],"and":[11,66,90,103,131],"electrical":[12],"integrity":[13],"of":[14,31,37,51,59,73],"oil":[15],"immersed":[16],"power":[17,62],"transformers.":[18,93],"Although":[19],"this":[20,42],"diagnostic":[21],"method":[22],"often":[24],"used":[25],"transformer":[27,99,118],"condition":[28],"assessment,":[29],"interpretation":[30],"frequency":[33,48,101,111,119],"responses":[34],"remains":[35],"one":[36],"main":[39],"challenges.":[40],"In":[41],"paper,":[43],"experimental":[44],"results,":[45],"following":[46],"sweep":[47],"four":[52,85],"similar":[53],"Dy11":[54],"vector":[55],"type,":[56],"with":[57],"ratings":[58],"2.7MVA,":[60],"33kV/655V":[61],"transformers":[63,70,74,86],"are":[64,76],"presented":[65],"discussed.":[67],"The":[68,84,94],"selected":[69],"were":[71],"part":[72],"that":[75,116],"in":[77,79,128,135],"use":[78],"solar":[81],"photovoltaic":[82],"plant.":[83],"include":[87],"two":[88,91],"non-faulty":[89],"faulty":[92],"study":[95],"aims":[96],"at":[97],"explaining":[98],"wideband":[100],"characteristics":[102,120],"identifying":[104],"various":[105],"failure":[106],"modes":[107],"from":[108],"plotted":[110],"responses.":[112],"It":[113],"shown":[115],"measured":[117],"can":[121],"provide":[122],"useful":[123],"information":[124],"to":[125],"detect":[126],"defects":[127],"windings":[130],"therefore":[132],"help":[133],"greatly":[134],"maintenance.":[136]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
