{"id":"https://openalex.org/W4410153081","doi":"https://doi.org/10.1109/access.2025.3567698","title":"A TMR Sensor Array for Non-Invasive Current Measurement in Three-Phase Cable and Error Analysis","display_name":"A TMR Sensor Array for Non-Invasive Current Measurement in Three-Phase Cable and Error Analysis","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4410153081","doi":"https://doi.org/10.1109/access.2025.3567698"},"language":"en","primary_location":{"id":"doi:10.1109/access.2025.3567698","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3567698","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2025.3567698","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063812921","display_name":"Ruixi Luo","orcid":null},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ruixi Luo","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":"https://orcid.org/0009-0006-4513-1305","affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Hui He","orcid":"https://orcid.org/0009-0007-2724-7029"},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Hui He","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":"https://orcid.org/0009-0007-2724-7029","affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100599219","display_name":"Qiang Shi","orcid":"https://orcid.org/0000-0002-9046-2924"},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Qiang Shi","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113949660","display_name":"Junyi Cai","orcid":null},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Junyi Cai","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":"https://orcid.org/0009-0006-5918-3309","affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008228748","display_name":"Ziyang Ye","orcid":"https://orcid.org/0009-0008-1939-216X"},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ziyang Ye","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101709214","display_name":"Xiang Zhang","orcid":"https://orcid.org/0000-0001-5255-285X"},"institutions":[{"id":"https://openalex.org/I867306930","display_name":"Power Grid Corporation (India)","ror":"https://ror.org/0136vj189","country_code":"IN","type":"company","lineage":["https://openalex.org/I867306930"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Xiang Zhang","raw_affiliation_strings":["State Grid Sichuan Electric Power Company, Chengdu, China","State Grid Sichuan Electric Power Company, Chengadu, Chin"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengdu, China","institution_ids":[]},{"raw_affiliation_string":"State Grid Sichuan Electric Power Company, Chengadu, Chin","institution_ids":["https://openalex.org/I867306930"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I867306930"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.9801,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.72891114,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"13","issue":null,"first_page":"80272","last_page":"80282"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14117","display_name":"Integrated Circuits and Semiconductor Failure Analysis","score":0.9754999876022339,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13293","display_name":"Engineering and Test Systems","score":0.9678000211715698,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5913596153259277},{"id":"https://openalex.org/keywords/error-analysis","display_name":"Error analysis","score":0.4909975826740265},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.4843815267086029},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.44976338744163513},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.4403853714466095},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.42676717042922974},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.39817309379577637},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.37137261033058167},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.24017485976219177},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19371438026428223},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.13487955927848816}],"concepts":[{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5913596153259277},{"id":"https://openalex.org/C3018824978","wikidata":"https://www.wikidata.org/wiki/Q2894891","display_name":"Error analysis","level":2,"score":0.4909975826740265},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.4843815267086029},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44976338744163513},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.4403853714466095},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42676717042922974},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.39817309379577637},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.37137261033058167},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.24017485976219177},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19371438026428223},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13487955927848816},{"id":"https://openalex.org/C28826006","wikidata":"https://www.wikidata.org/wiki/Q33521","display_name":"Applied mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2025.3567698","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3567698","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:04ceef865e08491a987ede6ab1a5f768","is_oa":true,"landing_page_url":"https://doaj.org/article/04ceef865e08491a987ede6ab1a5f768","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 80272-80282 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2025.3567698","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2025.3567698","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.41999998688697815}],"awards":[{"id":"https://openalex.org/G3448302353","display_name":null,"funder_award_id":"521997230018","funder_id":"https://openalex.org/F4320336296","funder_display_name":"State Grid Tianjin Electric Power Company"}],"funders":[{"id":"https://openalex.org/F4320336296","display_name":"State Grid Tianjin Electric Power Company","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1944331705","https://openalex.org/W2027347527","https://openalex.org/W2086466318","https://openalex.org/W2127394451","https://openalex.org/W2159572189","https://openalex.org/W2574623201","https://openalex.org/W2589688113","https://openalex.org/W2790374452","https://openalex.org/W2797921732","https://openalex.org/W3028289726","https://openalex.org/W3090220756","https://openalex.org/W3111445345","https://openalex.org/W3152776561","https://openalex.org/W3190575736","https://openalex.org/W4388430357","https://openalex.org/W4395096181"],"related_works":["https://openalex.org/W1982412832","https://openalex.org/W4244464241","https://openalex.org/W2384573129","https://openalex.org/W2351224547","https://openalex.org/W2358945257","https://openalex.org/W4318692582","https://openalex.org/W2991569731","https://openalex.org/W2047091966","https://openalex.org/W1841845823","https://openalex.org/W2355937260"],"abstract_inverted_index":{"The":[0,64,114,130,153],"inevitable":[1],"trajectory":[2],"of":[3,17,25,42,91,99,116,192],"future":[4],"distribution":[5,94],"network":[6],"evolution":[7],"is":[8,32],"characterized":[9],"by":[10,110,159],"automation":[11],"and":[12,27,35,101,145,166,177],"digitization.":[13],"With":[14],"the":[15,23,40,43,47,76,81,88,96,105,117,136,161,164,182],"development":[16],"tunnel":[18],"magnetoresistance":[19],"(TMR)":[20],"sensor":[21,62,131],"technology,":[22],"application":[24],"non-invasive":[26,54,202],"non-contact":[28],"current":[29,55,154,188,203],"detection":[30],"technology":[31],"receiving":[33],"more":[34,36],"attention.":[37],"Based":[38],"on":[39,104],"analysis":[41],"magnetic":[44,60,92,168],"field":[45,61,93],"around":[46],"three-phase":[48,206],"cable,":[49],"this":[50],"paper":[51],"presents":[52],"a":[53,59,72,123,172],"measurement":[56,106,151],"system":[57,65,184],"using":[58,122,135,171],"array.":[63],"employs":[66],"8":[67],"TMR":[68,118],"sensors":[69,119],"arranged":[70],"in":[71,84,95,205],"circular":[73],"array":[74,132],"surrounding":[75],"measured":[77,165],"cable":[78],"to":[79,126,149],"reconstruct":[80,187],"currents":[82],"flowing":[83],"individual":[85],"conductors":[86],"within":[87],"cable.":[89],"Characteristics":[90],"external":[97],"space":[98],"cables":[100],"its":[102,199],"influence":[103],"error":[107,191],"were":[108],"investigated":[109],"finite":[111],"element":[112],"simulation.":[113],"performance":[115],"was":[120,133,157],"tested":[121],"dedicated":[124],"platform":[125],"ensure":[127],"stable":[128],"measurements.":[129],"calibrated":[134],"method":[137,156],"proposed":[138,183],"for":[139,201],"sensitivity,":[140],"phase":[141],"shift,":[142],"spatial":[143],"position,":[144],"direction":[146],"deflection":[147],"angle":[148],"minimize":[150],"errors.":[152],"reconstruction":[155],"introduced":[158],"minimizing":[160],"difference":[162],"between":[163],"calculated":[167],"flux":[169],"density":[170],"stochastic":[173],"optimization":[174],"algorithm.":[175],"Simulation":[176],"experimental":[178],"results":[179],"demonstrate":[180],"that":[181],"can":[185],"accurately":[186],"with":[189],"an":[190],"less":[193],"than":[194],"2%":[195],"after":[196],"calibration,":[197],"highlighting":[198],"potential":[200],"monitoring":[204],"power":[207],"cables.":[208]},"counts_by_year":[{"year":2026,"cited_by_count":3}],"updated_date":"2026-07-15T18:14:33.161393","created_date":"2025-10-10T00:00:00"}
