{"id":"https://openalex.org/W4405599694","doi":"https://doi.org/10.1109/access.2024.3520250","title":"Research on Life Attenuation of Lithium-Ion Batteries Based on IC Curves and Voltage Hybrid Evaluation Algorithm","display_name":"Research on Life Attenuation of Lithium-Ion Batteries Based on IC Curves and Voltage Hybrid Evaluation Algorithm","publication_year":2024,"publication_date":"2024-12-19","ids":{"openalex":"https://openalex.org/W4405599694","doi":"https://doi.org/10.1109/access.2024.3520250"},"language":"en","primary_location":{"id":"doi:10.1109/access.2024.3520250","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3520250","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2024.3520250","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Xiaorong Huang","orcid":"https://orcid.org/0009-0005-0783-6008"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xiaorong Huang","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":"https://orcid.org/0009-0005-0783-6008","affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037998254","display_name":"Wanwei Wang","orcid":"https://orcid.org/0000-0002-3737-6795"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wanwei Wang","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108905419","display_name":"Zhijun Guo","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhijun Guo","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067753216","display_name":"Xiliang Dai","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiliang Dai","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022642030","display_name":"Maoquan Ye","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Maoquan Ye","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088971383","display_name":"D. Tian","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Danyu Tian","raw_affiliation_strings":["Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongguan Power Supply Bureau of Guangdong Power Grid Corporation, Dongguan, Guangdong, China","institution_ids":["https://openalex.org/I74872605"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I74872605"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.19,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.52081207,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"13","issue":null,"first_page":"58835","last_page":"58847"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.7394999861717224,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.7394999861717224,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.6323000192642212,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12111","display_name":"Industrial Vision Systems and Defect Detection","score":0.6035000085830688,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/attenuation","display_name":"Attenuation","score":0.7519495487213135},{"id":"https://openalex.org/keywords/lithium","display_name":"Lithium (medication)","score":0.5706909894943237},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5294304490089417},{"id":"https://openalex.org/keywords/ion","display_name":"Ion","score":0.5101171135902405},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5024023056030273},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4529390335083008},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4171478748321533},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.4007761776447296},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3435578942298889},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3292192220687866},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1443873643875122},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.132602721452713},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.05870005488395691}],"concepts":[{"id":"https://openalex.org/C184652730","wikidata":"https://www.wikidata.org/wiki/Q2357982","display_name":"Attenuation","level":2,"score":0.7519495487213135},{"id":"https://openalex.org/C2778541603","wikidata":"https://www.wikidata.org/wiki/Q152763","display_name":"Lithium (medication)","level":2,"score":0.5706909894943237},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5294304490089417},{"id":"https://openalex.org/C145148216","wikidata":"https://www.wikidata.org/wiki/Q36496","display_name":"Ion","level":2,"score":0.5101171135902405},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5024023056030273},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4529390335083008},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4171478748321533},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.4007761776447296},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3435578942298889},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3292192220687866},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1443873643875122},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.132602721452713},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.05870005488395691},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134018914","wikidata":"https://www.wikidata.org/wiki/Q162606","display_name":"Endocrinology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2024.3520250","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3520250","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:0edd1d470de7481cae5fb8aa7ec93f70","is_oa":true,"landing_page_url":"https://doaj.org/article/0edd1d470de7481cae5fb8aa7ec93f70","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 13, Pp 58835-58847 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2024.3520250","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3520250","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W2500303754","https://openalex.org/W2790625295","https://openalex.org/W2791494814","https://openalex.org/W2883525675","https://openalex.org/W2934286352","https://openalex.org/W2943460745","https://openalex.org/W2950735432","https://openalex.org/W2963691557","https://openalex.org/W3006793235","https://openalex.org/W3025337842","https://openalex.org/W3134677430","https://openalex.org/W3159194574","https://openalex.org/W3171559388","https://openalex.org/W3172812377","https://openalex.org/W3200306615","https://openalex.org/W3200771099","https://openalex.org/W4200091892","https://openalex.org/W4206604195","https://openalex.org/W4223621951","https://openalex.org/W4224947065","https://openalex.org/W4293148829","https://openalex.org/W4295789398","https://openalex.org/W4303427427","https://openalex.org/W4309531997","https://openalex.org/W4313251766","https://openalex.org/W4313475707","https://openalex.org/W4320479570","https://openalex.org/W4320526741","https://openalex.org/W4386356481"],"related_works":["https://openalex.org/W2062605435","https://openalex.org/W2273182195","https://openalex.org/W2186374051","https://openalex.org/W2377963109","https://openalex.org/W2022279172","https://openalex.org/W2352247021","https://openalex.org/W2145835458","https://openalex.org/W2059332403","https://openalex.org/W2066034608","https://openalex.org/W1990381203"],"abstract_inverted_index":{"Due":[0],"to":[1,32,42,79,94,152],"the":[2,20,35,43,88,100],"gradual":[3],"degradation":[4,40],"of":[5,14,22,38,46,103,128],"lithium":[6],"batteries":[7],"during":[8],"use,":[9],"simple":[10,141],"and":[11,48,69,142,157],"accurate":[12],"evaluation":[13,85,132],"their":[15],"performance":[16,28,105,155],"is":[17,56],"crucial":[18],"for":[19,146],"optimization":[21],"Battery":[23],"Management":[24],"Systems.":[25],"Traditional":[26],"battery":[27,39,81,104,148,154],"evaluations":[29],"often":[30],"struggle":[31],"accurately":[33],"reflect":[34],"actual":[36],"state":[37],"due":[41],"indistinct":[44],"features":[45],"voltage":[47,67,118],"current":[49],"data.":[50],"To":[51,83],"overcome":[52],"this":[53,120],"issue,":[54],"it":[55,107],"proposed":[57],"a":[58,71,113,126,140],"hybrid":[59],"input":[60,115],"method":[61,121],"that":[62],"combines":[63],"IC":[64],"curves":[65],"with":[66,117,131],"data,":[68,97,119],"employs":[70],"Long":[72],"Short-Term":[73],"Memory":[74],"(LSTM)":[75],"deep":[76],"learning":[77],"model":[78],"assess":[80],"degradation.":[82],"improve":[84],"accuracy,":[86],"utilized":[87],"LSTM":[89],"model,":[90],"leveraging":[91],"its":[92],"capability":[93],"process":[95],"time-series":[96],"effectively":[98],"capturing":[99],"dynamic":[101],"characteristics":[102],"as":[106],"changes":[108],"over":[109],"time.":[110],"By":[111],"integrating":[112],"mixed":[114],"approach":[116],"demonstrated":[122],"higher":[123],"accuracy":[124],"in":[125],"series":[127],"validation":[129],"tests,":[130],"precision":[133],"controlled":[134],"within":[135],"2%.":[136],"This":[137],"finding":[138],"offers":[139],"efficient":[143],"technical":[144],"solution":[145],"optimizing":[147],"management":[149,158],"systems,":[150],"promising":[151],"enhance":[153],"monitoring":[156],"processes.":[159]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-10-10T00:00:00"}
