{"id":"https://openalex.org/W4417002440","doi":"https://doi.org/10.1109/access.2025.3640549","title":"Common-Ground Boosting Compact Multilevel Inverter Topology for Solar PV Applications","display_name":"Common-Ground Boosting Compact Multilevel Inverter Topology for Solar PV Applications","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4417002440","doi":"https://doi.org/10.1109/access.2025.3640549"},"language":null,"primary_location":{"id":"doi:10.1109/access.2025.3640549","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3640549","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3640549","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077420836","display_name":"Kaibalya Prasad Panda","orcid":"https://orcid.org/0000-0001-7486-6139"},"institutions":[{"id":"https://openalex.org/I33586908","display_name":"Pandit Deendayal Energy University","ror":"https://ror.org/02nsv5p42","country_code":"IN","type":"education","lineage":["https://openalex.org/I33586908"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Kaibalya Prasad Panda","raw_affiliation_strings":["Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India"],"raw_orcid":"https://orcid.org/0000-0001-7486-6139","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India","institution_ids":["https://openalex.org/I33586908"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018863646","display_name":"Sumant Kumar Dalai","orcid":"https://orcid.org/0000-0002-5793-6403"},"institutions":[{"id":"https://openalex.org/I4028839","display_name":"Biju Patnaik University of Technology","ror":"https://ror.org/03vqjtg68","country_code":"IN","type":"education","lineage":["https://openalex.org/I4028839"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sumant Kumar Dalai","raw_affiliation_strings":["Department of Electrical Engineering, Centre for Undergraduate &#x0026; Postgraduate Studies, Biju Patnaik University of Technology, Rourkela, Odisha, India","Department of Electrical Engineering, Centre for UG &#x0026; PG, Biju Patnaik University of Technology Rourkela, Odisha, India"],"raw_orcid":"https://orcid.org/0000-0002-5793-6403","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Centre for Undergraduate &#x0026; Postgraduate Studies, Biju Patnaik University of Technology, Rourkela, Odisha, India","institution_ids":["https://openalex.org/I4028839"]},{"raw_affiliation_string":"Department of Electrical Engineering, Centre for UG &#x0026; PG, Biju Patnaik University of Technology Rourkela, Odisha, India","institution_ids":["https://openalex.org/I4028839"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064119644","display_name":"Rishika Sharma","orcid":null},"institutions":[{"id":"https://openalex.org/I33586908","display_name":"Pandit Deendayal Energy University","ror":"https://ror.org/02nsv5p42","country_code":"IN","type":"education","lineage":["https://openalex.org/I33586908"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rishika Sharma","raw_affiliation_strings":["Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India","institution_ids":["https://openalex.org/I33586908"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Shree Solanki","orcid":null},"institutions":[{"id":"https://openalex.org/I33586908","display_name":"Pandit Deendayal Energy University","ror":"https://ror.org/02nsv5p42","country_code":"IN","type":"education","lineage":["https://openalex.org/I33586908"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shree Solanki","raw_affiliation_strings":["Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, School of Energy Technology, Pandit Deendayal Energy University (PDEU), Gandhinagar, Gujarat, India","institution_ids":["https://openalex.org/I33586908"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058369056","display_name":"Gayadhar Panda","orcid":"https://orcid.org/0000-0002-0156-3134"},"institutions":[{"id":"https://openalex.org/I4210094264","display_name":"National Institute of Technical Teachers\u2019 Training and Research","ror":"https://ror.org/00k8f0f41","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210094264"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Gayadhar Panda","raw_affiliation_strings":["Department of Electrical Engineering, National Institute of Technical Teachers&#x2019; Training and Research Kolkata, Kolkata, India","Department of Electrical Engineering, National Institute of Technical Teachers&#x2019; Training and Research, Kolkata, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Institute of Technical Teachers&#x2019; Training and Research Kolkata, Kolkata, India","institution_ids":["https://openalex.org/I4210094264"]},{"raw_affiliation_string":"Department of Electrical Engineering, National Institute of Technical Teachers&#x2019; Training and Research, Kolkata, India","institution_ids":["https://openalex.org/I4210094264"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.32098619,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"13","issue":null,"first_page":"206198","last_page":"206210"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9790999889373779,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9790999889373779,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.007899999618530273,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.0034000000450760126,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.7509999871253967},{"id":"https://openalex.org/keywords/boosting","display_name":"Boosting (machine learning)","score":0.5699999928474426},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.5077000260353088},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5041999816894531},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4887000024318695},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.42160001397132874},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.40450000762939453},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.3885999917984009}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7509999871253967},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.609499990940094},{"id":"https://openalex.org/C46686674","wikidata":"https://www.wikidata.org/wiki/Q466303","display_name":"Boosting (machine learning)","level":2,"score":0.5699999928474426},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.5077000260353088},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5041999816894531},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4964999854564667},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4887000024318695},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.42160001397132874},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.40450000762939453},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.3885999917984009},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.38530001044273376},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32710000872612},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.3061999976634979},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.29670000076293945},{"id":"https://openalex.org/C53954817","wikidata":"https://www.wikidata.org/wiki/Q7556716","display_name":"Solar micro-inverter","level":5,"score":0.287200003862381},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.2858000099658966},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.28049999475479126},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.2784000039100647},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2768999934196472},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.27649998664855957},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2687000036239624},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.25519999861717224},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.25110000371932983},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.2506999969482422}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/access.2025.3640549","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3640549","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3640549","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3640549","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W1988689872","https://openalex.org/W2001262230","https://openalex.org/W2322232835","https://openalex.org/W2588489920","https://openalex.org/W2592517717","https://openalex.org/W2809286319","https://openalex.org/W2896738506","https://openalex.org/W2905044865","https://openalex.org/W2914266407","https://openalex.org/W2921724219","https://openalex.org/W2943643689","https://openalex.org/W2968812074","https://openalex.org/W2983896061","https://openalex.org/W2985890475","https://openalex.org/W3013649962","https://openalex.org/W3035758070","https://openalex.org/W3139246401","https://openalex.org/W3194992283","https://openalex.org/W3214927078","https://openalex.org/W4205681158","https://openalex.org/W4289783331","https://openalex.org/W4312600697","https://openalex.org/W4385194694","https://openalex.org/W4385819597","https://openalex.org/W4389451089","https://openalex.org/W4392114267","https://openalex.org/W4392207771","https://openalex.org/W4392207903"],"related_works":[],"abstract_inverted_index":{"Modular":[0],"and":[1,26,75,138,157,163,171],"Transformerless":[2],"multilevel":[3],"inverters":[4],"(MLIs)":[5],"have":[6],"become":[7],"a":[8,40,54,89],"crucial":[9],"interface":[10],"technology":[11],"for":[12],"grid-tied":[13],"solar":[14],"photovoltaic":[15],"(PV)":[16],"systems.":[17],"Nonetheless,":[18],"issues":[19],"like":[20],"common-mode":[21],"voltage":[22,57,67,136],"(CMV),":[23],"leakage":[24,108],"current,":[25],"intricate":[27],"circuit":[28],"structures":[29],"restrict":[30],"their":[31],"application":[32],"in":[33,126,134],"medium-voltage":[34],"PV":[35],"applications.":[36],"This":[37],"work":[38],"proposes":[39],"novel":[41],"Boosting":[42],"Common-Ground":[43],"type":[44],"MLI":[45],"(BCGMLI)":[46],"with":[47],"an":[48],"optimal":[49],"component":[50,70],"count.":[51],"It":[52],"provides":[53],"step-up":[55],"output":[56],"while":[58],"using":[59],"less":[60],"components":[61],"than":[62],"most":[63],"state-of-the-art":[64],"topologies.":[65],"Improved":[66],"control,":[68],"reduced":[69],"count,":[71],"self-balanced":[72],"capacitor-based":[73],"boosting,":[74],"higher":[76],"efficiency":[77],"are":[78],"all":[79],"benefits":[80],"of":[81,107,121,173],"the":[82,105,143,169,174],"proposed":[83,100,117,175],"circuit.":[84],"In":[85,115],"order":[86],"to":[87],"generate":[88],"9-level":[90,176],"two-fold":[91],"voltage,":[92],"BCGMLI":[93,118],"uses":[94],"only":[95],"nine":[96],"power":[97,141,149],"switches.":[98],"The":[99,166],"inverter":[101],"architecture":[102],"successfully":[103],"resolves":[104],"problem":[106],"current":[109],"through":[110],"its":[111],"common":[112],"grounding":[113],"feature.":[114],"addition,":[116],"is":[119],"capable":[120],"operating":[122],"under":[123],"sudden":[124,132],"changes":[125,133],"modulation":[127],"index,":[128],"load":[129],"disturbance":[130],"conditions,":[131],"input":[135],"magnitude,":[137],"managing":[139],"reactive":[140],"when":[142],"grid":[144],"experiences":[145],"lagging":[146],"or":[147],"leading":[148],"factor":[150],"conditions.":[151],"Detailed":[152],"design":[153],"guidelines,":[154],"loss":[155],"evaluation,":[156],"closed-loop":[158],"control":[159],"supported":[160],"by":[161],"MATLAB/Simulink":[162],"experimental":[164],"validation.":[165],"results":[167],"validate":[168],"operation":[170],"workability":[172],"BCGMLI.":[177]},"counts_by_year":[],"updated_date":"2025-12-11T23:09:37.256380","created_date":"2025-12-04T00:00:00"}
