{"id":"https://openalex.org/W4415970951","doi":"https://doi.org/10.1109/access.2025.3629624","title":"A Comparative Study of Performance of Various Deep Learning Models and Their Explainability in Detection of Glaucoma","display_name":"A Comparative Study of Performance of Various Deep Learning Models and Their Explainability in Detection of Glaucoma","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4415970951","doi":"https://doi.org/10.1109/access.2025.3629624"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3629624","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3629624","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3629624","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036003561","display_name":"N. K. Jisy","orcid":"https://orcid.org/0000-0002-3788-719X"},"institutions":[{"id":"https://openalex.org/I4210101034","display_name":"Birla Institute of Technology and Science - Hyderabad Campus","ror":"https://ror.org/014ctt859","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210101034","https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"N. K. Jisy","raw_affiliation_strings":["Electrical and Electronics Engineering Department, BITS Pilani, Hyderabad Campus, Hyderabad, India"],"raw_orcid":"https://orcid.org/0000-0002-3788-719X","affiliations":[{"raw_affiliation_string":"Electrical and Electronics Engineering Department, BITS Pilani, Hyderabad Campus, Hyderabad, India","institution_ids":["https://openalex.org/I4210101034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003565762","display_name":"Sudha Radhika","orcid":"https://orcid.org/0000-0002-4741-2913"},"institutions":[{"id":"https://openalex.org/I4210101034","display_name":"Birla Institute of Technology and Science - Hyderabad Campus","ror":"https://ror.org/014ctt859","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210101034","https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sudha Radhika","raw_affiliation_strings":["Electrical and Electronics Engineering Department, BITS Pilani, Hyderabad Campus, Hyderabad, India"],"raw_orcid":"https://orcid.org/0000-0002-4741-2913","affiliations":[{"raw_affiliation_string":"Electrical and Electronics Engineering Department, BITS Pilani, Hyderabad Campus, Hyderabad, India","institution_ids":["https://openalex.org/I4210101034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025108218","display_name":"Sirisha Senthil","orcid":"https://orcid.org/0000-0003-1748-8850"},"institutions":[{"id":"https://openalex.org/I2801255070","display_name":"L V Prasad Eye Institute","ror":"https://ror.org/01w8z9742","country_code":"IN","type":"funder","lineage":["https://openalex.org/I2801255070"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sirisha Senthil","raw_affiliation_strings":["VST Center for Glaucoma Care, L V Prasad Eye Institute, Hyderabad, India","LV Prasad Eye Institute, Hyderabad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"VST Center for Glaucoma Care, L V Prasad Eye Institute, Hyderabad, India","institution_ids":["https://openalex.org/I2801255070"]},{"raw_affiliation_string":"LV Prasad Eye Institute, Hyderabad, India","institution_ids":["https://openalex.org/I2801255070"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040702094","display_name":"M. Srinivas","orcid":"https://orcid.org/0000-0002-5431-0990"},"institutions":[{"id":"https://openalex.org/I142809039","display_name":"Jawaharlal Nehru Technological University, Kakinada","ror":"https://ror.org/05s9t8c95","country_code":"IN","type":"education","lineage":["https://openalex.org/I142809039"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"M. B. Srinivas","raw_affiliation_strings":["Aditya University, Kakinada, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Aditya University, Kakinada, India","institution_ids":["https://openalex.org/I142809039"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.8661,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.7913294,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":"13","issue":null,"first_page":"192891","last_page":"192905"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11438","display_name":"Retinal Imaging and Analysis","score":0.9542999863624573,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11438","display_name":"Retinal Imaging and Analysis","score":0.9542999863624573,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10862","display_name":"AI in cancer detection","score":0.003599999938160181,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/glaucoma","display_name":"Glaucoma","score":0.7973999977111816},{"id":"https://openalex.org/keywords/deep-learning","display_name":"Deep learning","score":0.734499990940094},{"id":"https://openalex.org/keywords/hyperparameter","display_name":"Hyperparameter","score":0.6560999751091003},{"id":"https://openalex.org/keywords/fundus","display_name":"Fundus (uterus)","score":0.5723000168800354},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.550599992275238},{"id":"https://openalex.org/keywords/receiver-operating-characteristic","display_name":"Receiver operating characteristic","score":0.5424000024795532},{"id":"https://openalex.org/keywords/transfer-of-learning","display_name":"Transfer of learning","score":0.5268999934196472}],"concepts":[{"id":"https://openalex.org/C2778527774","wikidata":"https://www.wikidata.org/wiki/Q159701","display_name":"Glaucoma","level":2,"score":0.7973999977111816},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.7498000264167786},{"id":"https://openalex.org/C108583219","wikidata":"https://www.wikidata.org/wiki/Q197536","display_name":"Deep learning","level":2,"score":0.734499990940094},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7311000227928162},{"id":"https://openalex.org/C8642999","wikidata":"https://www.wikidata.org/wiki/Q4171168","display_name":"Hyperparameter","level":2,"score":0.6560999751091003},{"id":"https://openalex.org/C2776391266","wikidata":"https://www.wikidata.org/wiki/Q9612","display_name":"Fundus (uterus)","level":2,"score":0.5723000168800354},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.550599992275238},{"id":"https://openalex.org/C58471807","wikidata":"https://www.wikidata.org/wiki/Q327120","display_name":"Receiver operating characteristic","level":2,"score":0.5424000024795532},{"id":"https://openalex.org/C150899416","wikidata":"https://www.wikidata.org/wiki/Q1820378","display_name":"Transfer of learning","level":2,"score":0.5268999934196472},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.46880000829696655},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.35659998655319214},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3443000018596649},{"id":"https://openalex.org/C3020225094","wikidata":"https://www.wikidata.org/wiki/Q80091","display_name":"Area under curve","level":3,"score":0.3296000063419342},{"id":"https://openalex.org/C55020928","wikidata":"https://www.wikidata.org/wiki/Q3813865","display_name":"Image quality","level":3,"score":0.2906000018119812},{"id":"https://openalex.org/C81363708","wikidata":"https://www.wikidata.org/wiki/Q17084460","display_name":"Convolutional neural network","level":2,"score":0.2822999954223633},{"id":"https://openalex.org/C2776474195","wikidata":"https://www.wikidata.org/wiki/Q1144413","display_name":"Fundus photography","level":4,"score":0.26649999618530273},{"id":"https://openalex.org/C2779735895","wikidata":"https://www.wikidata.org/wiki/Q16873995","display_name":"Optic disc","level":3,"score":0.25360000133514404}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2025.3629624","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3629624","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:2ed2f46ea38a4321a02fa6f6d1ad8f9d","is_oa":true,"landing_page_url":"https://doaj.org/article/2ed2f46ea38a4321a02fa6f6d1ad8f9d","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 192891-192905 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3629624","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3629624","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Glaucoma":[0],"is":[1,60,89],"a":[2,45,128,166,173,192],"serious":[3],"eye-debilitating":[4],"disease":[5],"affecting":[6],"around":[7],"76":[8],"million":[9],"people":[10],"worldwide.":[11],"In":[12,54],"this":[13],"work,":[14],"we":[15],"apply":[16],"deep":[17,72],"learning":[18,77],"models,":[19],"CNN":[20,51,73],"and":[21,33,52,68,71,113,146,182,198],"Vision":[22,47],"Transformer":[23],"(ViT),":[24],"to":[25,50,91,107,123],"understand":[26,92],"their":[27],"performance":[28,41],"in":[29,98,109,135,200],"discriminating":[30],"the":[31,40,55,65,83,93,102,110,138,149,158,201],"normal":[32],"glaucomatous":[34],"fundus":[35,58,111],"images.":[36],"We":[37],"further":[38],"study":[39],"of":[42,100,104,137,160,169,175,180,185,203],"Swin":[43,69],"Transformer,":[44,48],"hierarchical":[46],"relative":[49],"ViT.":[53],"proposed":[56],"approach,":[57],"pre-processing":[59],"carried":[61],"out":[62],"before":[63],"training":[64],"pre-trained":[66],"ViT":[67,126],"variants,":[70],"models":[74],"with":[75,127,172],"transfer":[76],"under":[78,148],"tuned":[79],"hyperparameter":[80],"settings.":[81],"Additionally,":[82],"explainable":[84],"AI":[85],"(XAI)":[86],"technique":[87],"-Grad-CAM-":[88],"used":[90],"model":[94,131,164,194],"that":[95,125,188],"performs":[96,132],"better":[97,116,133,193],"terms":[99,136],"visualizing":[101],"areas":[103],"damage":[105],"due":[106],"glaucoma":[108],"image":[112],"thus":[114],"has":[115],"explainability.":[117],"The":[118],"experimental":[119],"results":[120],"obtained":[121],"appear":[122],"indicate":[124],"pretrained":[129],"ViT_B32":[130],"both":[134],"quality":[139],"metrics":[140],"such":[141],"as":[142,155,157],"accuracy,":[143],"sensitivity,":[144],"specificity":[145],"area":[147],"receiver":[150],"operating":[151],"characteristic":[152],"curve":[153],"(AUC),":[154],"well":[156],"explainability":[159],"results.":[161],"This":[162],"(ViT_B32)":[163],"exhibits":[165],"remarkable":[167],"accuracy":[168,197],"96.19%,":[170],"along":[171],"sensitivity":[174,199],"99.01%,":[176],"an":[177,183],"F1":[178],"score":[179],"0.96,":[181],"AUC":[184],"0.995,":[186],"indicating":[187],"it":[189],"could":[190],"be":[191],"for":[195],"improved":[196],"detection":[202],"glaucoma.":[204]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-11-06T00:00:00"}
