{"id":"https://openalex.org/W7082260591","doi":"https://doi.org/10.1109/access.2025.3612191","title":"Valve-Side Single-Phase-to-Ground Fault Clearance in Bipolar Hybrid-MMC HVDC Systems Utilizing Thyristor Commutation Branches and Mechanical Interrupter","display_name":"Valve-Side Single-Phase-to-Ground Fault Clearance in Bipolar Hybrid-MMC HVDC Systems Utilizing Thyristor Commutation Branches and Mechanical Interrupter","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W7082260591","doi":"https://doi.org/10.1109/access.2025.3612191"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3612191","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3612191","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3612191","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Muhammad Usman","orcid":"https://orcid.org/0000-0001-9052-4315"},"institutions":[{"id":"https://openalex.org/I4575257","display_name":"Hanyang University","ror":"https://ror.org/046865y68","country_code":"KR","type":"education","lineage":["https://openalex.org/I4575257"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Muhammad Usman","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea"],"raw_orcid":"https://orcid.org/0000-0001-9052-4315","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea","institution_ids":["https://openalex.org/I4575257"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Il Kwon","orcid":"https://orcid.org/0000-0003-3595-3672"},"institutions":[{"id":"https://openalex.org/I4575257","display_name":"Hanyang University","ror":"https://ror.org/046865y68","country_code":"KR","type":"education","lineage":["https://openalex.org/I4575257"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Il Kwon","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-3595-3672","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea","institution_ids":["https://openalex.org/I4575257"]}]},{"author_position":"last","author":{"id":null,"display_name":"Bang-Wook Lee","orcid":"https://orcid.org/0000-0001-9975-8812"},"institutions":[{"id":"https://openalex.org/I4575257","display_name":"Hanyang University","ror":"https://ror.org/046865y68","country_code":"KR","type":"education","lineage":["https://openalex.org/I4575257"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Bang-Wook Lee","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea"],"raw_orcid":"https://orcid.org/0000-0001-9975-8812","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, HVDC Electric Power Laboratory, Hanyang University, Ansan, South Korea","institution_ids":["https://openalex.org/I4575257"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4575257"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":2.792,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.92619627,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":98},"biblio":{"volume":"13","issue":null,"first_page":"166630","last_page":"166648"},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T12157","display_name":"Geochemistry and Geologic Mapping","score":0.6589999794960022,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12157","display_name":"Geochemistry and Geologic Mapping","score":0.6589999794960022,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13067","display_name":"Geological Modeling and Analysis","score":0.026200000196695328,"subfield":{"id":"https://openalex.org/subfields/1906","display_name":"Geochemistry and Petrology"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14311","display_name":"Electrical and Electromagnetic Research","score":0.020099999383091927,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thyristor","display_name":"Thyristor","score":0.8317000269889832},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.7731000185012817},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6733999848365784},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.6539999842643738},{"id":"https://openalex.org/keywords/commutation","display_name":"Commutation","score":0.6402999758720398},{"id":"https://openalex.org/keywords/interrupter","display_name":"Interrupter","score":0.5425999760627747},{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.4756999909877777},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.45179998874664307}],"concepts":[{"id":"https://openalex.org/C121922863","wikidata":"https://www.wikidata.org/wiki/Q180805","display_name":"Thyristor","level":3,"score":0.8317000269889832},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.7731000185012817},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6733999848365784},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.6539999842643738},{"id":"https://openalex.org/C2780147050","wikidata":"https://www.wikidata.org/wiki/Q5155085","display_name":"Commutation","level":3,"score":0.6402999758720398},{"id":"https://openalex.org/C21778337","wikidata":"https://www.wikidata.org/wiki/Q6056647","display_name":"Interrupter","level":2,"score":0.5425999760627747},{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.4756999909877777},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.45179998874664307},{"id":"https://openalex.org/C138944611","wikidata":"https://www.wikidata.org/wiki/Q1163287","display_name":"Clearance","level":2,"score":0.44600000977516174},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4413999915122986},{"id":"https://openalex.org/C157069517","wikidata":"https://www.wikidata.org/wiki/Q132172","display_name":"Arc-fault circuit interrupter","level":4,"score":0.4284000098705292},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42160001397132874},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3853999972343445},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.35589998960494995},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3425000011920929},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3027999997138977},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.26750001311302185},{"id":"https://openalex.org/C194777113","wikidata":"https://www.wikidata.org/wiki/Q1066563","display_name":"Integrated gate-commutated thyristor","level":4,"score":0.26019999384880066},{"id":"https://openalex.org/C28285623","wikidata":"https://www.wikidata.org/wiki/Q176110","display_name":"Insulated-gate bipolar transistor","level":3,"score":0.2599000036716461},{"id":"https://openalex.org/C2780705257","wikidata":"https://www.wikidata.org/wiki/Q5636221","display_name":"HVDC converter","level":4,"score":0.2572999894618988}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2025.3612191","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3612191","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:8659db1e0a904eee85e169224b1e1a8a","is_oa":true,"landing_page_url":"https://doaj.org/article/8659db1e0a904eee85e169224b1e1a8a","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 166630-166648 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3612191","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3612191","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1514055819","display_name":null,"funder_award_id":"20224000000160","funder_id":"https://openalex.org/F4320335199","funder_display_name":"Korea Institute of Energy Technology Evaluation and Planning"}],"funders":[{"id":"https://openalex.org/F4320335199","display_name":"Korea Institute of Energy Technology Evaluation and Planning","ror":"https://ror.org/02zq38y32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W2008773359","https://openalex.org/W2951741982","https://openalex.org/W2968875725","https://openalex.org/W2996202171","https://openalex.org/W3007466407","https://openalex.org/W3172253937","https://openalex.org/W3207512738","https://openalex.org/W3211814286","https://openalex.org/W3217475830","https://openalex.org/W4293193106","https://openalex.org/W4312272281","https://openalex.org/W4315630748","https://openalex.org/W4361794940","https://openalex.org/W4387986713","https://openalex.org/W4392024470","https://openalex.org/W4400729121","https://openalex.org/W4400877834","https://openalex.org/W4406891941","https://openalex.org/W4408017148","https://openalex.org/W4409076735"],"related_works":[],"abstract_inverted_index":{"The":[0,113,195],"Hybrid":[1],"Modular":[2],"Multilevel":[3],"Converter":[4],"(HMMC)":[5],"topology&#x2014;comprising":[6],"full-bridge":[7,27,74],"(FB)":[8],"and":[9,95,135,177,217],"half-bridge":[10],"(HB)":[11],"submodules&#x2014;is":[12],"effective":[13],"for":[14,51,61,108,206,225],"DC":[15,110,160],"fault":[16,34,40,63,83,111,173,203,222],"clearance":[17,204,223],"in":[18,25,41,174],"HVDC":[19,43],"systems.":[20,209,227],"However,":[21],"to":[22,59,141],"prevent":[23],"overvoltage":[24,118,169],"lower-arm":[26,117],"submodules":[28],"(FBSMs)":[29],"during":[30,192],"valve-side":[31,172],"single-phase-to-ground":[32],"(SPG)":[33],"mitigation&#x2014;an":[35],"uncommon":[36],"yet":[37],"critical":[38],"internal":[39],"bipolar":[42,180,208],"systems&#x2014;the":[44],"proportion":[45],"of":[46,54,70,105],"FBSMs":[47,106],"used":[48],"must":[49],"account":[50],"approximately":[52],"86.6%":[53],"the":[55,67,92,102,123,128,143,148],"arm":[56],"voltage,":[57],"compared":[58,199],"43.3%":[60],"DC-side":[62],"blocking.":[64],"This":[65,77],"diminishes":[66],"economic":[68],"advantage":[69],"HMMC":[71,81,179,207,226],"over":[72],"fully":[73],"MMC":[75],"topology.":[76],"paper":[78],"proposes":[79],"an":[80],"SPG":[82,171,202,221],"mitigation":[84],"method":[85,114,197],"using":[86,153],"thyristor-based":[87],"current":[88,121,150],"commutation":[89],"branches":[90,138],"on":[91],"lower":[93,132],"arms":[94,133],"a":[96,154],"ground-side":[97],"mechanical":[98,129,155],"interrupter,":[99],"while":[100],"maintaining":[101],"minimum":[103],"number":[104],"required":[107],"conventional":[109],"clearance.":[112],"mitigates":[115],"SPG-resultant":[116],"by":[119],"commutating":[120],"into":[122],"thyristor":[124,137],"branches,":[125],"after":[126],"which":[127],"interrupter":[130],"clear":[131,142],"current,":[134],"subsequently":[136],"are":[139],"turned-off":[140],"SPG-valve":[144],"side":[145],"fault.":[146],"Additionally,":[147],"pole":[149],"is":[151,185,198,212],"cleared":[152],"breaker":[156,162],"or":[157],"passive":[158],"oscillation":[159],"circuit":[161],"(CB),":[163],"effectively":[164],"suppressing":[165],"upper-arm":[166],"submodule":[167],"(SM)":[168],"under":[170],"both":[175],"short-":[176],"long-distance":[178],"links.":[181],"Although":[182],"additional":[183],"equipment":[184],"required,":[186],"it":[187],"incurs":[188],"no":[189],"on-state":[190],"losses":[191],"steady-state":[193],"operation.":[194],"proposed":[196],"with":[200],"existing":[201],"approaches":[205],"Its":[210],"effectiveness":[211],"validated":[213],"through":[214],"PSCAD/EMTDC":[215],"simulations":[216],"benchmarked":[218],"against":[219],"prior":[220],"methods":[224]},"counts_by_year":[{"year":2026,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
