{"id":"https://openalex.org/W7135200374","doi":"https://doi.org/10.1109/access.2026.3674053","title":"Online Charge Balancing With Active Impedance Monitoring in Programmable Stimulator to Extend Electrode Lifetime","display_name":"Online Charge Balancing With Active Impedance Monitoring in Programmable Stimulator to Extend Electrode Lifetime","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7135200374","doi":"https://doi.org/10.1109/access.2026.3674053","pmid":"https://pubmed.ncbi.nlm.nih.gov/42005467"},"language":"en","primary_location":{"id":"doi:10.1109/access.2026.3674053","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3674053","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2026.3674053","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021633420","display_name":"K W Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kangni Liu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":"https://orcid.org/0009-0001-9451-9043","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5129039923","display_name":"Guangzong Chen","orcid":null},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Guangzong Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":"https://orcid.org/0009-0007-7831-2273","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089332805","display_name":"Kevin M. Woeppel","orcid":null},"institutions":[{"id":"https://openalex.org/I4210135492","display_name":"Cognition Therapeutics (United States)","ror":"https://ror.org/03z2xqc96","country_code":"US","type":"company","lineage":["https://openalex.org/I4210135492"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kevin Woeppel","raw_affiliation_strings":["Vanish Therapeutics, Pittsburgh, PA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Vanish Therapeutics, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I4210135492"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051492786","display_name":"X. Tracy Cui","orcid":null},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"X. Tracy Cui","raw_affiliation_strings":["Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5055741874","display_name":"Rajkumar Kubendran","orcid":"https://orcid.org/0000-0003-3066-4898"},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Rajkumar Kubendran","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":"https://orcid.org/0000-0003-3066-4898","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.25160505,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"45558","last_page":"45570"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.17000000178813934,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.17000000178813934,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.14390000700950623,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.07419999688863754,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.6165000200271606},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6049000024795532},{"id":"https://openalex.org/keywords/focused-impedance-measurement","display_name":"Focused Impedance Measurement","score":0.4839000105857849},{"id":"https://openalex.org/keywords/charge","display_name":"Charge (physics)","score":0.40070000290870667},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3012000024318695},{"id":"https://openalex.org/keywords/electrostatic-discharge","display_name":"Electrostatic discharge","score":0.28700000047683716}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6305000185966492},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.6165000200271606},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6049000024795532},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.5835000276565552},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.4839000105857849},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4787999987602234},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4050000011920929},{"id":"https://openalex.org/C188082385","wikidata":"https://www.wikidata.org/wiki/Q73792","display_name":"Charge (physics)","level":2,"score":0.40070000290870667},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3222000002861023},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3012000024318695},{"id":"https://openalex.org/C205483674","wikidata":"https://www.wikidata.org/wiki/Q3574961","display_name":"Electrostatic discharge","level":3,"score":0.28700000047683716},{"id":"https://openalex.org/C612350","wikidata":"https://www.wikidata.org/wiki/Q1761108","display_name":"Impedance matching","level":3,"score":0.2800000011920929},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.27469998598098755},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.26420000195503235},{"id":"https://openalex.org/C26262908","wikidata":"https://www.wikidata.org/wiki/Q1307489","display_name":"Input impedance","level":3,"score":0.263700008392334},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.26269999146461487},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.26080000400543213}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1109/access.2026.3674053","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3674053","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmid:42005467","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/42005467","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE access : practical innovations, open solutions","raw_type":null},{"id":"pmh:oai:doaj.org/article:70a7a3cfcaac454aa49d24738aeac662","is_oa":true,"landing_page_url":"https://doaj.org/article/70a7a3cfcaac454aa49d24738aeac662","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 14, Pp 45558-45570 (2026)","raw_type":"article"},{"id":"pmh:oai:pubmedcentral.nih.gov:13089616","is_oa":true,"landing_page_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13089616/","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.1109/access.2026.3674053","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3674053","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7664316892623901}],"awards":[{"id":"https://openalex.org/G6032963153","display_name":null,"funder_award_id":"R41NS132625","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"}],"funders":[{"id":"https://openalex.org/F4320323110","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74"},{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Neurostimulation":[0],"therapies":[1],"are":[2],"often":[3],"applied":[4],"as":[5],"an":[6,145],"alternative":[7],"method":[8],"to":[9,56,73,82,92,111,202,241],"pharmaceutical":[10],"treatment":[11],"for":[12,20,215],"pain":[13],"relief.This":[14],"paper":[15],"demonstrates":[16],"a":[17,43,189],"programmable":[18,208],"stimulator":[19,39],"analgesic":[21],"nerve":[22],"stimulation":[23,86,149,196,209,236],"through":[24],"invasive":[25],"electrodes.":[26],"It":[27],"provides":[28],"two":[29],"modes":[30],"of":[31,63,131,195,233],"operation:":[32],"constant-current":[33],"biphasic":[34],"and":[35,52,85,127,185],"capacitor-coupled":[36],"biphasic.":[37],"The":[38,122,225],"is":[40,71],"integrated":[41],"on":[42,177],"50":[44],"x":[45],"30":[46,120],"mm":[47],"Printed":[48],"Circuit":[49],"Board":[50],"(PCB)":[51],"can":[53],"generate":[54],"up":[55],"\u00b11.6":[57],"mA":[58],"current":[59,150],"pulses":[60,221],"in":[61,101,222,226],"steps":[62],"6.3":[64],"\u03bcA.":[65],"A":[66,172],"custom":[67],"STM32":[68,179],"microcontroller":[69,180],"library":[70],"used":[72],"tune":[74],"the":[75,102,105,132,139,162,166,178,183,206,212,231,239],"pulse":[76],"duration":[77],"range":[78,88],"from":[79,108,138],"1":[80,109],"\u03bcs":[81],"10":[83,112],"s":[84],"frequency":[87,106,140],"between":[89],"0.1":[90],"Hz":[91,110],"100":[93],"kHz.":[94],"An":[95],"Active":[96],"Impedance":[97],"Monitoring":[98],"(AIM)":[99],"unit":[100],"PCB":[103,163],"measures":[104],"response":[107,141],"kHz":[113],"with":[114,157,169,247],"8":[115],"samples":[116],"per":[117],"decade":[118],"every":[119],"minutes.":[121],"electrode":[123,213],"resistance,":[124],"tissue":[125],"resistance":[126],"RC":[128,159],"time":[129],"constant":[130],"electrode-tissue":[133],"system":[134,210],"could":[135,164,181],"be":[136],"calculated":[137],"curve,":[142],"generated":[143],"by":[144],"input":[146],"square":[147],"wave":[148],"at":[151],"different":[152,155],"frequencies.":[153],"In":[154],"measurements":[156],"discrete":[158],"circuit":[160],"components,":[161],"calculate":[165],"impedance":[167,200],"values":[168],">90%":[170],"precision.":[171],"novel":[173],"charge-balancing":[174],"algorithm":[175],"implemented":[176],"match":[182],"positive":[184],"negative":[186],"charge":[187,204,234],"within":[188],"5%":[190],"error.":[191],"Through":[192],"online":[193],"adjustment":[194],"parameters":[197],"using":[198],"active":[199],"monitoring":[201],"achieve":[203],"balancing,":[205],"proposed":[207],"extends":[211],"lifetime":[214],"more":[216],"than":[217],"288":[218],"million":[219],"continuous":[220],"vitro":[223,227],"studies.":[224],"studies":[228],"clearly":[229],"demonstrated":[230],"efficacy":[232],"balanced":[235],"that":[237],"enable":[238],"electrodes":[240],"last":[242],"around":[243],"3":[244],"times":[245],"longer":[246],"negligible":[248],"degradation.":[249]},"counts_by_year":[],"updated_date":"2026-03-28T06:11:35.319607","created_date":"2026-03-14T00:00:00"}
