{"id":"https://openalex.org/W4415222026","doi":"https://doi.org/10.1109/access.2025.3621845","title":"A New Approach for HVac to HVdc Conversion Based on Line-Commutated Converter Topology","display_name":"A New Approach for HVac to HVdc Conversion Based on Line-Commutated Converter Topology","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4415222026","doi":"https://doi.org/10.1109/access.2025.3621845"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3621845","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3621845","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3621845","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Shoaib Shaikh","orcid":"https://orcid.org/0000-0002-1383-6814"},"institutions":[{"id":"https://openalex.org/I143804889","display_name":"Loughborough University","ror":"https://ror.org/04vg4w365","country_code":"GB","type":"education","lineage":["https://openalex.org/I143804889"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Shoaib Shaikh","raw_affiliation_strings":["Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough, U.K","Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, United Kingdom"],"raw_orcid":"https://orcid.org/0000-0002-1383-6814","affiliations":[{"raw_affiliation_string":"Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough, U.K","institution_ids":["https://openalex.org/I143804889"]},{"raw_affiliation_string":"Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, United Kingdom","institution_ids":["https://openalex.org/I143804889"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066050480","display_name":"Mohamed S. Diab","orcid":"https://orcid.org/0000-0001-8466-2981"},"institutions":[{"id":"https://openalex.org/I143804889","display_name":"Loughborough University","ror":"https://ror.org/04vg4w365","country_code":"GB","type":"education","lineage":["https://openalex.org/I143804889"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Mohamed Diab","raw_affiliation_strings":["Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough, U.K","Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, United Kingdom"],"raw_orcid":"https://orcid.org/0000-0001-8466-2981","affiliations":[{"raw_affiliation_string":"Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough, U.K","institution_ids":["https://openalex.org/I143804889"]},{"raw_affiliation_string":"Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, United Kingdom","institution_ids":["https://openalex.org/I143804889"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045075603","display_name":"Ahmed Elserougi","orcid":"https://orcid.org/0000-0002-8961-3051"},"institutions":[{"id":"https://openalex.org/I84524832","display_name":"Alexandria University","ror":"https://ror.org/00mzz1w90","country_code":"EG","type":"education","lineage":["https://openalex.org/I84524832"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Ahmed Elserougi","raw_affiliation_strings":["Electrical Engineering Department, Alexandria University, Alexandria, Egypt"],"raw_orcid":"https://orcid.org/0000-0002-8961-3051","affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Alexandria University, Alexandria, Egypt","institution_ids":["https://openalex.org/I84524832"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.24355647,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"13","issue":null,"first_page":"180632","last_page":"180646"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9830999970436096,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9502999782562256,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.6886000037193298},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.48730000853538513},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4674000144004822},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.46230000257492065},{"id":"https://openalex.org/keywords/hvdc-converter-station","display_name":"HVDC converter station","score":0.459199994802475},{"id":"https://openalex.org/keywords/thyristor","display_name":"Thyristor","score":0.4514000117778778},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4447999894618988},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.41119998693466187}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.6886000037193298},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6190999746322632},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.48730000853538513},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4674000144004822},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.46230000257492065},{"id":"https://openalex.org/C7904685","wikidata":"https://www.wikidata.org/wiki/Q2356943","display_name":"HVDC converter station","level":3,"score":0.459199994802475},{"id":"https://openalex.org/C121922863","wikidata":"https://www.wikidata.org/wiki/Q180805","display_name":"Thyristor","level":3,"score":0.4514000117778778},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4447999894618988},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4142000079154968},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.41119998693466187},{"id":"https://openalex.org/C2780705257","wikidata":"https://www.wikidata.org/wiki/Q5636221","display_name":"HVDC converter","level":4,"score":0.4097000062465668},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40139999985694885},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3977999985218048},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3725000023841858},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.3610999882221222},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.3443000018596649},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3325999975204468},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.33009999990463257},{"id":"https://openalex.org/C2781089630","wikidata":"https://www.wikidata.org/wiki/Q21856745","display_name":"Realization (probability)","level":2,"score":0.30559998750686646},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.30070000886917114},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2639999985694885},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.257999986410141},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.25609999895095825}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/access.2025.3621845","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3621845","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:7ec9eb63020a4248bbd0fb89226a7e69","is_oa":true,"landing_page_url":"https://doaj.org/article/7ec9eb63020a4248bbd0fb89226a7e69","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 180632-180646 (2025)","raw_type":"article"},{"id":"pmh:oai:figshare.com:article/30347116","is_oa":true,"landing_page_url":"https://figshare.com/articles/journal_contribution/A_new_approach_for_HVAC_to_HVDC_conversion_based_on_line-commutated_converter_topology/30347116","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Text"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3621845","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3621845","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,132,168],"global":[1],"pursuit":[2],"of":[3,10,24,71,113,145,173,175,195],"sustainable":[4],"development":[5],"has":[6],"intensified":[7],"the":[8,69,103,109,121,126,143,162,171,176,193],"integration":[9,194],"renewable":[11],"energy":[12],"sources,":[13],"placing":[14],"growing":[15],"demands":[16],"on":[17,85],"electrical":[18],"grids":[19],"to":[20,47,59,78,92,154,210],"transmit":[21],"large":[22],"volumes":[23],"carbon-free":[25],"power":[26,124],"via":[27],"existing":[28,55],"transmission":[29,41,57,76,227],"corridors":[30,58],"that":[31],"are":[32,215],"already":[33],"operating":[34],"at":[35],"or":[36],"nearing":[37],"capacity.":[38],"Constructing":[39],"new":[40],"lines":[42],"is":[43],"significantly":[44],"challenging":[45],"due":[46],"regulatory":[48],"restraints":[49],"and":[50,100,151,156,182,204,217],"public":[51],"opposition.":[52],"Alternatively,":[53],"upgrading":[54],"HVAC":[56,75],"HVDC":[60,82,96,202,226],"operation":[61,174],"offers":[62],"a":[63,79,86,187,199,220],"practical":[64],"solution.":[65],"This":[66],"paper":[67,169],"proposes":[68,192],"conversion":[70],"widely":[72],"adopted":[73],"double-circuit":[74],"systems":[77,97],"six-wire":[80,95,200],"bipolar":[81,201,225],"configuration":[83,107,134],"based":[84],"9-pulse":[87,105,177],"line-commutated":[88],"converter":[89,106,165,197],"(LCC).":[90],"Compared":[91],"equivalently":[93],"rated":[94],"employing":[98],"6-pulse":[99,155],"12-pulse":[101,157],"converters,":[102],"proposed":[104,133],"reduces":[108],"total":[110,164],"RMS":[111],"value":[112],"AC":[114],"grid":[115],"current":[116],"by":[117,149],"16.67%":[118],"while":[119,160],"delivering":[120],"same":[122,163],"DC":[123],"without":[125],"need":[127],"for":[128],"additional":[129],"VAR":[130],"support.":[131],"also":[135],"achieves":[136],"substantial":[137],"reductions":[138],"in":[139,230],"hardware":[140,188],"complexity,":[141],"lowering":[142],"number":[144],"required":[146],"thyristor":[147],"valves":[148],"50%":[150],"75%":[152],"compared":[153],"systems,":[158],"respectively,":[159],"maintaining":[161],"VA":[166],"rating.":[167],"presents":[170],"principle":[172],"LCC":[178],"through":[179],"mathematical":[180],"analysis":[181],"validates":[183],"its":[184],"performance":[185],"using":[186,219],"prototype.":[189],"It":[190],"further":[191],"this":[196,211],"within":[198],"system":[203],"introduces":[205],"fault":[206],"isolation":[207],"strategies":[208,214],"tailored":[209],"configuration.":[212],"These":[213],"demonstrated":[216],"verified":[218],"6000":[221],"MW,":[222],"275":[223],"kV":[224],"model":[228],"developed":[229],"MATLAB/Simulink.":[231]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-16T00:00:00"}
