{"id":"https://openalex.org/W4413212880","doi":"https://doi.org/10.1109/access.2025.3597555","title":"Early Detection of Voltage Instability: A Transparent, Rule-Based Method for Cyber-Resilient Grids","display_name":"Early Detection of Voltage Instability: A Transparent, Rule-Based Method for Cyber-Resilient Grids","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4413212880","doi":"https://doi.org/10.1109/access.2025.3597555"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3597555","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3597555","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3597555","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073259312","display_name":"Mahtab Khalilifar","orcid":"https://orcid.org/0000-0002-2397-2350"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Mahtab Khalilifar","raw_affiliation_strings":["Center of Excellence for Power System Automation and Operation, Iran University of Science and Technology (IUST), Tehran, Iran","Iran University of Science and Technology (IUST), Tehran, Iran"],"raw_orcid":"https://orcid.org/0000-0002-2397-2350","affiliations":[{"raw_affiliation_string":"Center of Excellence for Power System Automation and Operation, Iran University of Science and Technology (IUST), Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]},{"raw_affiliation_string":"Iran University of Science and Technology (IUST), Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041918531","display_name":"S. Mohammad Shahrtash","orcid":"https://orcid.org/0000-0003-4459-5416"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Seyed Mohammad Shahrtash","raw_affiliation_strings":["Center of Excellence for Power System Automation and Operation, Iran University of Science and Technology (IUST), Tehran, Iran","Iran University of Science and Technology (IUST), Tehran, Iran"],"raw_orcid":"https://orcid.org/0000-0003-4459-5416","affiliations":[{"raw_affiliation_string":"Center of Excellence for Power System Automation and Operation, Iran University of Science and Technology (IUST), Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]},{"raw_affiliation_string":"Iran University of Science and Technology (IUST), Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I67009956"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.6668,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.83582796,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":98},"biblio":{"volume":"13","issue":null,"first_page":"142262","last_page":"142273"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6185162663459778},{"id":"https://openalex.org/keywords/instability","display_name":"Instability","score":0.5865813493728638},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4843372106552124},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.25840604305267334},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.17321431636810303},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1234143078327179},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.09470492601394653}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6185162663459778},{"id":"https://openalex.org/C207821765","wikidata":"https://www.wikidata.org/wiki/Q405372","display_name":"Instability","level":2,"score":0.5865813493728638},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4843372106552124},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25840604305267334},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17321431636810303},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1234143078327179},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.09470492601394653}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2025.3597555","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3597555","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:2d137b1406b74ee2a4ca737657c1cf1c","is_oa":true,"landing_page_url":"https://doaj.org/article/2d137b1406b74ee2a4ca737657c1cf1c","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 142262-142273 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3597555","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3597555","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.5400000214576721}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W342184714","https://openalex.org/W1810417556","https://openalex.org/W2052950518","https://openalex.org/W2314206269","https://openalex.org/W2400278024","https://openalex.org/W2664867576","https://openalex.org/W2896795036","https://openalex.org/W2907043440","https://openalex.org/W2978428898","https://openalex.org/W3036697987","https://openalex.org/W3036700726","https://openalex.org/W3109926422","https://openalex.org/W3110874572","https://openalex.org/W3186803900","https://openalex.org/W3195509656","https://openalex.org/W4285103565","https://openalex.org/W4309988912","https://openalex.org/W4310359162","https://openalex.org/W4401536987","https://openalex.org/W4405934653","https://openalex.org/W4408709476"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W2022300913","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W1570780624"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,16,172],"rule-based":[4,85],"algorithm":[5,112],"for":[6,21,46,107,118,176,182],"fast":[7],"prediction":[8,144],"of":[9,151],"long-term":[10,103],"voltage":[11,104,142],"stability":[12,69,120,143,178],"status":[13],"immediately":[14],"after":[15],"disturbance,":[17],"eliminating":[18],"the":[19,39,55,110,169],"need":[20],"post-disturbance":[22],"measurements.":[23],"Unlike":[24],"traditional":[25],"Phasor":[26],"Measurement":[27],"Unit":[28],"(PMU)":[29],"dependent":[30],"methods":[31],"vulnerable":[32],"to":[33,90,155],"cyber":[34],"threats":[35],"like":[36],"data":[37,44],"spoofing,":[38],"proposed":[40],"approach":[41],"uses":[42],"PMU":[43],"only":[45],"initial":[47],"system":[48,58],"updates.":[49],"It":[50],"first":[51],"validates":[52],"measurements":[53],"against":[54],"last":[56],"trusted":[57],"state":[59],"using":[60],"consistency":[61],"checks,":[62],"corrects":[63],"any":[64],"discrepancies,":[65],"and":[66,76,99,131,140,157],"then":[67],"bases":[68],"decisions":[70],"on":[71,124],"inherent":[72],"characteristics\u2014power":[73],"flow":[74],"convergence":[75],"generator":[77],"reactive":[78],"power":[79],"margins\u2014ensuring":[80],"cyber-resilient":[81],"operation.":[82],"The":[83,166],"method\u2019s":[84],"logic":[86],"ensures":[87],"intrinsic":[88],"immunity":[89],"cybersecurity":[91],"risks":[92],"while":[93],"maintaining":[94],"compatibility":[95],"with":[96],"both":[97],"large":[98],"small":[100],"disturbances":[101,133],"triggering":[102],"instability.":[105],"Optimized":[106],"real-time":[108],"operation,":[109],"simulation-based":[111],"meets":[113],"stringent":[114],"computational":[115],"speed":[116],"requirements":[117],"online":[119],"assessment.":[121],"Comprehensive":[122],"simulations":[123],"IEEE":[125],"test":[126,164],"systems":[127],"under":[128],"N-1/N-2":[129],"contingencies":[130],"load":[132],"demonstrate":[134],"three":[135],"key":[136],"advantages:":[137],"1)":[138],"Early":[139],"accurate":[141],"(96.8%":[145],"detection":[146],"accuracy),":[147],"2)":[148],"Reliable":[149],"identification":[150],"critical":[152],"generators/loads":[153],"contributing":[154],"instability,":[156],"3)":[158],"Cyber-resilient":[159],"operation":[160],"verified":[161],"through":[162],"adversarial":[163],"cases.":[165],"results":[167],"establish":[168],"method":[170],"as":[171],"transparent,":[173],"infrastructure-independent":[174],"solution":[175],"grid":[177],"monitoring,":[179],"particularly":[180],"valuable":[181],"cybersecurity-sensitive":[183],"environments.":[184]},"counts_by_year":[{"year":2026,"cited_by_count":2}],"updated_date":"2025-12-23T23:11:35.936235","created_date":"2025-10-10T00:00:00"}
