{"id":"https://openalex.org/W7161739050","doi":"https://doi.org/10.1109/access.2026.3694676","title":"Setting-Group-Based Adaptive Zone-2 Distance Protection for Wind-Farm-Connected Transmission Lines","display_name":"Setting-Group-Based Adaptive Zone-2 Distance Protection for Wind-Farm-Connected Transmission Lines","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7161739050","doi":"https://doi.org/10.1109/access.2026.3694676"},"language":"en","primary_location":{"id":"doi:10.1109/access.2026.3694676","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3694676","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2026.3694676","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067834752","display_name":"Arash Samadi","orcid":"https://orcid.org/0000-0002-4699-7673"},"institutions":[{"id":"https://openalex.org/I48379061","display_name":"Shahid Beheshti University","ror":"https://ror.org/0091vmj44","country_code":"IR","type":"education","lineage":["https://openalex.org/I48379061"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Arash Samadi","raw_affiliation_strings":["Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran"],"raw_orcid":"https://orcid.org/0000-0002-4699-7673","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran","institution_ids":["https://openalex.org/I48379061"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5136485885","display_name":"Reza Mohammadi","orcid":"https://orcid.org/0000-0002-3211-9386"},"institutions":[{"id":"https://openalex.org/I48379061","display_name":"Shahid Beheshti University","ror":"https://ror.org/0091vmj44","country_code":"IR","type":"education","lineage":["https://openalex.org/I48379061"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Reza Mohammadi Chabanloo","raw_affiliation_strings":["Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran"],"raw_orcid":"https://orcid.org/0000-0002-3211-9386","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran","institution_ids":["https://openalex.org/I48379061"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I48379061"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.66718289,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"82439","last_page":"82453"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.4997999966144562,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.4997999966144562,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.1273999959230423,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.03869999945163727,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.6162999868392944},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.39430001378059387},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.3174000084400177},{"id":"https://openalex.org/keywords/distance-measurement","display_name":"Distance measurement","score":0.29179999232292175},{"id":"https://openalex.org/keywords/filtering-theory","display_name":"Filtering theory","score":0.2687999904155731}],"concepts":[{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.6162999868392944},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5576000213623047},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.39430001378059387},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34279999136924744},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.3174000084400177},{"id":"https://openalex.org/C2986158284","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Distance measurement","level":2,"score":0.29179999232292175},{"id":"https://openalex.org/C2988922011","wikidata":"https://www.wikidata.org/wiki/Q5449244","display_name":"Filtering theory","level":2,"score":0.2687999904155731},{"id":"https://openalex.org/C102248274","wikidata":"https://www.wikidata.org/wiki/Q168388","display_name":"Adaptive filter","level":2,"score":0.2574999928474426},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.2484000027179718},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.2370000034570694}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2026.3694676","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3694676","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:30b53a657a934090acafeaba05eb58f5","is_oa":true,"landing_page_url":"https://doaj.org/article/30b53a657a934090acafeaba05eb58f5","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 14, Pp 82439-82453 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2026.3694676","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3694676","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8381285071372986}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W980695988","https://openalex.org/W1508822367","https://openalex.org/W1904548844","https://openalex.org/W1970280758","https://openalex.org/W1980083117","https://openalex.org/W2000353133","https://openalex.org/W2051862994","https://openalex.org/W2109822621","https://openalex.org/W2114294196","https://openalex.org/W2145571599","https://openalex.org/W2345208503","https://openalex.org/W2621884934","https://openalex.org/W2737870299","https://openalex.org/W2802605568","https://openalex.org/W2958584018","https://openalex.org/W3012776736","https://openalex.org/W3016885092","https://openalex.org/W3137054743","https://openalex.org/W3153621105","https://openalex.org/W3157752100","https://openalex.org/W3182058376","https://openalex.org/W4316135844","https://openalex.org/W4387308486","https://openalex.org/W4390959470","https://openalex.org/W4401691572","https://openalex.org/W4402742663","https://openalex.org/W4403130532","https://openalex.org/W4413804728","https://openalex.org/W7160406176"],"related_works":[],"abstract_inverted_index":{"Transmission":[0],"lines":[1],"connecting":[2],"wind":[3,20],"farms":[4],"(WFs)":[5],"to":[6,17,128,140,145,159,192],"the":[7,36,90,142,169,184,198,202],"main":[8],"grid":[9],"experience":[10],"considerable":[11],"variations":[12,33],"in":[13,19,26,55],"operating":[14,109,147],"conditions":[15],"due":[16],"changes":[18],"generation":[21],"level,":[22],"number":[23],"of":[24,40,89,105,204],"units":[25],"service":[27],"(NUS),":[28],"and":[29,38,111,117,139],"network":[30,112,163],"topology.":[31],"These":[32],"significantly":[34,167,200],"challenge":[35],"dependability":[37,221],"security":[39],"conventional":[41,193],"fixed":[42],"Zone-2":[43,48,72,83,132,189,205],"distance":[44],"protection,":[45],"particularly":[46],"when":[47],"is":[49,126,157],"employed":[50],"as":[51,59],"an":[52],"overreaching":[53],"element":[54],"teleprotection":[56],"schemes":[57],"such":[58],"permissive":[60],"overreach":[61],"transfer":[62],"trip":[63],"(POTT).":[64],"This":[65],"paper":[66],"proposes":[67],"a":[68,102,153,176],"setting-group":[69],"(SG)-based":[70],"adaptive":[71],"protection":[73,99,216,220],"method":[74,186,199],"for":[75,135,214],"WF-connected":[76],"transmission":[77],"lines.":[78],"The":[79],"proposed":[80,185],"approach":[81],"maximizes":[82],"fault":[84,106],"coverage":[85,190,206],"at":[86],"both":[87],"ends":[88],"protected":[91],"line":[92],"while":[93,217],"rigorously":[94],"preserving":[95],"selectivity":[96],"with":[97],"adjacent":[98],"zones":[100],"over":[101],"wide":[103],"range":[104],"resistances,":[107],"WF":[108],"conditions,":[110],"topologies,":[113],"including":[114],"N-0,":[115],"N-1,":[116],"selected":[118],"high-impact":[119],"N-2":[120],"scenarios.":[121],"A":[122],"hybrid":[123],"optimization":[124],"framework":[125],"developed":[127],"simultaneously":[129],"determine":[130],"optimal":[131],"quadrilateral":[133],"characteristics":[134],"each":[136,146],"available":[137],"SG":[138,144],"assign":[141],"appropriate":[143],"scenario.":[148],"To":[149],"reduce":[150],"computational":[151],"burden,":[152],"systematic":[154],"scenario-reduction":[155],"technique":[156],"used":[158],"identify":[160],"only":[161],"those":[162],"elements":[164],"whose":[165],"outage":[166],"affects":[168],"relay-measured":[170],"apparent":[171],"impedance.":[172],"Simulation":[173],"results":[174],"on":[175],"modified":[177],"IEEE":[178],"39-bus":[179],"test":[180],"system":[181],"demonstrate":[182],"that":[183],"substantially":[187],"improves":[188],"compared":[191],"fixed-setting":[194],"schemes.":[195],"In":[196],"particular,":[197],"increases":[201],"overlap":[203],"between":[207],"line-end":[208],"relays,":[209],"yielding":[210],"marked":[211],"performance":[212],"gains":[213],"POTT-based":[215],"also":[218],"enhancing":[219],"under":[222],"non-teleprotected":[223],"operation.":[224]},"counts_by_year":[],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2026-05-20T00:00:00"}