{"id":"https://openalex.org/W4389232917","doi":"https://doi.org/10.1109/access.2023.3338716","title":"A Hybrid Reliability Model Using Generalized Renewal Processes for Predictive Maintenance in Nuclear Power Plant Circulating Water Systems","display_name":"A Hybrid Reliability Model Using Generalized Renewal Processes for Predictive Maintenance in Nuclear Power Plant Circulating Water Systems","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4389232917","doi":"https://doi.org/10.1109/access.2023.3338716"},"language":"en","primary_location":{"id":"doi:10.1109/access.2023.3338716","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3338716","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10339300.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10339300.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009693037","display_name":"Ryan Spangler","orcid":"https://orcid.org/0009-0006-9357-3677"},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]},{"id":"https://openalex.org/I2800102766","display_name":"Idaho National Laboratory","ror":"https://ror.org/00ty2a548","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I2800102766","https://openalex.org/I2801818860"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ryan M. Spangler","raw_affiliation_strings":["Idaho National Laboratory, Idaho Falls, ID, USA","Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":"https://orcid.org/0009-0006-9357-3677","affiliations":[{"raw_affiliation_string":"Idaho National Laboratory, Idaho Falls, ID, USA","institution_ids":["https://openalex.org/I2800102766"]},{"raw_affiliation_string":"Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014550024","display_name":"Vivek Agarwal","orcid":"https://orcid.org/0000-0003-1334-0509"},"institutions":[{"id":"https://openalex.org/I2800102766","display_name":"Idaho National Laboratory","ror":"https://ror.org/00ty2a548","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I2800102766","https://openalex.org/I2801818860"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vivek Agarwal","raw_affiliation_strings":["Idaho National Laboratory, Idaho Falls, ID, USA"],"raw_orcid":"https://orcid.org/0000-0003-1334-0509","affiliations":[{"raw_affiliation_string":"Idaho National Laboratory, Idaho Falls, ID, USA","institution_ids":["https://openalex.org/I2800102766"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046464822","display_name":"Daniel G. Cole","orcid":"https://orcid.org/0000-0001-9541-3198"},"institutions":[{"id":"https://openalex.org/I170201317","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305","country_code":"US","type":"education","lineage":["https://openalex.org/I170201317"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Daniel G. Cole","raw_affiliation_strings":["Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA"],"raw_orcid":"https://orcid.org/0000-0001-9541-3198","affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I170201317"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.1275,"has_fulltext":true,"cited_by_count":8,"citation_normalized_percentile":{"value":0.74049152,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"11","issue":null,"first_page":"136726","last_page":"136740"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mean-time-between-failures","display_name":"Mean time between failures","score":0.8913833498954773},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7910816669464111},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.6791180372238159},{"id":"https://openalex.org/keywords/schedule","display_name":"Schedule","score":0.6541481614112854},{"id":"https://openalex.org/keywords/nuclear-power-plant","display_name":"Nuclear power plant","score":0.5482878088951111},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5439212322235107},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"Predictive maintenance","score":0.5377082824707031},{"id":"https://openalex.org/keywords/asset","display_name":"Asset (computer security)","score":0.4981060028076172},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.49543440341949463},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"Condition-based maintenance","score":0.43613743782043457},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.39038506150245667},{"id":"https://openalex.org/keywords/operations-research","display_name":"Operations research","score":0.365500271320343},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2984376549720764},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.275579571723938},{"id":"https://openalex.org/keywords/failure-rate","display_name":"Failure rate","score":0.22189030051231384},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.0902310311794281}],"concepts":[{"id":"https://openalex.org/C44154001","wikidata":"https://www.wikidata.org/wiki/Q754940","display_name":"Mean time between failures","level":3,"score":0.8913833498954773},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7910816669464111},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6791180372238159},{"id":"https://openalex.org/C68387754","wikidata":"https://www.wikidata.org/wiki/Q7271585","display_name":"Schedule","level":2,"score":0.6541481614112854},{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.5482878088951111},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5439212322235107},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.5377082824707031},{"id":"https://openalex.org/C76178495","wikidata":"https://www.wikidata.org/wiki/Q4808784","display_name":"Asset (computer security)","level":2,"score":0.4981060028076172},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.49543440341949463},{"id":"https://openalex.org/C2776907094","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Condition-based maintenance","level":2,"score":0.43613743782043457},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.39038506150245667},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.365500271320343},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2984376549720764},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.275579571723938},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.22189030051231384},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.0902310311794281},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":5,"locations":[{"id":"doi:10.1109/access.2023.3338716","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3338716","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10339300.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:7677b61be49147e584e7c1ec3e3a25d2","is_oa":true,"landing_page_url":"https://doaj.org/article/7677b61be49147e584e7c1ec3e3a25d2","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 11, Pp 136726-136740 (2023)","raw_type":"article"},{"id":"pmh:oai:osti.gov:2228411","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/2228411","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},{"id":"pmh:oai:osti.gov:2229830","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/2229830","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},{"id":"pmh:oai:osti.gov:2476247","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/2476247","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"doi:10.1109/access.2023.3338716","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3338716","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10339300.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.41999998688697815,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G2340302921","display_name":null,"funder_award_id":"DE-NE0008909","funder_id":"https://openalex.org/F4320332364","funder_display_name":"Office of Nuclear Energy"},{"id":"https://openalex.org/G3221568483","display_name":null,"funder_award_id":"31310018M0048","funder_id":"https://openalex.org/F4320308293","funder_display_name":"U.S. Nuclear Regulatory Commission"},{"id":"https://openalex.org/G3595626845","display_name":null,"funder_award_id":"DE-NE0008909","funder_id":"https://openalex.org/F4320337546","funder_display_name":"Nuclear Energy University Program"},{"id":"https://openalex.org/G8324277476","display_name":"NUCLEAR ENERGY UNIVERSITY PROGRAMS - NUCLEAR ENERGY UNIVERSITY PROGRAMS CONSOLIDATED INNOVATIVE NUCLEAR RESEARCH - \nUNIVERSITY OF PITTSBURGH","funder_award_id":"DENE0008909","funder_id":"https://openalex.org/F4320306084","funder_display_name":"U.S. Department of Energy"}],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"},{"id":"https://openalex.org/F4320308293","display_name":"U.S. Nuclear Regulatory Commission","ror":"https://ror.org/03nhmbj89"},{"id":"https://openalex.org/F4320310174","display_name":"University of Pittsburgh","ror":"https://ror.org/01an3r305"},{"id":"https://openalex.org/F4320332364","display_name":"Office of Nuclear Energy","ror":"https://ror.org/05tj7dm33"},{"id":"https://openalex.org/F4320337546","display_name":"Nuclear Energy University Program","ror":"https://ror.org/05tj7dm33"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4389232917.pdf","grobid_xml":"https://content.openalex.org/works/W4389232917.grobid-xml"},"referenced_works_count":42,"referenced_works":["https://openalex.org/W36686218","https://openalex.org/W108478551","https://openalex.org/W1494478641","https://openalex.org/W1506354754","https://openalex.org/W1535183290","https://openalex.org/W1645279274","https://openalex.org/W1969543203","https://openalex.org/W1990064670","https://openalex.org/W1995843873","https://openalex.org/W2015484611","https://openalex.org/W2026055266","https://openalex.org/W2048463175","https://openalex.org/W2058892149","https://openalex.org/W2069304502","https://openalex.org/W2107305576","https://openalex.org/W2131820609","https://openalex.org/W2141280997","https://openalex.org/W2141923571","https://openalex.org/W2316039394","https://openalex.org/W2802074788","https://openalex.org/W2809293408","https://openalex.org/W2912072773","https://openalex.org/W2943279412","https://openalex.org/W3046645857","https://openalex.org/W3118245494","https://openalex.org/W3126008567","https://openalex.org/W3217799852","https://openalex.org/W4212922449","https://openalex.org/W4249301259","https://openalex.org/W4294362938","https://openalex.org/W4295046711","https://openalex.org/W4300126076","https://openalex.org/W4301082185","https://openalex.org/W4310725959","https://openalex.org/W4312130573","https://openalex.org/W4312447289","https://openalex.org/W4364856178","https://openalex.org/W4376481070","https://openalex.org/W6632022884","https://openalex.org/W6678322642","https://openalex.org/W6789702216","https://openalex.org/W7039512123"],"related_works":["https://openalex.org/W2538175343","https://openalex.org/W4298110663","https://openalex.org/W2337958200","https://openalex.org/W2168011386","https://openalex.org/W2938469583","https://openalex.org/W2130822275","https://openalex.org/W4402668139","https://openalex.org/W1660921355","https://openalex.org/W4360585628","https://openalex.org/W2136937668"],"abstract_inverted_index":{"The":[0,216],"nuclear":[1,158,239],"industry\u2019s":[2],"economic":[3],"viability":[4],"is":[5],"challenged":[6],"by":[7,107,212],"significant":[8],"operations":[9,233],"and":[10,30,41,54,113,135,146,174,195,230,234],"maintenance":[11,15,21,45,114,144,200,235],"(O&M)":[12],"costs.":[13,43],"Although":[14],"strategies":[16,26],"are":[17],"often":[18],"risk-averse,":[19],"many":[20],"programs":[22],"rely":[23,92],"on":[24,93,156],"schedule-based":[25],"that":[27,63,97,203],"perform":[28],"repairs":[29,40,145],"replacements":[31],"regardless":[32],"of":[33,66,76,143,150,214,219],"the":[34,64,73,89,127,141,148,171,220,225,238],"asset\u2019s":[35],"condition,":[36],"leading":[37],"to":[38,139,170,176,183,193,227],"unnecessary":[39],"high":[42],"Predictive":[44],"can":[46,70,104,208],"help":[47,71],"alleviate":[48],"these":[49],"costs":[50,211,236],"through":[51],"condition":[52,109],"monitoring":[53],"risk-informed":[55,85],"decision":[56],"making.":[57],"In":[58,121],"this":[59],"article,":[60],"we":[61],"show":[62],"use":[65],"improved":[67,178,221],"reliability":[68,119,166,222],"models":[69,96,223],"reduce":[72,209,231],"total":[74],"cost":[75],"ownership":[77],"(TCO)":[78],"for":[79,198],"a":[80,117,153,157,164,184],"high-value":[81],"repairable":[82],"asset.":[83],"Current":[84],"methods":[86],"used":[87,192],"in":[88,237],"industry":[90],"today":[91],"mean-time-between-failure":[94],"(MTBF)":[95],"may":[98],"oversimplify":[99],"failure":[100],"likelihood":[101,149,179],"estimation.":[102],"Improvements":[103],"be":[105],"made":[106],"integrating":[108],"monitoring,":[110],"operational":[111],"history,":[112],"effectiveness":[115,142],"into":[116],"hybrid":[118,165],"model.":[120,186],"contrast":[122],"with":[123],"conventional":[124],"MTBF":[125,185],"methods,":[126],"generalized":[128],"renewal":[129],"process":[130],"uses":[131],"recurrent":[132],"event":[133],"analysis":[134],"historical":[136,172],"repair":[137],"data":[138,173],"quantify":[140],"estimate":[147],"failure.":[151],"During":[152],"case":[154],"study":[155],"power":[159,240],"plant\u2019s":[160],"circulating":[161],"water":[162],"system,":[163],"model":[167],"was":[168],"fitted":[169],"shown":[175],"have":[177],"estimations":[180],"when":[181],"compared":[182],"Monte":[187],"Carlo":[188],"simulations":[189],"were":[190],"then":[191],"simulate":[194],"compare":[196],"TCO":[197],"various":[199],"strategies,":[201],"showing":[202],"an":[204],"extended":[205],"replacement":[206],"interval":[207],"overall":[210,232],"upwards":[213],"10.7%.":[215],"successful":[217],"results":[218],"showcase":[224],"ability":[226],"aid":[228],"decision-making":[229],"industry.":[241]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2}],"updated_date":"2026-08-01T09:00:35.917206","created_date":"2025-10-10T00:00:00"}
