{"id":"https://openalex.org/W7165628187","doi":"https://doi.org/10.1109/access.2026.3706488","title":"Optimized Energy Management in V2G Systems Through SoH Aware Control Under Dynamic Pricing and Uncertain Operating Conditions","display_name":"Optimized Energy Management in V2G Systems Through SoH Aware Control Under Dynamic Pricing and Uncertain Operating Conditions","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7165628187","doi":"https://doi.org/10.1109/access.2026.3706488"},"language":"en","primary_location":{"id":"doi:10.1109/access.2026.3706488","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3706488","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2026.3706488","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048571124","display_name":"M. Poornachandra Reddy","orcid":null},"institutions":[{"id":"https://openalex.org/I876193797","display_name":"Vellore Institute of Technology University","ror":"https://ror.org/00qzypv28","country_code":"IN","type":"education","lineage":["https://openalex.org/I876193797"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"M. Poornachandra Reddy","raw_affiliation_strings":["School of Electrical Engineering, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, India"],"raw_orcid":"https://orcid.org/0000-0002-2534-9968","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, India","institution_ids":["https://openalex.org/I876193797"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5139205441","display_name":"G.K. Rajini","orcid":"https://orcid.org/0000-0002-4075-7783"},"institutions":[{"id":"https://openalex.org/I876193797","display_name":"Vellore Institute of Technology University","ror":"https://ror.org/00qzypv28","country_code":"IN","type":"education","lineage":["https://openalex.org/I876193797"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"G. K. Rajini","raw_affiliation_strings":["School of Electrical Engineering, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, India"],"raw_orcid":"https://orcid.org/0000-0002-4075-7783","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, India","institution_ids":["https://openalex.org/I876193797"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I876193797"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.71803035,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"103566","last_page":"103580"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.13750000298023224,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.13750000298023224,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.08590000122785568,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.06930000334978104,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.5235999822616577},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5220000147819519},{"id":"https://openalex.org/keywords/dynamic-pricing","display_name":"Dynamic pricing","score":0.4106999933719635},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.39500001072883606},{"id":"https://openalex.org/keywords/dynamic-programming","display_name":"Dynamic programming","score":0.38350000977516174},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.37220001220703125},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.351500004529953},{"id":"https://openalex.org/keywords/resource-management","display_name":"Resource management (computing)","score":0.3353999853134155}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7623999714851379},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5235999822616577},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5220000147819519},{"id":"https://openalex.org/C2779391423","wikidata":"https://www.wikidata.org/wiki/Q17009728","display_name":"Dynamic pricing","level":2,"score":0.4106999933719635},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.39500001072883606},{"id":"https://openalex.org/C37404715","wikidata":"https://www.wikidata.org/wiki/Q380679","display_name":"Dynamic programming","level":2,"score":0.38350000977516174},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.37220001220703125},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.351500004529953},{"id":"https://openalex.org/C2780609101","wikidata":"https://www.wikidata.org/wiki/Q17156588","display_name":"Resource management (computing)","level":2,"score":0.3353999853134155},{"id":"https://openalex.org/C91575142","wikidata":"https://www.wikidata.org/wiki/Q1971426","display_name":"Optimal control","level":2,"score":0.33309999108314514},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3068000078201294},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2996000051498413},{"id":"https://openalex.org/C79487989","wikidata":"https://www.wikidata.org/wiki/Q934680","display_name":"Vehicle dynamics","level":2,"score":0.29159998893737793},{"id":"https://openalex.org/C107568181","wikidata":"https://www.wikidata.org/wiki/Q5319000","display_name":"Dynamic priority scheduling","level":3,"score":0.2838999927043915},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.2721000015735626},{"id":"https://openalex.org/C198783460","wikidata":"https://www.wikidata.org/wiki/Q629173","display_name":"Management system","level":2,"score":0.26969999074935913},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2696000039577484},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.2605000138282776},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.2587999999523163},{"id":"https://openalex.org/C77405623","wikidata":"https://www.wikidata.org/wiki/Q598451","display_name":"System dynamics","level":2,"score":0.2583000063896179},{"id":"https://openalex.org/C106516650","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm design","level":2,"score":0.25589999556541443},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.2535000145435333},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.2535000145435333}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2026.3706488","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3706488","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:3bda05429854412c99819467d0fa09a8","is_oa":false,"landing_page_url":"https://doaj.org/article/3bda05429854412c99819467d0fa09a8","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 14, Pp 103566-103580 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2026.3706488","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3706488","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8827705383300781}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,144],"rapid":[1],"growth":[2],"in":[3],"electric":[4],"vehicle":[5],"(EV)":[6],"penetration":[7],"will":[8,17],"bring":[9],"new":[10,162],"opportunities":[11],"for":[12,72,110,203],"vehicle-to-grid":[13],"(V2G)":[14],"services":[15],"that":[16,50,148,152],"strengthen":[18],"and":[19,31,83,102,115,167,184,207],"make":[20],"the":[21,67,98,139,156,161,188,191],"grid":[22],"more":[23,205],"robust.":[24],"However,":[25],"battery":[26,63,142],"degradation,":[27],"time-of-use":[28],"electricity":[29],"prices,":[30,112],"intermittent":[32],"availability":[33],"of":[34,100,107,141,190],"renewable":[35],"energy":[36,47,165],"resources":[37],"render":[38],"V2G":[39,197],"inefficient.":[40],"This":[41],"paper":[42],"develops":[43],"a":[44,74,104,200],"state-of-health":[45],"(SoH)-sensitive":[46],"management":[48],"system":[49],"takes":[51],"into":[52,66],"account":[53],"dynamic":[54],"wholesale":[55],"price":[56,185],"signals,":[57],"solar":[58],"photovoltaic":[59],"(PV)":[60],"generation":[61],"profiles,":[62],"degradation":[64],"patterns":[65],"optimization":[68],"process.":[69],"In":[70],"planning":[71],"tomorrow,":[73],"vectorized":[75],"sample":[76],"average":[77],"approximation":[78],"(SAA)":[79],"approach":[80],"is":[81,135],"utilized":[82],"resource":[84],"opinions":[85],"to":[86,96,121,128,137,155,171],"provide":[87],"real-time":[88],"adjustments.":[89],"Monte":[90],"Carlo":[91],"(MC)":[92],"simulations":[93],"are":[94,150,153],"employed":[95,136],"estimate":[97],"level":[99],"uncertainty":[101],"generate":[103],"large":[105],"number":[106],"possible":[108,120],"outcomes":[109],"market":[111],"PV":[113,182],"production,":[114],"EV":[116,179],"availability,":[117],"making":[118],"it":[119],"test":[122],"operational":[123],"plans":[124],"with":[125],"an":[126],"eye":[127],"risk.":[129],"A":[130],"cycle-based":[131],"state-of-charge":[132],"(SoC)":[133],"model":[134,145],"calculate":[138],"cost":[140],"depletion.":[143],"ensures":[146],"certainty":[147],"decisions":[149],"made":[151],"beneficial":[154],"SoH.":[157],"Simulation":[158],"results":[159],"show":[160],"framework":[163],"reduces":[164],"consumption":[166],"degrading":[168],"impacts":[169],"compared":[170],"traditional":[172],"approaches,":[173],"but":[174],"sensitivity":[175],"tests":[176],"conducted":[177],"on":[178],"fleet":[180],"capacity,":[181,183],"volatility":[186],"confirm":[187],"robustness":[189],"approach.":[192],"Results":[193],"illustrate":[194],"SoH-aware,":[195],"uncertainty-guided":[196],"control":[198],"as":[199],"viable":[201],"solution":[202],"achieving":[204],"cost-effective":[206],"sustainable":[208],"EV-grid":[209],"integration.":[210]},"counts_by_year":[],"updated_date":"2026-07-19T07:52:34.831488","created_date":"2026-06-24T00:00:00"}
