{"id":"https://openalex.org/W7143435472","doi":"https://doi.org/10.1109/access.2026.3678585","title":"A Multi-Level Collaborative Voltage Optimization Method for Flexible Interconnected AC/DC Distribution Networks With High Proportion of Localized Renewable Energy Integration","display_name":"A Multi-Level Collaborative Voltage Optimization Method for Flexible Interconnected AC/DC Distribution Networks With High Proportion of Localized Renewable Energy Integration","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7143435472","doi":"https://doi.org/10.1109/access.2026.3678585"},"language":"en","primary_location":{"id":"doi:10.1109/access.2026.3678585","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3678585","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2026.3678585","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5130945571","display_name":"Fei Yang","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210094970","display_name":"Energy Research Institute","ror":"https://ror.org/00ndnb620","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094970","https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fei Yang","raw_affiliation_strings":["State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China"],"raw_orcid":"https://orcid.org/0009-0004-4227-3063","affiliations":[{"raw_affiliation_string":"State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210094970","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130916520","display_name":"Haitao Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":null,"type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haitao Liu","raw_affiliation_strings":["China Electric Power Research Institute Company Ltd., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"China Electric Power Research Institute Company Ltd., Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103070073","display_name":"Zhipeng Lv","orcid":"https://orcid.org/0000-0001-5086-9319"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210094970","display_name":"Energy Research Institute","ror":"https://ror.org/00ndnb620","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094970","https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhipeng Lv","raw_affiliation_strings":["State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210094970","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130914777","display_name":"Xiong Xiong","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210094970","display_name":"Energy Research Institute","ror":"https://ror.org/00ndnb620","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094970","https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiong Xiong","raw_affiliation_strings":["State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210094970","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101148845","display_name":"Yue Zhu","orcid":"https://orcid.org/0000-0001-5397-2290"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210094970","display_name":"Energy Research Institute","ror":"https://ror.org/00ndnb620","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094970","https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yue Zhu","raw_affiliation_strings":["State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210094970","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100459168","display_name":"Zheng Zhang","orcid":"https://orcid.org/0000-0003-1470-6998"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210094970","display_name":"Energy Research Institute","ror":"https://ror.org/00ndnb620","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094970","https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhihui Zhang","raw_affiliation_strings":["State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Shanghai Energy Internet Research Institute Company Ltd., Shanghai, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210094970","https://openalex.org/I4210126065"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5123392606","display_name":"Shuai Liang","orcid":null},"institutions":[{"id":"https://openalex.org/I37461747","display_name":"Wuhan University","ror":"https://ror.org/033vjfk17","country_code":"CN","type":"education","lineage":["https://openalex.org/I37461747"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shuai Liang","raw_affiliation_strings":["School of Electrical Engineering and Automation, Wuhan University, Wuhan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Automation, Wuhan University, Wuhan, China","institution_ids":["https://openalex.org/I37461747"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.34154139,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"62504","last_page":"62511"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.2621999979019165,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.2621999979019165,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.17730000615119934,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.13899999856948853,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.6097999811172485},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4729999899864197},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.42719998955726624},{"id":"https://openalex.org/keywords/distribution","display_name":"Distribution (mathematics)","score":0.3978999853134155},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.35359999537467957}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6656000018119812},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.6097999811172485},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4729999899864197},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.42719998955726624},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.3978999853134155},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.35359999537467957},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3411000072956085},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.25119999051094055},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24130000174045563},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.24040000140666962}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2026.3678585","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3678585","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:312e99a61c6c4ff49b7dff8abdafe689","is_oa":true,"landing_page_url":"https://doaj.org/article/312e99a61c6c4ff49b7dff8abdafe689","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 14, Pp 62504-62511 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2026.3678585","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3678585","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8535592555999756}],"awards":[{"id":"https://openalex.org/G1551029403","display_name":null,"funder_award_id":"2023YFB2407400","funder_id":"https://openalex.org/F4320335777","funder_display_name":"National Key Research and Development Program of China"}],"funders":[{"id":"https://openalex.org/F4320335777","display_name":"National Key Research and Development Program of China","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Flexible":[0],"interconnected":[1],"AC/DC":[2,129],"distribution":[3],"networks":[4],"are":[5,116],"increasingly":[6],"deployed":[7],"to":[8,53,87,119,161],"accommodate":[9],"high":[10],"penetrations":[11],"of":[12,47],"renewable":[13],"energy":[14],"sources":[15],"(RESs)":[16],"and":[17,24,29,74,91,136,152,166,172],"emerging":[18],"DC":[19,30],"loads.":[20],"Coordinated":[21],"voltage":[22,48,54,68,146],"regulation":[23],"network":[25],"reconfiguration":[26,89],"across":[27],"AC":[28],"subgrids,":[31],"however,":[32],"is":[33],"challenging":[34],"because":[35],"day-ahead":[36],"optimization":[37,69,86],"decisions":[38],"may":[39],"be":[40],"inconsistent":[41],"with":[42,71,132,148,159],"the":[43,99,120,142],"real-time":[44,103],"droop":[45],"response":[46,101],"source":[49],"converters":[50],"(VSCs),":[51],"leading":[52],"violations":[55,108,147],"or":[56],"reactive":[57],"power":[58],"shortages":[59],"after":[60],"implementation.":[61],"This":[62],"paper":[63],"proposes":[64],"a":[65,81,126],"multi-level":[66],"collaborative":[67],"framework":[70],"iterative":[72],"feedback":[73],"consistency":[75,113],"constraints.":[76],"The":[77,95],"system":[78,131],"layer":[79,97],"solves":[80],"scenario-based":[82],"stochastic":[83],"mixed-integer":[84],"convex":[85],"determine":[88],"states":[90],"VSC":[92,138,164],"reference":[93],"commands.":[94],"device":[96],"evaluates":[98],"closed-loop":[100],"under":[102],"RES":[104,162],"realizations":[105],"and,":[106],"whenever":[107],"occur,":[109],"generates":[110],"sensitivity-based":[111],"linear":[112],"cuts":[114],"that":[115,141],"iteratively":[117],"appended":[118],"system-layer":[121],"optimization.":[122],"Case":[123],"studies":[124,158],"on":[125],"51-bus":[127],"hybrid":[128],"test":[130],"four":[133],"reconfigurable":[134],"switches":[135],"three":[137],"links":[139],"demonstrate":[140],"proposed":[143],"method":[144],"eliminates":[145],"limited":[149],"operating":[150],"cost":[151],"maintains":[153],"practical":[154],"computational":[155],"performance.":[156],"Sensitivity":[157],"respect":[160],"penetration,":[163],"capacity,":[165],"scenario":[167],"number":[168],"further":[169],"validate":[170],"robustness":[171],"scalability.":[173]},"counts_by_year":[],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2026-03-31T00:00:00"}
