{"id":"https://openalex.org/W7123358693","doi":"https://doi.org/10.1109/access.2026.3652919","title":"Investigation on the Thermal Characteristics of 33-kV DC Vacuum Circuit Breakers Using 3-D Modeling","display_name":"Investigation on the Thermal Characteristics of 33-kV DC Vacuum Circuit Breakers Using 3-D Modeling","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7123358693","doi":"https://doi.org/10.1109/access.2026.3652919"},"language":"en","primary_location":{"id":"doi:10.1109/access.2026.3652919","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3652919","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2026.3652919","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5065866960","display_name":"Osama E. Gouda","orcid":"https://orcid.org/0000-0002-7092-8387"},"institutions":[{"id":"https://openalex.org/I145487455","display_name":"Cairo University","ror":"https://ror.org/03q21mh05","country_code":"EG","type":"education","lineage":["https://openalex.org/I145487455"]}],"countries":["EG"],"is_corresponding":true,"raw_author_name":"Ossama E. Gouda","raw_affiliation_strings":["Department of Electrical Power Engineering, Faculty of Engineering, Cairo University, Giza, Egypt"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Power Engineering, Faculty of Engineering, Cairo University, Giza, Egypt","institution_ids":["https://openalex.org/I145487455"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5122851397","display_name":"Ahmed Hamdy Elsersy","orcid":null},"institutions":[{"id":"https://openalex.org/I88126159","display_name":"Egyptian Petroleum Research Institute","ror":"https://ror.org/044panr52","country_code":"EG","type":"facility","lineage":["https://openalex.org/I88126159"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Ahmed Hamdy Elsersy","raw_affiliation_strings":["Engineering for the Petroleum and Process Industries (ENPPI) Company, Cairo, Egypt"],"affiliations":[{"raw_affiliation_string":"Engineering for the Petroleum and Process Industries (ENPPI) Company, Cairo, Egypt","institution_ids":["https://openalex.org/I88126159"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5106408254","display_name":"Matti I. Lehtonen","orcid":null},"institutions":[{"id":"https://openalex.org/I9927081","display_name":"Aalto University","ror":"https://ror.org/020hwjq30","country_code":"FI","type":"education","lineage":["https://openalex.org/I9927081"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Matti Lehtonen","raw_affiliation_strings":["Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, Espoo, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, Espoo, Finland","institution_ids":["https://openalex.org/I9927081"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5114015205","display_name":"Mahmoud Darwish","orcid":null},"institutions":[{"id":"https://openalex.org/I207547235","display_name":"Benha University","ror":"https://ror.org/03tn5ee41","country_code":"EG","type":"education","lineage":["https://openalex.org/I207547235"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Mohamed M. F. Darwish","raw_affiliation_strings":["Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt","institution_ids":["https://openalex.org/I207547235"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5065866960"],"corresponding_institution_ids":["https://openalex.org/I145487455"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.17959796,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"9124","last_page":"9138"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5396000146865845,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5396000146865845,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12077","display_name":"Vacuum and Plasma Arcs","score":0.3546999990940094,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.020999999716877937,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/contact-resistance","display_name":"Contact resistance","score":0.7825000286102295},{"id":"https://openalex.org/keywords/thermal-contact-conductance","display_name":"Thermal contact conductance","score":0.7135999798774719},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.5928000211715698},{"id":"https://openalex.org/keywords/thermal-resistance","display_name":"Thermal resistance","score":0.5719000101089478},{"id":"https://openalex.org/keywords/electrical-contacts","display_name":"Electrical contacts","score":0.5504000186920166},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.48429998755455017},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.4652000069618225},{"id":"https://openalex.org/keywords/thermal-contact","display_name":"Thermal contact","score":0.44029998779296875}],"concepts":[{"id":"https://openalex.org/C123671423","wikidata":"https://www.wikidata.org/wiki/Q332329","display_name":"Contact resistance","level":3,"score":0.7825000286102295},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.781000018119812},{"id":"https://openalex.org/C45058047","wikidata":"https://www.wikidata.org/wiki/Q4119687","display_name":"Thermal contact conductance","level":4,"score":0.7135999798774719},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5928000211715698},{"id":"https://openalex.org/C137693562","wikidata":"https://www.wikidata.org/wiki/Q899628","display_name":"Thermal resistance","level":3,"score":0.5719000101089478},{"id":"https://openalex.org/C132235601","wikidata":"https://www.wikidata.org/wiki/Q394001","display_name":"Electrical contacts","level":2,"score":0.5504000186920166},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.48429998755455017},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.4652000069618225},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.44200000166893005},{"id":"https://openalex.org/C142014798","wikidata":"https://www.wikidata.org/wiki/Q7783037","display_name":"Thermal contact","level":3,"score":0.44029998779296875},{"id":"https://openalex.org/C131321042","wikidata":"https://www.wikidata.org/wiki/Q656685","display_name":"Operating temperature","level":2,"score":0.41609999537467957},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.39250001311302185},{"id":"https://openalex.org/C33373654","wikidata":"https://www.wikidata.org/wiki/Q5164821","display_name":"Contact area","level":2,"score":0.373199999332428},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.33820000290870667},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3310999870300293},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.3257000148296356},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3181000053882599},{"id":"https://openalex.org/C94857076","wikidata":"https://www.wikidata.org/wiki/Q106603432","display_name":"Electrical resistance and conductance","level":2,"score":0.3109999895095825},{"id":"https://openalex.org/C2993791989","wikidata":"https://www.wikidata.org/wiki/Q917476","display_name":"Inverse temperature","level":2,"score":0.3052999973297119},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.30489999055862427},{"id":"https://openalex.org/C167781694","wikidata":"https://www.wikidata.org/wiki/Q6311800","display_name":"Junction temperature","level":3,"score":0.3019999861717224},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.2872999906539917},{"id":"https://openalex.org/C2985831756","wikidata":"https://www.wikidata.org/wiki/Q107291880","display_name":"Maximum temperature","level":2,"score":0.2818000018596649},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.25600001215934753},{"id":"https://openalex.org/C97346530","wikidata":"https://www.wikidata.org/wiki/Q487005","display_name":"Thermal conductivity","level":2,"score":0.2554999887943268}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2026.3652919","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3652919","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:aaltodoc.aalto.fi:123456789/142790","is_oa":true,"landing_page_url":"https://doi.org/10.1109/ACCESS.2026.3652919","pdf_url":null,"source":{"id":"https://openalex.org/S4306401663","display_name":"Aaltodoc (Aalto University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I9927081","host_organization_name":"Aalto University","host_organization_lineage":["https://openalex.org/I9927081"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":null,"raw_type":"publishedVersion"}],"best_oa_location":{"id":"doi:10.1109/access.2026.3652919","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2026.3652919","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5620384812355042}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W2019389157","https://openalex.org/W2035279426","https://openalex.org/W2069543649","https://openalex.org/W2072716345","https://openalex.org/W2199538606","https://openalex.org/W2416291739","https://openalex.org/W2507242331","https://openalex.org/W2529860214","https://openalex.org/W2552114966","https://openalex.org/W2566588025","https://openalex.org/W2566673874","https://openalex.org/W2592205226","https://openalex.org/W2606276573","https://openalex.org/W2786066807","https://openalex.org/W2893321780","https://openalex.org/W2922236397","https://openalex.org/W2955992516","https://openalex.org/W2970808264","https://openalex.org/W3035580908","https://openalex.org/W3040835120","https://openalex.org/W3120797789","https://openalex.org/W3127911101","https://openalex.org/W3189863092","https://openalex.org/W4200620275","https://openalex.org/W4256623212","https://openalex.org/W4315630670","https://openalex.org/W4320168320","https://openalex.org/W4385662392","https://openalex.org/W4385668487","https://openalex.org/W4403111077","https://openalex.org/W4410428933","https://openalex.org/W4412098745","https://openalex.org/W4414404602"],"related_works":[],"abstract_inverted_index":{"In":[0,84],"this":[1,35],"article,":[2],"a":[3,44,69,138,189],"3D":[4,38],"model":[5,45],"is":[6,41,46,64,95,120,130,154,206],"used":[7],"to":[8,112,165,188,208],"investigate":[9],"the":[10,14,37,58,82,86,92,116,123,127,133,149,160,170,177,181,196,200,215,219,222],"thermal":[11,76,210],"performance":[12,220],"of":[13,51,62,81,88,115,135,199,221],"33":[15],"kV":[16],"Direct":[17],"Current":[18],"Vacuum":[19],"Circuit":[20],"Breakers":[21],"(DCVCBs)":[22],"when":[23],"operating":[24],"under":[25,31],"normal":[26],"current":[27],"as":[28,30],"well":[29],"faulty":[32,158],"conditions.":[33],"For":[34],"purpose,":[36],"COMSOL":[39],"program":[40],"employed,":[42],"and":[43,54,78,105,144,217],"built":[47],"inside.":[48],"The":[49,66],"impact":[50],"contact":[52,55,89,150,171,182,185,204],"materials":[53],"resistance":[56,90,186,205],"on":[57,91,148,169],"maximum":[59],"temperature":[60,79,93,139,161,178,191],"rise":[61,80,94,140,179],"DCVCB":[63],"investigated.":[65],"results":[67,125],"demonstrate":[68],"clear":[70],"inverse":[71],"relationship":[72],"between":[73,141],"electrical":[74],"conductivity,":[75,77],"DCVCBs.":[83],"addition,":[85],"influence":[87],"discussed.":[96],"These":[97],"alloy":[98],"materials,":[99],"namely,":[100],"Tungsten-Copper":[101],"(WCu),":[102],"Copper-Chromium":[103],"(CuCr),":[104],"Oxygen-Free":[106],"Electronic":[107],"(OFE":[108],"Copper),":[109],"are":[110],"selected":[111],"be":[113],"contacts":[114,134,198],"vacuum":[117],"interrupter.":[118],"It":[119,153],"observed":[121],"from":[122],"simulation":[124],"that":[126],"hot":[128],"spot":[129],"formed":[131],"in":[132],"DCVCBs":[136],"with":[137],"51":[142],"\u00b0C":[143,164,167],"29":[145],"\u00b0C,":[146],"depending":[147,168],"material":[151,197],"conductivity.":[152],"found":[155],"that,":[156],"at":[157,180,214],"condition,":[159],"reached":[162],"1350":[163],"4400":[166],"material.":[172],"Contact":[173],"resistances":[174],"directly":[175],"affect":[176],"interfaces.":[183],"Increased":[184],"leads":[187],"higher":[190],"rise,":[192],"which":[193],"could":[194],"degrade":[195],"DCVCB.":[201],"Therefore,":[202],"minimizing":[203],"essential":[207],"enhance":[209],"stability,":[211],"reduce":[212],"heating":[213],"contacts,":[216],"improve":[218],"circuit":[223],"breaker.":[224]},"counts_by_year":[],"updated_date":"2026-01-24T23:23:39.755997","created_date":"2026-01-14T00:00:00"}
