{"id":"https://openalex.org/W4401691572","doi":"https://doi.org/10.1109/access.2024.3445658","title":"The Phase-to-Ground Fault Locating Method for the Wind Farm Transmission Line With the Single End Transient Information","display_name":"The Phase-to-Ground Fault Locating Method for the Wind Farm Transmission Line With the Single End Transient Information","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W4401691572","doi":"https://doi.org/10.1109/access.2024.3445658"},"language":"en","primary_location":{"id":"doi:10.1109/access.2024.3445658","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3445658","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2024.3445658","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103043671","display_name":"Jianan He","orcid":"https://orcid.org/0009-0000-0045-7164"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Jianan He","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039316741","display_name":"Niu Jian","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jian Niu","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5106730294","display_name":"Lei Li","orcid":"https://orcid.org/0000-0002-5950-1112"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Lei Li","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003651149","display_name":"Zibo Liu","orcid":"https://orcid.org/0000-0002-7547-6535"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zibo Liu","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100413181","display_name":"Haitao Liu","orcid":"https://orcid.org/0000-0003-1824-0304"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Haitao Liu","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084806807","display_name":"Ying Huang","orcid":"https://orcid.org/0000-0002-8172-9906"},"institutions":[{"id":"https://openalex.org/I4210142993","display_name":"China Shenhua Energy (China)","ror":"https://ror.org/046fag481","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210142993"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ying Huang","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Yinchuan Power Supply Company, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Yinchuan Power Supply Company, Yinchuan, China","institution_ids":["https://openalex.org/I4210142993"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073505819","display_name":"Xu Zhang","orcid":"https://orcid.org/0000-0002-0399-7411"},"institutions":[{"id":"https://openalex.org/I25757504","display_name":"China University of Mining and Technology","ror":"https://ror.org/01xt2dr21","country_code":"CN","type":"education","lineage":["https://openalex.org/I25757504"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xu Zhang","raw_affiliation_strings":["School of Mechanical and Electrical Engineering, China University of Mining and Technology-Beijing, Beijing, China"],"affiliations":[{"raw_affiliation_string":"School of Mechanical and Electrical Engineering, China University of Mining and Technology-Beijing, Beijing, China","institution_ids":["https://openalex.org/I25757504"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039117428","display_name":"E. Wang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Erqing Wang","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Electric Power Science Research Institute, Yinchuan, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109765926","display_name":"Meiling Luo","orcid":null},"institutions":[{"id":"https://openalex.org/I4210142993","display_name":"China Shenhua Energy (China)","ror":"https://ror.org/046fag481","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210142993"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Meiling Luo","raw_affiliation_strings":["State Grid Ningxia Electric Power Company Ltd., Yinchuan Power Supply Company, Yinchuan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Ningxia Electric Power Company Ltd., Yinchuan Power Supply Company, Yinchuan, China","institution_ids":["https://openalex.org/I4210142993"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":9,"corresponding_author_ids":["https://openalex.org/A5103043671"],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.0484,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.76924772,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"12","issue":null,"first_page":"115286","last_page":"115295"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.980400025844574,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7162893414497375},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.564932644367218},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5584951043128967},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5075775384902954},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4862607717514038},{"id":"https://openalex.org/keywords/transient-analysis","display_name":"Transient analysis","score":0.47156426310539246},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.44410043954849243},{"id":"https://openalex.org/keywords/single-phase","display_name":"Single phase","score":0.43773502111434937},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.4328802824020386},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.28311818838119507},{"id":"https://openalex.org/keywords/transient-response","display_name":"Transient response","score":0.2607371211051941},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.19503456354141235},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17799094319343567},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16509971022605896},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.14479276537895203},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07539916038513184}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7162893414497375},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.564932644367218},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5584951043128967},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5075775384902954},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4862607717514038},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.47156426310539246},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.44410043954849243},{"id":"https://openalex.org/C2989427145","wikidata":"https://www.wikidata.org/wiki/Q260295","display_name":"Single phase","level":2,"score":0.43773502111434937},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4328802824020386},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28311818838119507},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.2607371211051941},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.19503456354141235},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17799094319343567},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16509971022605896},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.14479276537895203},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07539916038513184},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2024.3445658","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3445658","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:54ef09d925904a1b892374d1b0f00b6b","is_oa":true,"landing_page_url":"https://doaj.org/article/54ef09d925904a1b892374d1b0f00b6b","pdf_url":null,"source":{"id":"https://openalex.org/S112646816","display_name":"SHILAP Revista de lepidopterolog\u00eda","issn_l":"0300-5267","issn":["0300-5267","2340-4078"],"is_oa":true,"is_in_doaj":true,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 12, Pp 115286-115295 (2024)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2024.3445658","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2024.3445658","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.7699999809265137,"id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G4089511224","display_name":null,"funder_award_id":"5229DK230003","funder_id":"https://openalex.org/F4320336296","funder_display_name":"State Grid Tianjin Electric Power Company"}],"funders":[{"id":"https://openalex.org/F4320336296","display_name":"State Grid Tianjin Electric Power Company","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1485380420","https://openalex.org/W2051000367","https://openalex.org/W2104184063","https://openalex.org/W2105269061","https://openalex.org/W2109822621","https://openalex.org/W2169738605","https://openalex.org/W2292996600","https://openalex.org/W2789350385","https://openalex.org/W3002449826","https://openalex.org/W3008699892","https://openalex.org/W3021158368","https://openalex.org/W3081100854","https://openalex.org/W3092507840","https://openalex.org/W3151015969","https://openalex.org/W3157752100","https://openalex.org/W4210353148","https://openalex.org/W4223995530","https://openalex.org/W4312886886","https://openalex.org/W4387350561","https://openalex.org/W4390098217","https://openalex.org/W4390098672","https://openalex.org/W4390120091"],"related_works":["https://openalex.org/W2758798772","https://openalex.org/W2081338125","https://openalex.org/W2376455116","https://openalex.org/W4406350055","https://openalex.org/W4239924455","https://openalex.org/W2001630809","https://openalex.org/W4244925124","https://openalex.org/W2377879397","https://openalex.org/W1577327694","https://openalex.org/W2887517211"],"abstract_inverted_index":{"The":[0,40,67,78,115],"fault":[1,59,65,85,95],"characteristics":[2],"of":[3,10,69,80,101],"large-capacity":[4],"wind":[5,31],"farms":[6],"affect":[7],"the":[8,52,64,70,84,97,102,119],"sensitivity":[9],"transmission-line":[11],"protection,":[12],"resulting":[13],"in":[14,37],"protection":[15],"devices":[16],"refusing":[17],"to":[18,62],"operate":[19],"or":[20,113],"mal-operate.":[21],"A":[22],"phase-to-ground":[23],"fault-locating":[24],"method":[25,42],"with":[26,51],"single-end":[27],"transient":[28,46],"information":[29],"for":[30],"farm":[32],"transmission":[33,53],"lines":[34],"was":[35,72],"proposed":[36,41,103,120],"this":[38],"study.":[39],"employs":[43],"a":[44],"time-domain":[45],"quantity":[47],"integration":[48],"equation":[49],"matrix":[50],"line":[54],"equivalent":[55],"resistance,":[56,86],"inductance,":[57],"and":[58,88,108,127],"path":[60],"resistance":[61],"solve":[63],"location.":[66],"effectiveness":[68],"scheme":[71],"evaluated":[73],"using":[74],"Real-Time":[75],"Lab":[76],"(RTLAB).":[77],"impact":[79],"factors":[81],"such":[82],"as":[83],"location,":[87],"distributed":[89],"capacitance":[90],"is":[91,105,110,122],"considered.":[92],"Under":[93],"different":[94],"locations,":[96],"distance":[98],"measurement":[99],"error":[100],"algorithm":[104,121],"within":[106],"3%,":[107],"there":[109],"no":[111],"rejection":[112],"mal-operation.":[114],"results":[116],"demonstrate":[117],"that":[118],"characterized":[123],"by":[124],"high":[125],"speed":[126],"reliability.":[128]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1}],"updated_date":"2025-12-26T23:08:49.675405","created_date":"2025-10-10T00:00:00"}