{"id":"https://openalex.org/W4411639881","doi":"https://doi.org/10.1109/access.2025.3582967","title":"Defect Detection of Gas Insulation Switch by Infrared Thermography Technology With an Improved Yolo Algorithm","display_name":"Defect Detection of Gas Insulation Switch by Infrared Thermography Technology With an Improved Yolo Algorithm","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4411639881","doi":"https://doi.org/10.1109/access.2025.3582967"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3582967","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3582967","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3582967","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5118628651","display_name":"Ma Tianci","orcid":null},"institutions":[{"id":"https://openalex.org/I178232147","display_name":"Guizhou University","ror":"https://ror.org/02wmsc916","country_code":"CN","type":"education","lineage":["https://openalex.org/I178232147"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ma Tianci","raw_affiliation_strings":["School of Electrical Engineering, Guizhou University, Guiyang, Guizhou, China","School of Electrical Engineering, Guizhou University, Guizhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Guizhou University, Guiyang, Guizhou, China","institution_ids":["https://openalex.org/I178232147"]},{"raw_affiliation_string":"School of Electrical Engineering, Guizhou University, Guizhou, China","institution_ids":["https://openalex.org/I178232147"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029802757","display_name":"Xiangping Chen","orcid":"https://orcid.org/0000-0002-6064-4508"},"institutions":[{"id":"https://openalex.org/I178232147","display_name":"Guizhou University","ror":"https://ror.org/02wmsc916","country_code":"CN","type":"education","lineage":["https://openalex.org/I178232147"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chen Xiangping","raw_affiliation_strings":["School of Electrical Engineering, Guizhou University, Guiyang, Guizhou, China","School of Electrical Engineering, Guizhou University, Guizhou, China"],"raw_orcid":"https://orcid.org/0000-0002-6064-4508","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Guizhou University, Guiyang, Guizhou, China","institution_ids":["https://openalex.org/I178232147"]},{"raw_affiliation_string":"School of Electrical Engineering, Guizhou University, Guizhou, China","institution_ids":["https://openalex.org/I178232147"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100374414","display_name":"Bo Li","orcid":"https://orcid.org/0000-0002-2961-2874"},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Li Bo","raw_affiliation_strings":["Guizhou Power Grid Company Ltd.,, Guiyang, Guizhou, China","Guizhou Power Grid Co., Ltd, Guizhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Guizhou Power Grid Company Ltd.,, Guiyang, Guizhou, China","institution_ids":["https://openalex.org/I4210145500"]},{"raw_affiliation_string":"Guizhou Power Grid Co., Ltd, Guizhou, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"last","author":{"id":null,"display_name":"Bai Jie","orcid":null},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bai Jie","raw_affiliation_strings":["Guizhou Power Grid Company Ltd.,, Guiyang, Guizhou, China","Guizhou Power Grid Co., Ltd, Guizhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Guizhou Power Grid Company Ltd.,, Guiyang, Guizhou, China","institution_ids":["https://openalex.org/I4210145500"]},{"raw_affiliation_string":"Guizhou Power Grid Co., Ltd, Guizhou, China","institution_ids":["https://openalex.org/I4210145500"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.5554,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.84243722,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":98},"biblio":{"volume":"13","issue":null,"first_page":"118212","last_page":"118223"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12111","display_name":"Industrial Vision Systems and Defect Detection","score":0.9455999732017517,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12111","display_name":"Industrial Vision Systems and Defect Detection","score":0.9455999732017517,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13717","display_name":"Advanced Algorithms and Applications","score":0.9427000284194946,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12389","display_name":"Infrared Target Detection Methodologies","score":0.9151999950408936,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermography","display_name":"Thermography","score":0.7752672433853149},{"id":"https://openalex.org/keywords/infrared","display_name":"Infrared","score":0.7344335913658142},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5684878826141357},{"id":"https://openalex.org/keywords/infrared-heater","display_name":"Infrared heater","score":0.45087122917175293},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.44036445021629333},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.24727600812911987},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08706346154212952}],"concepts":[{"id":"https://openalex.org/C2779222261","wikidata":"https://www.wikidata.org/wiki/Q624587","display_name":"Thermography","level":3,"score":0.7752672433853149},{"id":"https://openalex.org/C158355884","wikidata":"https://www.wikidata.org/wiki/Q11388","display_name":"Infrared","level":2,"score":0.7344335913658142},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5684878826141357},{"id":"https://openalex.org/C132815061","wikidata":"https://www.wikidata.org/wiki/Q592813","display_name":"Infrared heater","level":3,"score":0.45087122917175293},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.44036445021629333},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.24727600812911987},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08706346154212952}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2025.3582967","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3582967","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:ce88ec541bd4490ab4e87d0aa0c103dd","is_oa":true,"landing_page_url":"https://doaj.org/article/ce88ec541bd4490ab4e87d0aa0c103dd","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 118212-118223 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3582967","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3582967","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.75}],"awards":[{"id":"https://openalex.org/G3813969400","display_name":null,"funder_award_id":"CG0600022001581510","funder_id":"https://openalex.org/F4320323192","funder_display_name":"China Southern Power Grid"},{"id":"https://openalex.org/G3899247124","display_name":null,"funder_award_id":"GZKJXM20222398","funder_id":"https://openalex.org/F4320336618","funder_display_name":"Science and Technology Program of Suzhou"}],"funders":[{"id":"https://openalex.org/F4320323192","display_name":"China Southern Power Grid","ror":"https://ror.org/03hkh9419"},{"id":"https://openalex.org/F4320336618","display_name":"Science and Technology Program of Suzhou","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W639708223","https://openalex.org/W2084690418","https://openalex.org/W2168356304","https://openalex.org/W2963260018","https://openalex.org/W2997747012","https://openalex.org/W3083485545","https://openalex.org/W3159109890","https://openalex.org/W3177052299","https://openalex.org/W3217031888","https://openalex.org/W4288067097","https://openalex.org/W4378231741","https://openalex.org/W4385758608","https://openalex.org/W4387245290","https://openalex.org/W4387639261","https://openalex.org/W4392506566","https://openalex.org/W4392763860","https://openalex.org/W4394676676","https://openalex.org/W4399526335","https://openalex.org/W4400777596","https://openalex.org/W4405112613","https://openalex.org/W4405205309","https://openalex.org/W4407062605","https://openalex.org/W6746304377"],"related_works":["https://openalex.org/W2514152378","https://openalex.org/W4310007303","https://openalex.org/W2224543647","https://openalex.org/W35959284","https://openalex.org/W2286188758","https://openalex.org/W2141980482","https://openalex.org/W2900544575","https://openalex.org/W4391030883","https://openalex.org/W2513461979","https://openalex.org/W4255358997"],"abstract_inverted_index":{"Gas-insulated":[0],"switch-gear":[1],"(GIS)":[2],"defects,":[3,122],"such":[4],"as":[5],"internal":[6],"bubbles,":[7,126],"surface":[8],"cracks,":[9],"and":[10,26,35,61,66,155,161,168],"high":[11],"pressure":[12],"breakdowns,":[13],"critically":[14],"threaten":[15],"power":[16],"transmission":[17],"reliability.":[18],"However,":[19],"conventional":[20],"nondestructive":[21],"detection":[22,50,169],"methods":[23],"like":[24],"ultrasound":[25],"X-ray":[27],"face":[28],"the":[29,73,85,100,115,129,177,183,186],"challenges":[30],"in":[31,84,99],"anti-interference":[32],"capability,":[33],"cost,":[34],"structural":[36],"complexity.":[37],"To":[38],"address":[39],"those":[40],"issues,":[41],"this":[42],"study":[43],"has":[44,171],"proposed":[45,70,145],"an":[46,55],"infrared":[47,116],"thermography-based":[48],"defect":[49,63,106,200],"method":[51,71,146],"by":[52,76],"combing":[53],"with":[54,81,114,128,176],"enhanced":[56],"YOLOv7":[57,74,160],"algorithm":[58],"for":[59,193,198],"accurate":[60],"efficient":[62],"localization":[64],"identification":[65],"depth":[67],"estimation.":[68],"The":[69,108,136,144],"modifies":[72],"framework":[75],"replacing":[77],"standard":[78],"CBS":[79],"modules":[80],"Fused-MBConv":[82],"layers":[83],"backbone":[86],"to":[87,103],"improve":[88],"feature":[89],"extraction":[90],"efficiency":[91],"while":[92],"integrates":[93],"a":[94,148,190],"coordinate":[95],"attention":[96],"(CA)":[97],"mechanism":[98],"neck":[101],"layer":[102],"enhance":[104],"spatial":[105],"recognition.":[107],"experiments":[109],"have":[110,139],"been":[111,172],"carried":[112],"out":[113],"thermal":[117],"images":[118],"of":[119,153,185],"insulation":[120],"rod":[121],"including":[123],"flashover,":[124],"block":[125],"scratches,":[127],"impurities":[130],"at":[131],"depths":[132],"within":[133],"0.4\u20131":[134],"mm.":[135],"experimental":[137],"results":[138,181],"demonstrated":[140],"significant":[141],"performance":[142],"gains.":[143],"achieves":[147],"mean":[149],"Average":[150],"Precis-ion":[151],"(mAP)":[152],"10.6%":[154],"13%":[156],"higher":[157],"than":[158],"baseline":[159],"YOLOv5,":[162],"respectively.":[163],"Moreover,":[164],"improved":[165],"computational":[166],"speed":[167],"accuracy":[170],"seen":[173],"via":[174],"comparison":[175],"fellow":[178],"algorithms.":[179],"These":[180],"validate":[182],"effectiveness":[184],"method,":[187],"which":[188],"provide":[189],"reference":[191],"solution":[192],"overcoming":[194],"existing":[195],"technological":[196],"barriers":[197],"GIS":[199],"diagnosis.":[201]},"counts_by_year":[{"year":2026,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
