{"id":"https://openalex.org/W7117555614","doi":"https://doi.org/10.1109/access.2025.3649693","title":"Determine the Exact Fault Location in Underground Cable: A Systematic Review","display_name":"Determine the Exact Fault Location in Underground Cable: A Systematic Review","publication_year":2025,"publication_date":"2025-12-30","ids":{"openalex":"https://openalex.org/W7117555614","doi":"https://doi.org/10.1109/access.2025.3649693"},"language":null,"primary_location":{"id":"doi:10.1109/access.2025.3649693","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3649693","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3649693","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024698053","display_name":"S. Sudhagar","orcid":null},"institutions":[{"id":"https://openalex.org/I876193797","display_name":"Vellore Institute of Technology University","ror":"https://ror.org/00qzypv28","country_code":"IN","type":"education","lineage":["https://openalex.org/I876193797"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"S. Sudhagar","raw_affiliation_strings":["School of Electrical Engineering, Vellore Institute of Technology, Vellore, India"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Vellore Institute of Technology, Vellore, India","institution_ids":["https://openalex.org/I876193797"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038606897","display_name":"R. Marimuthu","orcid":null},"institutions":[{"id":"https://openalex.org/I876193797","display_name":"Vellore Institute of Technology University","ror":"https://ror.org/00qzypv28","country_code":"IN","type":"education","lineage":["https://openalex.org/I876193797"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"R. Marimuthu","raw_affiliation_strings":["School of Electrical Engineering, Vellore Institute of Technology, Vellore, India"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Vellore Institute of Technology, Vellore, India","institution_ids":["https://openalex.org/I876193797"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5024698053"],"corresponding_institution_ids":["https://openalex.org/I876193797"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.65484192,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":null,"first_page":"1135","last_page":"1151"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.3449000120162964,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.3449000120162964,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.20800000429153442,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.2021999955177307,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6870999932289124},{"id":"https://openalex.org/keywords/power-cable","display_name":"Power cable","score":0.6532999873161316},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.47540000081062317},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.41830000281333923},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4000999927520752},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.39430001378059387},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.35600000619888306}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6870999932289124},{"id":"https://openalex.org/C2777772068","wikidata":"https://www.wikidata.org/wiki/Q1939150","display_name":"Power cable","level":3,"score":0.6532999873161316},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.47540000081062317},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45910000801086426},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41830000281333923},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4034999907016754},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4000999927520752},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.39430001378059387},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.35600000619888306},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.33880001306533813},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.33239999413490295},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.32989999651908875},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.32440000772476196},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27480000257492065},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.2703999876976013},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.26829999685287476},{"id":"https://openalex.org/C114375839","wikidata":"https://www.wikidata.org/wiki/Q207456","display_name":"Electric arc","level":3,"score":0.2662999927997589},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.2662000060081482},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.26499998569488525}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/access.2025.3649693","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3649693","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3649693","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3649693","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Sustainable cities and communities","score":0.5734880566596985,"id":"https://metadata.un.org/sdg/11"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":134,"referenced_works":["https://openalex.org/W80559089","https://openalex.org/W1556244765","https://openalex.org/W1910407586","https://openalex.org/W1963840644","https://openalex.org/W1970083423","https://openalex.org/W1976230056","https://openalex.org/W1985695480","https://openalex.org/W1985945493","https://openalex.org/W2003954000","https://openalex.org/W2008958182","https://openalex.org/W2018924514","https://openalex.org/W2030889202","https://openalex.org/W2033473827","https://openalex.org/W2037744170","https://openalex.org/W2040053173","https://openalex.org/W2041875219","https://openalex.org/W2047085264","https://openalex.org/W2054512998","https://openalex.org/W2068467213","https://openalex.org/W2078873603","https://openalex.org/W2084011088","https://openalex.org/W2085128774","https://openalex.org/W2094371357","https://openalex.org/W2095736798","https://openalex.org/W2100903621","https://openalex.org/W2109711869","https://openalex.org/W2111015730","https://openalex.org/W2115662708","https://openalex.org/W2117171612","https://openalex.org/W2117962465","https://openalex.org/W2118288847","https://openalex.org/W2120235526","https://openalex.org/W2120907414","https://openalex.org/W2124408286","https://openalex.org/W2129292867","https://openalex.org/W2146853200","https://openalex.org/W2149033685","https://openalex.org/W2149689170","https://openalex.org/W2152187883","https://openalex.org/W2152779354","https://openalex.org/W2154291887","https://openalex.org/W2158393159","https://openalex.org/W2159094357","https://openalex.org/W2163459401","https://openalex.org/W2170514380","https://openalex.org/W2274974792","https://openalex.org/W2313946831","https://openalex.org/W2337881469","https://openalex.org/W2343960848","https://openalex.org/W2398216368","https://openalex.org/W2400913203","https://openalex.org/W2466968898","https://openalex.org/W2501682360","https://openalex.org/W2509888784","https://openalex.org/W2525979889","https://openalex.org/W2531562075","https://openalex.org/W2543397915","https://openalex.org/W2565163865","https://openalex.org/W2587878334","https://openalex.org/W2591801159","https://openalex.org/W2621397563","https://openalex.org/W2765368879","https://openalex.org/W2779464896","https://openalex.org/W2901475400","https://openalex.org/W2931000505","https://openalex.org/W2942523767","https://openalex.org/W2969511105","https://openalex.org/W2996291934","https://openalex.org/W2999906327","https://openalex.org/W3007548312","https://openalex.org/W3016541735","https://openalex.org/W3019930021","https://openalex.org/W3020912405","https://openalex.org/W3045581851","https://openalex.org/W3091000802","https://openalex.org/W3091738834","https://openalex.org/W3096319971","https://openalex.org/W3112170024","https://openalex.org/W3113197517","https://openalex.org/W3144811017","https://openalex.org/W3146284778","https://openalex.org/W3167067315","https://openalex.org/W3170738157","https://openalex.org/W3184571638","https://openalex.org/W3185433366","https://openalex.org/W3194580270","https://openalex.org/W3203868719","https://openalex.org/W4205876086","https://openalex.org/W4206212046","https://openalex.org/W4213325338","https://openalex.org/W4220702386","https://openalex.org/W4231063918","https://openalex.org/W4234945768","https://openalex.org/W4241192311","https://openalex.org/W4252072684","https://openalex.org/W4253861900","https://openalex.org/W4280627715","https://openalex.org/W4285122660","https://openalex.org/W4290043189","https://openalex.org/W4290043452","https://openalex.org/W4294833770","https://openalex.org/W4299615733","https://openalex.org/W4308390379","https://openalex.org/W4313252005","https://openalex.org/W4313253689","https://openalex.org/W4322154829","https://openalex.org/W4380483881","https://openalex.org/W4388913522","https://openalex.org/W4390605654","https://openalex.org/W4392114397","https://openalex.org/W4397034218","https://openalex.org/W4398160854","https://openalex.org/W4399172058","https://openalex.org/W4399801309","https://openalex.org/W4399881333","https://openalex.org/W4400033210","https://openalex.org/W4401567510","https://openalex.org/W4402236662","https://openalex.org/W4402827029","https://openalex.org/W4403279360","https://openalex.org/W4404031728","https://openalex.org/W4405189337","https://openalex.org/W4405839336","https://openalex.org/W4405899685","https://openalex.org/W4405941716","https://openalex.org/W4406145967","https://openalex.org/W4406806343","https://openalex.org/W4407128693","https://openalex.org/W4407193747","https://openalex.org/W4408215418","https://openalex.org/W4408565514","https://openalex.org/W4410386868","https://openalex.org/W4411980155","https://openalex.org/W4412189581"],"related_works":[],"abstract_inverted_index":{"In":[0,35],"urban":[1],"areas,":[2],"the":[3,37,41,65,71,133,136],"power":[4],"distribution":[5],"system":[6],"is":[7,23,76],"based":[8],"on":[9,40],"medium-voltage":[10],"energy":[11],"cables.":[12],"Typically,":[13],"place":[14],"cables":[15,22],"underground":[16,74],"in":[17,21,52,70],"urban;":[18],"finding":[19],"faults":[20],"very":[24],"challenging.":[25],"This":[26,94,110],"paper":[27,38],"reviews":[28],"several":[29],"fault":[30,103,116,121],"detections":[31],"and":[32,63,68,98,108,127,129],"location":[33,122],"identifications.":[34],"addition,":[36],"relies":[39],"study":[42],"of":[43,120,123,135],"cable.":[44],"Existing":[45],"published":[46],"articles":[47],"play":[48],"a":[49],"vital":[50],"role":[51],"trying":[53],"to":[54,87,96,106],"target":[55],"cable":[56,59,66,75,90,113],"durability,":[57],"reliability,":[58],"modeling,":[60,114],"protection":[61],"relay,":[62],"monitoring":[64],"voltage":[67],"current":[69],"substation.":[72],"The":[73,101],"not":[77],"affected":[78],"by":[79],"thunder,":[80],"climate":[81],"change,":[82],"rain,":[83],"or":[84],"snow.":[85],"Due":[86],"aging":[88],"effects,":[89],"sheathing":[91],"can":[92],"occur.":[93],"leads":[95],"incipient":[97],"arcing":[99],"faults.":[100],"possible":[102],"will":[104],"fail":[105],"open":[107],"short-circuit.":[109],"survey":[111],"explains":[112],"faults,":[115],"detection":[117],"techniques,":[118],"estimates":[119],"various":[124],"trees,":[125],"protection,":[126],"electrical":[128],"water":[130],"trees.":[131],"Finally,":[132],"results":[134],"stimulation":[137],"metrics":[138],"are":[139],"displayed.":[140]},"counts_by_year":[],"updated_date":"2026-01-08T20:05:33.558190","created_date":"2025-12-30T00:00:00"}
