{"id":"https://openalex.org/W2084178673","doi":"https://doi.org/10.1109/afrcon.2011.6071992","title":"Model based predictive control for a solar-thermal system","display_name":"Model based predictive control for a solar-thermal system","publication_year":2011,"publication_date":"2011-09-01","ids":{"openalex":"https://openalex.org/W2084178673","doi":"https://doi.org/10.1109/afrcon.2011.6071992","mag":"2084178673"},"language":"en","primary_location":{"id":"doi:10.1109/afrcon.2011.6071992","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2011.6071992","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Africon '11","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010917697","display_name":"Tarik Ferhatbegovi\u0107","orcid":null},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":true,"raw_author_name":"Tarik Ferhatbegovic","raw_affiliation_strings":["Energy Department, Austrian Institute of Technology, Vienna, Austria","[Austrian Institute of Technology, Energy Department, Vienna, Austria]"],"affiliations":[{"raw_affiliation_string":"Energy Department, Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]},{"raw_affiliation_string":"[Austrian Institute of Technology, Energy Department, Vienna, Austria]","institution_ids":["https://openalex.org/I132118926"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009655523","display_name":"Gerhard Zucker","orcid":"https://orcid.org/0000-0003-4258-2849"},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Gerhard Zucker","raw_affiliation_strings":["Energy Department, Austrian Institute of Technology, Vienna, Austria","[Austrian Institute of Technology, Energy Department, Vienna, Austria]"],"affiliations":[{"raw_affiliation_string":"Energy Department, Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]},{"raw_affiliation_string":"[Austrian Institute of Technology, Energy Department, Vienna, Austria]","institution_ids":["https://openalex.org/I132118926"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022327673","display_name":"Peter P\u00e1lensk\u00fd","orcid":"https://orcid.org/0000-0003-3183-4705"},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Peter Palensky","raw_affiliation_strings":["Energy Department, Austrian Institute of Technology, Vienna, Austria","[Austrian Institute of Technology, Energy Department, Vienna, Austria]"],"affiliations":[{"raw_affiliation_string":"Energy Department, Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]},{"raw_affiliation_string":"[Austrian Institute of Technology, Energy Department, Vienna, Austria]","institution_ids":["https://openalex.org/I132118926"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5010917697"],"corresponding_institution_ids":["https://openalex.org/I132118926"],"apc_list":null,"apc_paid":null,"fwci":6.5251,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.96397132,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11053","display_name":"Process Optimization and Integration","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.9060898423194885},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6531305909156799},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.6234803199768066},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5559694766998291},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.5336998701095581},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.526155412197113},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5259497165679932},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.5208940505981445},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5102822780609131},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.48933619260787964},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.48194432258605957},{"id":"https://openalex.org/keywords/modelica","display_name":"Modelica","score":0.4442308843135834},{"id":"https://openalex.org/keywords/solar-energy","display_name":"Solar energy","score":0.4404951333999634},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.42487382888793945},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.42100614309310913},{"id":"https://openalex.org/keywords/optimal-control","display_name":"Optimal control","score":0.415828675031662},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3834703862667084},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.38326209783554077},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3340170383453369},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.15125074982643127},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1255744993686676},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08839315176010132},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07515326142311096}],"concepts":[{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.9060898423194885},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6531305909156799},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.6234803199768066},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5559694766998291},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.5336998701095581},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.526155412197113},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5259497165679932},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.5208940505981445},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5102822780609131},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.48933619260787964},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.48194432258605957},{"id":"https://openalex.org/C37785467","wikidata":"https://www.wikidata.org/wiki/Q385325","display_name":"Modelica","level":2,"score":0.4442308843135834},{"id":"https://openalex.org/C541104983","wikidata":"https://www.wikidata.org/wiki/Q40015","display_name":"Solar energy","level":2,"score":0.4404951333999634},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.42487382888793945},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.42100614309310913},{"id":"https://openalex.org/C91575142","wikidata":"https://www.wikidata.org/wiki/Q1971426","display_name":"Optimal control","level":2,"score":0.415828675031662},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3834703862667084},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.38326209783554077},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3340170383453369},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.15125074982643127},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1255744993686676},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08839315176010132},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07515326142311096},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/afrcon.2011.6071992","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2011.6071992","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Africon '11","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1550174350","https://openalex.org/W1970181869","https://openalex.org/W1983889159","https://openalex.org/W2009921402","https://openalex.org/W2029264889","https://openalex.org/W2046992707","https://openalex.org/W2060182345","https://openalex.org/W2066704189","https://openalex.org/W2079412568","https://openalex.org/W2098882409","https://openalex.org/W2122613835","https://openalex.org/W2124608034","https://openalex.org/W2163121678","https://openalex.org/W2327732466","https://openalex.org/W2542935142","https://openalex.org/W3148779753","https://openalex.org/W4285719527","https://openalex.org/W6632936477","https://openalex.org/W6678421664","https://openalex.org/W6701848137"],"related_works":["https://openalex.org/W2326668440","https://openalex.org/W4390970874","https://openalex.org/W4240359851","https://openalex.org/W2604419375","https://openalex.org/W2296534813","https://openalex.org/W4286354644","https://openalex.org/W4200325458","https://openalex.org/W1598491185","https://openalex.org/W3033528494","https://openalex.org/W2893471340"],"abstract_inverted_index":{"Buildings":[0],"and":[1,28,32,96],"their":[2,33],"components":[3,34],"account":[4],"for":[5,30,81,127,147],"a":[6,17,55,62,75,88,93,97,108,136],"major":[7],"amount":[8],"of":[9,44,58,74,87,92,102,112,122],"the":[10,22,41,72,82,103,113,120,123,128,133,144],"overall":[11],"global":[12],"energy":[13,24,46,67,83,145],"consumption.":[14,47],"There":[15],"is":[16,35,105,141,151],"rising":[18],"demand":[19],"to":[20,39,65,118,135],"increase":[21,66],"end-use":[23],"efficiency.":[25,68],"Advanced":[26],"automation":[27,132],"control":[29,52,60,79,86,139,149],"buildings":[31],"one":[36],"possibility":[37],"how":[38],"achieve":[40],"desired":[42],"goal":[43],"lower":[45],"The":[48,100],"model":[49,76,111,124],"based":[50,77,106],"predictive":[51,78,125],"approach":[53,126,140],"as":[54],"special":[56],"form":[57],"optimal":[59],"offers":[61],"good":[63],"way":[64],"This":[69],"paper":[70],"presents":[71],"employment":[73],"algorithm":[80],"efficient":[84],"temperature":[85],"solar-thermal":[89],"system":[90,114],"consisting":[91],"solar":[94],"collector":[95],"heat":[98],"exchanger.":[99],"design":[101],"controller":[104],"upon":[107],"physical":[109],"lumped":[110],"components.":[115],"In":[116],"order":[117],"illustrate":[119],"potential":[121],"use":[129],"in":[130],"building":[131],"comparison":[134],"standard":[137],"PI":[138],"made":[142],"where":[143],"consumption":[146],"both":[148],"concepts":[150],"analyzed.":[152]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":6},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
